Utilized Scan Body Technique For Jaw Relation Registration And Face Scan Alignment (Triple Function Scan Body)
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 15
- 试验地点
- 1
- 主要终点
- percentage of consistency in simultaneous contacts in maximal intercuspal position
研究概览
简要总结
A triple function scan Body were done on healed dental implant, thus simplifying the workflow for full arch cases and reducing the number of visits to only 3 visits. In this technique, scan bodies were utilized for implant position scanning, facial scan alignment and as stoppers for jaw relation capturing as scan bodies were used as stoppers for jaw relation registration.
详细描述
The present article describes a novel technique for merging a patient's facial scan with implant scan body and in the same time utilizing the same scan body for recording the jaw relation in only one visit. As a result, a facially driven full-arch implant-supported interim prosthesis can be fabricated first followed by the final restoration in a simplified approach. The aim of this study is to determine whether there is a difference between virtual design and reality using scan body technique (triple function scan body which reflects the accuracy of the scanning protocol. The null hypothesis established that there was consistency between the virtual design and prosthesis in patient's mouth. The scan body was placed in the edentulous arch in the jaw scan step so that bite registration would be easier for the intraoral scanner (IOS) in order to be able to capture both the teeth of the antagonist and part of the scan body in the edentulous jaw simultaneously.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 22 Years 至 45 Years(Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •patient had at least one edentulous arch with at least 5 osseointegrated implants with healing period of 3 months after surgical procedure.
- •Implants are stable
- •Systemically free
排除标准
- •Uncooperative patients
研究组 & 干预措施
Triple Function Scan Body
Full arch implants were placed, a triple function scan Body and thus simplifying the workflow for full arch cases and reducing the number of visits to only 3 visits. Scan bodies were utilized for implant position scanning, facial scan alignment and as stoppers for jaw relation capturing as scan bodies were used as stoppers for jaw relation registration.
干预措施: Triple function scan body (Procedure)
结局指标
主要结局
percentage of consistency in simultaneous contacts in maximal intercuspal position
时间窗: 2 months following the final prosthesis
At 2 months follow up after final prostheses delivery, a frontal photo was taken and an intra oral scan was made for each patient in order to assess the degree of consistency between initial virtual design and reality using Exocad Software, The intra oral Scan of the full arch restoration is inserted into Exocad Software and the interocclusal contacts for all teeth were detected, classifying them in a dichotomy variable (yes/no) contact or not per tooth.
次要结局
未报告次要终点