跳至主要内容
临床试验/NCT02826343
NCT02826343已完成早期 1 期

Xe129 Magnetic Resonance Imaging of the Lung: A New Technology to Assess Treatment for COPD

University of Virginia1 个研究点 分布在 1 个国家目标入组 30 人开始时间: 2016年5月1日最近更新:
适应症
干预措施
相关药物

试验速览

阶段
早期 1 期
状态
已完成
入组人数
30
试验地点
1
主要终点
Improvement in pulmonary airflow physiology detected by Xenon129 MRI

研究概览

简要总结

First, the investigators will image patients with hyperpolarized xenon (Xe) magnetic resonance imaging (MRI) to develop the technique of hyperpolarized xenon MRI at the University of Virginia (UVA). Magnetic Resonance (MR) sequences will need to be developed and optimized for the equipment at UVA. These sequences will need to be evaluated in healthy adults for comparison with results obtained and in adults with lung diseases to optimize the sequences for the detection and evaluation of lung diseases. The MR pulse sequences need to be optimized for the parameters of a human MR coil and the gas exchange characteristics in healthy and diseased lungs.

Second, the investigators propose to exploit the power of Xe129 MRI as a diagnostic tool to monitor therapeutic responses of a combination inhaler, Advair, which contains a long-acting beta-adrenoceptor agonist (LABA) and an inhaled corticosteroid (ICS) - two major classes of the current COPD therapeutics. The investigators will characterize the functional changes of the lungs with COPD at baseline, and investigate the responses of the lungs to the treatment after a three-month trial. Also the investigators will compare corresponding results obtained by Xe129 dissolved phase (DP) MRI to the results obtained by gadolinium-based dynamic contrast-enhanced perfusion MRI (perfusion MRI) and high resolution computed tomography (HRCT) of the lung to indirectly validate the Xe129 DP MRI technique. The investigators anticipate that the results from this project will greatly improve the investigators understanding of the lung functional responses of COPD subjects to current therapeutics. Also, the investigators expect that this project will provide evidence to consider Xe129 MRI as a diagnostic strategy to assess and monitor therapeutic responses of existing and new pharmaceuticals, and thus Xe129 MRI will stimulate development of novel therapies for COPD in the future

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 85 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Subjects should be at their clinical baseline on the day of imaging
  • Subjects must be clinically stable in order to participate in the study
  • Smoking history >10 pack years
  • Subjects must not be currently taking Advair or have taken it within 4 weeks prior to screening
  • No subject will be withdrawn from Advair to participate in this study
  • The subjects with COPD will be categorized according to the Global Initiative for Chronic Obstructive Lung Disease (GOLD) COPD severity classification:
  • Class 1: forced expiratory volume at one second (FEV1)/forced vital capacity (FVC) < 70 and FEV1 > 80% predicted;
  • Class 2: FEV1/FVC < 70 and 50% < FEV1 < 80% predicted;
  • Class 3: FEV1/FVC < 70 and 30% < FEV1 < 50% predicted;
  • Class 4: FEV1/FVC < 70 and FEV1 < 30% predicted

排除标准

  • Continuous oxygen use at home
  • Blood oxygen saturation of 92% less than as measured by pulse oximetry on the day of imaging
  • FEV1 percent predicted less than 25%
  • Pregnancy or lactation
  • Claustrophobia, inner ear implants, aneurysm or other surgical clips, metal foreign bodies in eye, pacemaker or other contraindication to MR scanning
  • Subjects with any implanted device that cannot be verified as MRI compliant will be excluded.
  • Chest circumference greater than that of the xenon MR and/or helium coil. The circumference of the coil is approximately 42 inches.
  • History of congenital cardiac disease, chronic renal failure, or cirrhosis.
  • Inability to understand simple instructions or to hold still for approximately 10 seconds.
  • History of respiratory infection within 2 weeks prior to the MR scan
  • History of myocardial infarction (MI) , stroke and/or poorly controlled hypertension.
  • Known hypersensitivity to albuterol or any of its components, or levalbuterol
  • Glomerular filtration rate (GFR) < 60 ml/min/1.73 m2 or known hypersensitivity to Gd-contrast agents based on a serum creatinine drawn within 30 days of the MRI
  • Acute kidney injury
  • History of paraproteinemia syndromes such as multiple myeloma
  • Hepatorenal syndrome
  • Liver transplant

研究组 & 干预措施

COPD Advair

Other

Subjects will undergo hyperpolarized xenon MRI with perfusion imaging, before and after a 90 day course of Adair.

All subjects belong to one arm and will receive same treatment. Then they are compared at baseline and 3 month post intervention (described below) for within same-subject changes.

Subjects will be administered with

  1. Hyperpolarized Xenon129 inhalation during MRI twice (at baseline and post 3 month Advair)
  2. Gadolinium intravenous contrast during MRI twice (at baseline and post 3 month Advair)
  3. Advair diskus: strength 250mcg/50mcg, one puff twice a day for 3 months.

干预措施: Xenon129 MRI imaging (Drug)

COPD Advair

Other

Subjects will undergo hyperpolarized xenon MRI with perfusion imaging, before and after a 90 day course of Adair.

All subjects belong to one arm and will receive same treatment. Then they are compared at baseline and 3 month post intervention (described below) for within same-subject changes.

Subjects will be administered with

  1. Hyperpolarized Xenon129 inhalation during MRI twice (at baseline and post 3 month Advair)
  2. Gadolinium intravenous contrast during MRI twice (at baseline and post 3 month Advair)
  3. Advair diskus: strength 250mcg/50mcg, one puff twice a day for 3 months.

干预措施: Gadolinium MRI (Drug)

COPD Advair

Other

Subjects will undergo hyperpolarized xenon MRI with perfusion imaging, before and after a 90 day course of Adair.

All subjects belong to one arm and will receive same treatment. Then they are compared at baseline and 3 month post intervention (described below) for within same-subject changes.

Subjects will be administered with

  1. Hyperpolarized Xenon129 inhalation during MRI twice (at baseline and post 3 month Advair)
  2. Gadolinium intravenous contrast during MRI twice (at baseline and post 3 month Advair)
  3. Advair diskus: strength 250mcg/50mcg, one puff twice a day for 3 months.

干预措施: Advair (250mcg/50mcg) one puff twice a day (Drug)

结局指标

主要结局

Improvement in pulmonary airflow physiology detected by Xenon129 MRI

时间窗: From baseline to 3 month post treatment with Advair

MRI will determine anticipated improvement in patients' airflow limitation correlation ventilation defect.

Improvement in pulmonary gas exchange physiology detected by Xenon129 MRI

时间窗: From baseline to 3 month post treatment with Advair

Dissolved phase Xe129 of the MRI will determine anticipated improvement in patients' gas exchange capacity in lung tissues correlating with tissue damage caused by COPD.

次要结局

  • Improvement in clinical pulmonary function test(From baseline to 3 month post treatment with Advair)
  • GOLD Stage(From baseline to 3 month post treatment with Advair)
  • St. George's Respiratory Questionnaire(From baseline to 3 month post treatment with Advair)
  • Transition Dyspnea Index(From baseline to 3 month post treatment with Advair)
  • Baseline Dyspnea Index(From baseline to 3 month post treatment with Advair)
  • Chronic Respiratory Questionnaire(From baseline to 3 month post treatment with Advair)
  • BODE score(From baseline to 3 month post treatment with Advair)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Y. Michael Shim, MD

Associate Professor

University of Virginia

研究点 (1)

Loading locations...

相似试验