Real-time Diagnosis of Serum LECT 2 in Patient With Liver Cancer Using Electronic Antibody Sensor (e- Ab Sensor)
试验速览
- 阶段
- 不适用
- 入组人数
- 80
- 试验地点
- 2
- 主要终点
- The performance of e- Ab sensor
研究概览
简要总结
To develop a real-time diagnostic technique with e- Ab sensor for specific LECT2 detection in clinical specimens of Hepatocellular carcinoma (HCC) patients, the investigators conduct a prospective clinical study. In comparison with results from direct sequencing of LECT2, the investigators evaluate the performance of e- Ab sensor, including reproducibility, sensitivity, specificity, and cross-reaction. With such technique, the investigators can obtain LECT2 information of HCC patients in cost-saving and time-saving way and can offer more individualized treatment for our patients.
详细描述
Hepatocellular carcinoma (HCC) is one of the most common types of cancer in the world. High cancer recurrence is still the major cause of death of HCC patients. The major poor prognostic factors included vascular invasion, high α-FP, large tumor size, or tumor satellitosis, etc. Among the various literature reports with multivariate analysis, vascular invasion of the tumor is the major contribution of high recurrence and poor survival. Therefore, identifying differentially expressed genes between vascular-invasion and non-vascular invasion of HCCs is important.
After suppression subtractive hybridization and microarray experiments, the investigators identified 20 differentially-expressed genes between vascular-invasive, and non-vascular invasive HCCs. One of the most interesting gene is leukocyte cell-derived chemotaxin 2 (LECT2). Further evaluation of the role of LECT2 on HCCs, the investigators found (1) Higher invasiveness, the lower of LECT2 gene expression in the HCC cell lines. (2) Conditioned medium with high LECT2 content will inhibit HCC invasion. (3) The invasion ability decreased in LECT2-overexpression hepatoma cell line. (4) In transendothelial cell migration assay, the investigators could observed invasion ability increased when LECT2 was knockdown in HCC cell line. (5) The lower expression of LECT2 gene in human HCCs correlate with higher tumor stage, early recurrence, and poor prognosis. (6) In vivo experiments revealed LECT2 can inhibit the ability of intravasation or metastatic ability of HCC.
Electrosensing antibody probing system (e- Ab sensor), which was developed for the rapid and sensitive detection of hapten, proteins, or viral antigen in medical samples, will be used for analyzing the interaction kinetics between specific anti- LECT2 and its antigen (LECT2 with liver cancer) present in the specimens of patients with liver cancer. The system incorporates the use of engineered semiconductive antibodies or virus in vertical and lateral chip (eAbchip) or lateral flow through (eAbsignal) formats. In electrosensing antibody probing, semiconductive antibodies are bound as a suitable electrosensing probe, which specifically and selectively binds targeted molecules (i.e. specific LECT2) in the test specimens. From assessment of the electric signature of semiconductive mutation-specific anti-LECT2 antibodies, the eABprobe could offer sensitive detection and precise quantification of specific LECT2.
To develop a real-time diagnostic technique with e- Ab sensor for specific LECT2 detection in clinical specimens of HCC patients, the investigators conduct a prospective clinical study. The investigators evaluate the performance of e- Ab sensor, including reproducibility, sensitivity, specificity, and cross-reaction. With such technique, the investigators can obtain LECT2 information of HCC patients in cost-saving and time-saving way and can offer more individualized treatment for our patients.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Diagnostic
- 盲法
- None
入排标准
- 年龄范围
- 20 Years 至 75 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •The patients with liver cancer.
- •The patients without liver cancer.
排除标准
- •Inmates, aboriginal peoples, pregnant women, mental patients, students, subordinates and other vulnerable groups.
- •Patients with malignant tumors.
- •Patients will be excluded if they couldn't sign the consent.
结局指标
主要结局
The performance of e- Ab sensor
时间窗: 1 Day
In comparison with results from direct concentration of LECT2, we evaluate the performance of e- Ab sensor, including reproducibility, sensitivity, specificity, and cross-reaction.
次要结局
未报告次要终点