An Open-label, Single-arm, Phase 1 Study Examining the Safety and Efficacy of Fibrin Sealant Plus Silver Microparticles to Prevent Incisional Hernias (HiP_1 Trial) Following Abdominal Surgery

Hobart Harris0 个研究点开始时间: 2019年1月最近更新:
适应症
干预措施
相关药物

试验速览

阶段
1 期
状态
撤回
发起方
主要终点
Wound Occurrences

研究概览

简要总结

Incisional hernias are a frequent consequence of abdominal surgery. Current clinical efforts are primarily focused on improving repair materials and surgical techniques to correct these hernias instead of the optimal solution: prevention.

A product called MYOSEAL is currently being developed to prevent hernia formation after abdominal surgery by using fibrin tissue sealant and silver particles to prophylactically enhance the early wound healing of myofascial incisions. The purpose of this phase 1 study is to examine the safety of applying MYOSEAL immediately after abdominal wall suture closure in patients undergoing abdominal surgery. The investigators expect that applying this product to sutured myofascial incisions will increase collagen formation in the wound and thus prevent the formation of incisional hernias.

详细描述

Hernias are areas of weakness in the muscle of the abdomen and commonly develop after people have had abdominal surgery. This area of weakness often turns into a bulge or protrusion that can increase in size over time, interfere with the intestines and make it difficult for people to work or exercise. Many people undergo surgery to fix their hernia. Unfortunately, the operations to repair the hernia frequently fail and the hernia returns. The investigators are developing a material to help the body heal after abdominal surgery and thereby prevent incisional hernias for forming in the first place. This study is the first step in testing this new material in patients and whether it is safe to use. This study will include patients having all types of abdominal surgeries.

The test material is called MYOSEAL; a combination of a tissue sealant called TISSEEL® (Baxter Biosurgery, Deerfield, IL) plus small particles of metallic silver (<250µ, American Elements, Los Angeles, CA). TISSEEL is made from naturally occurring blood proteins and has been approved by the Food and Drug Administration (FDA) for use in surgery since 1998. But, TISSEEL has not been approved to prevent incisional hernias after abdominal surgery. The silver particles are not approved by FDA, but are thought to be generally safe in the way they will be used. This study hopes to learn how to help the body better heal after abdominal surgery.

At the conclusion of a laparotomy, 4-6 pairs of stainless steel clips (large Horizon® titanium clips, Teleflex Medical, Research Triangle Park, NC) will be attached opposite each other and equally spaced to the edges of the sutured myofascial incision, followed by the application of MYOSEAL to the sutured myofascial incision before closure of the skin. Study participants will be examined at 1 day, 1 month, 3 months, and 6 months after surgery. The primary endpoints include wound occurrences, including wound infections, seromas, and hematomas and postoperative complications through 6 months following surgery. The secondary endpoint is the incisional hernia rate at 1 month as determined by the distance between the metal clips marking the myofascial edges using calipers and a plain abdominal radiograph.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Prevention
盲法
None

入排标准

年龄范围
21 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • The patient is undergoing an abdominal operation requiring an incision ≥10-cm in length;
  • Negative pregnancy test;
  • No allergic, religious or ethical objections to fibrin tissue sealants (human blood proteins), aprotinin or metallic silver;
  • Signed informed consent to take part in the study

排除标准

  • Lactating women;
  • Patients who are unable to commit to the follow evaluations over 6 months;
  • Severe malnutrition (serum albumin <2.0);
  • Use of an investigational agent within 1 month prior to study enrollment and/or planned during this study;
  • Immunocompromised patients, as evidenced by: administration of high doses of corticosteroids (i.e. doses ≥ 1.5 mg/kg/day of prednisone or equivalent) within 72 hours before study enrollment; status post solid organ transplant or bone marrow transplant AND experiencing acute organ rejection or bone marrow failure or rejection; evidence of neutropenia (absolute neutrophil count ≤ 500 cells/mm3 (≤ 500 x 106 cells/L); immunosuppression secondary to immunomodulatory medications (e.g. cyclosporin, azathioprine, OKT3), chemotherapy or radiation therapy within 90 days before study enrollment; known AIDS; any disease sufficiently advanced to suppress resistance to infection (including, but not limited to leukemia, lymphoma or hypogammaglobulinemia); administration of immunoglobulin of G-CSF within 90 days before study enrollment;
  • Presence of an underlying disease/injury with life expectancy less than two years and/or severe underlying disease that would preclude study entry (e.g. known malignancy).

研究组 & 干预措施

Myoseal

Experimental

The fibrin sealant and silver microparticles are sprayed onto the surface of the sutured myofascial incision following abdominal surgery.

干预措施: Fibrin Sealant (Drug)

Myoseal

Experimental

The fibrin sealant and silver microparticles are sprayed onto the surface of the sutured myofascial incision following abdominal surgery.

干预措施: Silver Microparticles (Drug)

结局指标

主要结局

Wound Occurrences

时间窗: 6 months after surgery

Wound events include surgical site infections as well as seromas/hematomas.

Post-operative Complications

时间窗: 6 months after surgery

Post-operative complications include urinary tract infection and sepsis.

次要结局

  • Incisional Hernia(1 month after surgery)

研究者

发起方
Hobart Harris
申办方类型
Other
责任方
Sponsor Investigator
主要研究者

Hobart Harris

Professor & Chief, Division of General Surgery

University of California, San Francisco