临床试验/NCT00360139
NCT00360139撤回4 期

A Phase IV, Prospective, Non-Blinded, Non-Randomized, Single-Center Clinical Trial to Determine the Longevity, Duration, and Volume-Correcting Efficacy of Sculptra™ Dermal Filler for the Correction of Contour Deformities Caused by Lipoatrophy

Dermatology Cosmetic Laser Medical Associates of La Jolla, Inc.2 个研究点 分布在 1 个国家目标入组 15 人开始时间: 2006年8月3日最近更新:
适应症

试验速览

阶段
4 期
状态
撤回
发起方
入组人数
15
试验地点
2
主要终点
Volume correction and longevity of correction

研究概览

简要总结

Lipoatrophy is a condition that affects certain individuals, most commonly those who are infected with the HIV virus. Lipoatrophy however can also affect individuals who suffer from recurrent systemic infections, those who have a weakened immune system, or certain patients who suffer from cancer or receive chemotherapeutics. In contrast, lipoatrophy can sometimes be present in individuals who are perfectly healthy but have genetically predisposing factors that can contribute to facial emaciation or lipoatrophy.

The function of injectable fillers for the treatment of dermal contour deformities is to smooth dermal depressions formed by the loss of volume. These often elastic contour fillers (also known as soft tissue augmentation devices) can correct hollowness around the eyes, add fullness to thin lips, balance a disproportionate face or correct topographical anomalies.

This study aims to:

  • Objectively measure the improvement of contour-deformities after Sculptra™ injection from baseline to study closure by utilizing the Primos™ photographic/topographical measuring system.
  • Evaluate the efficacy, longevity and duration of volume-correction in subjects which are both HIV positive and HIV negative.
  • Assess the safety of Scupltra™ dermal filler when used to correct volume deformities caused by lipoatrophy in subjects that are HIV negative.

详细描述

Soft tissue fillers are used to temporarily fill facial lines and wrinkles and augment contour deformities. There are a variety of soft tissue fillers available.

Sculptra™ has been used to correct dermal atrophy in both the HIV and non-HIV populations. Almost all clinical trials have used a visual assessment scale to grade correction as well as persistence. Recently, dermal ultrasound has been used to provide an objective measurement of dermal thickening, but the ultrasound procedure measures only a fraction of the dermis and is subject to a high degree of variability because of the difficulty in measuring the same area. Our protocol utilizes the Primos ½ face system to produce a 3-dimensional evaluation of a large area. This will produce excellent reproducible results as well as outstanding photographs for patient demonstration.

Sculptra™ is an injectable implant that contains microparticles or poly-L-lactic acid, a biocompatible, biodegradable, synthetic polymer from the alpha-hydroxy-acid family. Sculptra™ is reconstituted prior to use by the addition of sterile water for injection, USP (SWFI) to form a sterile non-pyrogenic suspension.

Comparison:

Dermik's Vega Study - The Vega study was a 96-week, open-label, uncontrolled, single-center study to determine the treatment effects of Sculptra on the signs of lipoatrophy of the face in 50 patients infected with human immunodeficiency virus. Patients had a mean age of 45 years (range 33-58), 84% were Caucasian and 98% were male. All patients had little or no adipose tissue in cheek area at baseline, indicating severe facial lipoatrophy (mean adipose thickness of 0.5±0.7 mm, ranging from 0.0 to 2.1 mm).

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Bilateral lipoatrophy corresponding to a visual grade 2 or above in the attached lipoatrophy scale.
  • Available and willing to attend all follow-up visits.
  • Age > 18 years.
  • Able and willing to give informed consent.

排除标准

  • Known allergy or sensitivity to Sculptra™, suture material or any material that in the investigator's opinion may cause an allergic reaction.
  • The subject has received a soft tissue augmentation to the area to be treated within the last 6 months.
  • Subject is unwilling to forgo any cosmetic augmentation procedures for the duration of the study.
  • The subject has received autologous fat transfer in the last 6 months.
  • Subject is suffering from facial Kaposi's sarcoma.
  • The subject has active skin diseases or inflammation on or near the area of injection, such as psoriasis, herpes zoster, infection, or discoid lupus.
  • History of sensitivity to lidocaine.
  • Pregnant or nursing. (Premenopausal or nonsurgically sterile women must have a negative urine pregnancy test and must be using an adequate method of birth control.)
  • Subject has ever received an injection or implant of silicone in the area to be treated.
  • Subject is currently on any metabolic augmentation medications such as anabolic steroids.
  • Current use of anticoagulant therapy or has a history of hemorrhagic disorders.
  • History of connective tissue disease or other related disorder that in the investigator's opinion excludes the subject from the study.
  • Subject is involved in any other research study involving an investigational product, or has concluded a study less than 30 days ago.
  • The subject is suffering from any medical condition or complication that in the investigator's opinion places the subject at risk by participating in the study.

结局指标

主要结局

Volume correction and longevity of correction

时间窗: at 12 and 24 months

次要结局

  • Safety in non-HIV positive subjects