临床试验/NCT04722250
NCT04722250进行中(未招募)不适用

SMall Annuli Randomized To Evolut™ or SAPIEN™ Trial

Medtronic Cardiovascular92 个研究点 分布在 13 个国家目标入组 1,103 人开始时间: 2021年4月2日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
进行中(未招募)
发起方
入组人数
1,103
试验地点
92
主要终点
Mortality, Disabling Stroke or Heart Failure Rehospitalization

研究概览

简要总结

The purpose of this trial is to generate clinical evidence on valve safety and performance of self-expanding (SE) versus balloon-expandable (BE) transcatheter aortic valve replacement (TAVR) in subjects with a small aortic annulus and symptomatic severe native aortic stenosis.

Additionally, a stress echocardiography sub-study will be conducted as part of the SMART Trial at select sites. The purpose of the sub-study is to evaluate performance of SE versus BE TAVR in subjects with a small aortic annulus and symptomatic severe native aortic stenosis after undergoing exercise stress echocardiographic testing.

详细描述

This is a prospective, multi-center, international, randomized controlled, post-market trial.

The primary objectives of the trial are to demonstrate clinical non-inferiority and hemodynamic superiority of the Evolut PRO/PRO+/FX System when compared to subjects treated with the SAPIEN 3/3 Ultra System at 12 months post-procedure.

Subjects will be randomized on a 1:1 basis to receive TAVR with either a Medtronic SE Transcatheter Aortic Valve (TAV) or an Edwards BE Transcatheter Heart Valve (THV). Data will be collected at pre- and post-procedure, at discharge, at 30 days, and once a year until the 5-year follow-up is completed.

Product Names:

  • Medtronic Evolut PRO and Evolut PRO+ TAV Systems, Evolut FX System (Commercially available in the United States and may be used upon commercial availability in Canada.)
  • Edwards SAPIEN 3 and SAPIEN 3 Ultra THV Systems

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Heart Team agrees that the subject is deemed symptomatic and is a candidate for transcatheter aortic valve replacement (TAVR)
  • Subject has a predicted risk of operative mortality < 15% as determined by the local Heart Team
  • Subject has severe aortic stenosis as determined by transthoracic echocardiography (TTE) at rest
  • Subject has a small aortic annulus as determined by Multi-detector computed tomography (MDCT)
  • Subject's anatomy is appropriate for both Medtronic Evolut PRO/PRO+/FX TAV and Edwards SAPIEN 3/3 Ultra TAV
  • Subject's anatomy is suitable for TAVR via transfemoral vessel access
  • Subject and the treating physician agree that the subject will return for all required post-procedure follow-up visits

排除标准

  • Estimated life expectancy of fewer than 2 years
  • Multivessel coronary artery disease with a Syntax score >32 and/or unprotected left main coronary artery(Syntax score calculation is not required for patients with history of previous revascularization if repeat revascularization is not planned).
  • Participating in another trial that may influence the outcome of this trial
  • Need for an emergent procedure for any reason
  • Contraindicated for treatment with the Evolut PRO/PRO+/FX and Edwards SAPIEN 3/3 Ultra TAV in accordance with the Instructions for Use
  • Other medical, social, or psychological conditions that in the opinion of the Investigator precludes the subject from appropriate consent or adherence to the protocol required follow-up exams
  • Pregnant, nursing, or planning to be pregnant
  • Subject is less than the legal age of consent, legally incompetent, unable to provide his/her own informed consent, or otherwise vulnerable
  • Subject has an active COVID-19 infection or relevant history of COVID-19
  • Previous aortic valve replacement

研究组 & 干预措施

Medtronic Self-Expanding TAV

Experimental

Subjects will be randomized on a 1:1 basis to receive TAVR with either a Medtronic SE TAV or an Edwards BE THV.

干预措施: Medtronic Evolut PRO, Evolut PRO+ or Evolut FX (where commercially available) TAV Systems (Device)

Edwards Balloon-Expandable THV

Experimental

Subjects will be randomized on a 1:1 basis to receive TAVR with either a Medtronic SE TAV or an Edwards BE THV.

干预措施: Edwards SAPIEN 3 or SAPIEN 3 Ultra THV Systems (Device)

结局指标

主要结局

Mortality, Disabling Stroke or Heart Failure Rehospitalization

时间窗: 12 months

Percentage of participants with all-cause mortality, disabling stroke, or heart failure rehospitalization.

Bioprosthetic Valve Dysfunction (BVD)

时间窗: 12 months

Percentage of participants with BVD as determined by echocardiography (hemodynamic structural valve dysfunction (aortic valve no longer works properly as measured by hemodynamic mean gradient ≥ 20mmHg), non-structural valve dysfunction (severe prosthesis-patient mismatch (valve is too small) and/or ≥ moderate total aortic regurgitation (backward flow of blood)), thrombosis (formation of a blood clot), endocarditis (inflammation of the endocardium - the inner lining of the heart chambers and valves), or aortic valve re-intervention (a follow-up procedure to fix or replace the aortic prosthetic valve))

次要结局

  • Percentage of Participants With Hemodynamic Structural Valve Dysfunction (HSVD)(12 months)
  • Hemodynamic Mean Gradient as Continuous Variable(12 months)
  • Effective Orifice Area (EOA) as a Continuous Variable(12 months)
  • Rate of Moderate or Severe Prothesis-patient Mismatch (PPM)(30 days)
  • Percentage of Participants With BVD in Female Subjects(12 months)

研究者

发起方
Medtronic Cardiovascular
申办方类型
Industry
责任方
Sponsor