跳至主要内容
临床试验/NCT00148213
NCT00148213已完成不适用

Clinical Evaluation of a New Highly Sensitive Thyroglobulin Assay in Differentiated Thyroid Carcinoma

University Hospital Muenster1 个研究点 分布在 1 个国家目标入组 100 人开始时间: 2003年9月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
100
试验地点
1

研究概览

简要总结

Human thyroglobulin (Tg) is the most sensitive biochemical marker for recurrence of differentiated cancer (DTC), especially after the complete removal of thyroid tissue through surgery and radioiodine therapy (RIT).

Unfortunately, current assays for measuring Tg in blood samples are not sensitive enough to reliably measure Tg while patients are under thyroid hormone replacement therapy. Instead patients have to withdraw thyroid hormone for several weeks or receive costly injections of recombinant thyroid stimulating hormone (TSH) in order to raise Tg production by thyroid remnant and/or thyroid cancer cells so that it can be measured by current Tg assays. Other patients have antibodies against Tg that interfere in current immunoassays.

The purpose of the study was to characterize a new highly sensitive assay for measuring Tg in the serum in thyroid cancer patients both on thyroid hormone therapy and off therapy in comparison to the normal routine assay already in use at Münster University Hospital.

详细描述

Sera of 100 consecutive DTC patients after total thyroidectomy were to be collected at the Department of Nuclear Medicine both under TSH-suppression therapy and under endogenous TSH stimulation (TSH > 25 mU/l). All patients were staged by clinical examination, cervical ultrasound (7.5 MHz), I-131 whole-body scintigraphy and - where applicable - F18-FDG-PET. Written informed consent was obtained from all pts. Sera were taken in separation tubes without anticoagulants and stored at -20°C until analysis. Sera were allowed to come to room temperature prior to analysis.

Tg, TgR and TgAb concentrations were determined by fully automated two-site chemiluminescence immunoassays (CLIA; Nichols Advantage®; Nichols Institute Diagnostics, San Clemente, California). All 3 assays are based on the identical highly purified hTg material for calibration (Tg), recovery (TgR) and antigen (TgAb; biotinylated and acridinium ester labeled) for optimum comparability of test results.

In addition, Tg and TgR was measured by a fully automated two-site TRACE immunoassay (BRAHMS Kryptor®, Brahms AG, Hennigsdorf, Germany) and TSH with a 3rd-generation CLIA assay (TSH-3, Advia Centaur, Bayer Corporation).

研究设计

研究类型
Observational
时间视角
Other

入排标准

年龄范围
0 Years 至 —(Child, Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • histological diagnosis of differentiated thyroid carcinoma
  • total or near total thyroidectomy
  • informed consent

排除标准

  • no informed consent

研究者

发起方
University Hospital Muenster
申办方类型
Other

研究点 (1)

Loading locations...