跳至主要内容
临床试验/NCT04162080
NCT04162080已完成不适用

Observational Study in Kayak Polo Athletes.

University of Valencia2 个研究点 分布在 1 个国家目标入组 40 人开始时间: 2019年12月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
40
试验地点
2
主要终点
Weight and percentage of fat mass

研究概览

简要总结

Kayak polo (KP) is a sport that, as a breviary, can be defined as the union between water polo and canoeing. The objective of this study is to compare anthropometric parameters, joint assessment, strength and functional capacity between two groups of KP players from the Valencian Community. The sample will be divided into a Sub21 group and a Senior group. Anthropometric variables (body mass index [BMI], percentage of fat mass, waist - hip index [CHF], body perimeters ...), shoulder assessment (Range of movement in rotations, Scapular Dyskinesis Test [SDT]) will be assessed. glenohumeral instability ...), hip assessment (modified Thomas test), strength (Hand Grip Strength test and upper limb thrust), lower limb power (Counter Movement Jump [CMJ]) and functional capacity (1 'push-ups for limbs upper and 1 'Sit-to-Stand test for lower limbs).

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Cross Sectional

入排标准

年龄范围
16 Years 至 30 Years(Child, Adult)
性别
All
接受健康志愿者

入选标准

  • kayak polo athletes

排除标准

  • other sports
  • current injuries the previous 6 months

结局指标

主要结局

Weight and percentage of fat mass

时间窗: 1 day

A scale - bioimpedaniometer model Tanita BF350 Anazyliser body composition will be used. Through acoustic bioimpedance, the four sensors of this scale that come into contact with the soles of the feet serve to assess the body composition of the individual, once the data on: size, age and sex have been entered.

Skin fold

时间窗: 1 day

An 842-SK-001 polymer pyrometer of the Quirumed brand will be used. This one has an accuracy of 2mm and will be used for the measurement of skin folds of adipose tissue. Specifically, the tricipital fatty fold (PGT) will be measured

Shoulder ROM

时间窗: 1 day

To obtain the ROM in shoulder rotations, a conventional analog polymer goniometer of the Saehan brand Grip model will be used, with an accuracy of 2 degrees. External rotation (RE) and internal rotation (RI) of the dominant upper limb will be assessed.

次要结局

  • Glenohumeral apprehension test(1 day)
  • Scapular dyskinesia(1 day)
  • Clamping force in upper limbs(1 day)
  • Functional capacity in lower limbs(1 day)
  • Impingement subacromial (SAPS)(1 day)
  • Movement Jump (CMJ) or Countermovement Jump(1 day)
  • Shortening in hip flexion(1 day)
  • Thrust force in upper limbs(1 day)
  • Functional ability in upper limbs(1 day)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

GEMMA V ESPÍ LÓPEZ, PhD

Principal Investigator

University of Valencia

研究点 (2)

Loading locations...

相似试验