跳至主要内容
临床试验/NCT05615701
NCT05615701终止不适用

Image Quality of the EOSedge Radiographic System Versus a Standard Digital Radiographic (DR) System for Preoperative Assessment for Hip Replacement or Revision Surgery

University Hospital, Montpellier2 个研究点 分布在 1 个国家目标入组 97 人开始时间: 2022年11月16日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
终止
入组人数
97
试验地点
2
主要终点
Score of Image quality

研究概览

简要总结

EOSedge is a precise, low dose imaging system that delivers full body, high-quality images covering the full set of musculoskeletal and orthopedic exams.

The objective of the study is to evaluate the quality of the focused pelvis/hip X-ray images on EOSedge compared to those performed on DR (current practice) to perform a preoperative radiographic evaluation of hip implant, A sufficient image quality on focused X-ray images performed on EOSedge would allow (1) to avoid the passage on two different radiographic systems (saving time) (2) to reduce the patient's x-ray radiation dose

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patient 18 years of age or older
  • Came to the imaging department to perform a preoperative assessment for hip replacement or revision

排除标准

  • Patient under guardianship or curatorship
  • Patient participating in an interventional study
  • Patient unable to read and/or write

研究组 & 干预措施

EOSedge imaging

Other

Single arm study : All subjects include in the study underwent micro-dose EOS x-ray and digital radiography for radiographic evaluation of hip implant

干预措施: EOSedge imaging (Diagnostic Test)

结局指标

主要结局

Score of Image quality

时间窗: Day 0

Each criteria is quantitative and combined to obtain a final quantitative score : * Perfect reproduction = 2 / Moderate reproduction = 1 / Poor or uninterpretable reproduction = 0 * Artifacts ? = no or absence of periprosthetic material = 1; YES = 0 * X-ray image acceptable ? = Fully acceptable = 2; Acceptable only under limited clinical conditions = 1; Unacceptable (indicate why) = 0; OUTOCOME = FINAL SCORE 1. European C, Directorate-General for R, Innovation, Carmichael J, Moores B, Maccia C. Guide européen relatif aux critères de qualité des clichés de radiodiagnostic: Publications Office, 2000. 2. Kogon PL, Lumsden R. How do you critique your radiographs? The Journal of the Canadian Chiropractic Association. 1993; 37(4):230-232. 3. Cook JV, Kyriou JC, Pettet A, Fitzgerald MC, Shah K, Pablot SM. Key factors in the optimization of paediatric X-ray practice. The British journal of radiology. 2001; 74(887):1032-1040.

次要结局

  • Dosimetry(Day 0)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验