Ventilator Hyperinflation With Increase of Inspiratory Time on Respiratory Mechanics: A Randomized Crossover Trial
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 38
- 试验地点
- 2
- 主要终点
- Static compliance of respiratory system
研究概览
简要总结
The investigators hypothesis is that the adjustment of the inspiratory time may optimize the distribution of ventilation and increase tidal volume, producing potential therapeutic effects on the displacement of secretions and respiratory mechanics. The objective of this study was To evaluate the effects of hyperinflation with the ventilator associated with increased inspiratory time on respiratory mechanics.
详细描述
A randomized crossover clinical trial was conducted with 38 mechanically ventilated patients with pulmonary infection. The order of hyperinflation or control (without changes in parameters) was randomized. Hyperinflation was performed for 5 minutes in the controlled pressure ventilation mode, with progressive increases of 5cmH2O until reaching a maximum pressure of 35cmH2O, maintaining PEEP. After reaching 35cmH2O, the inspiratory time and respiratory rate were adjusted so that the inspiratory and expiratory flows reached the baseline, respectively. Static compliance (Cest, sr), total resistance (Rsr) and airway resistance (Rva), slow pressure drop (ΔP2) and peak expiratory flow (PEF) were assessed before (PRÉ), immediately after the maneuver (POSSimed) and after aspiration (POSPasp). Two-way ANOVA was used for repeated measurements with Tukey post-test, considering a significant p <0.05.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Crossover
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 80 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patients under mechanical ventilation for more than 48h
- •Mucus hypersecretion (defined as the need for suctioning < 2-h intervals)
排除标准
- •Severe bronchospasm,
- •Positive end expiratory pressure > 10cmH2O,
- •PaO2-FiO2 relationship < 150,
- •Mean arterial pressure < 60mmHg,
- •Pleural effusion or pneumothorax undrained,
- •Bronchopleural or tracheoesophageal fistula,
- •Decompensated congestive heart failure.
研究组 & 干预措施
mechanical ventilator hyperinflation
The VHI maneuver with inspiratory time adjustment was performed in the pressure controlled ventilation mode (PCV). The inspiratory pressure was increased gradually every 5 cmH2O until reaching a maximum pressure of 35 cmH2O, according to the tolerance of the patient determined by the absence of cough. PEEP remained unchanged throughout the study. After reaching a maximum pressure of 35 cmH2O (PCV + PEEP level), the inspiratory time was gradually increased until the inspiratory flow reached the baseline. Concomitantly, the respiratory rate was decreased to allow the expiratory flow also to reach the baseline, to avoid self-PEEP. The maneuver was performed for 5 min, followed by tracheal aspiration.
干预措施: Ventilator hyperinflation (Other)
Control
To perform the control (CTRL), the patients were only positioned and aspirated, without alteration in ventilatory parameters.
结局指标
主要结局
Static compliance of respiratory system
时间窗: Baseline (before), immediately after VHI and five minutes after aspiration
Compliance was assessed through the occlusion maneuver at the end of inspiration, considering tidal volume, plateau pressure and PEEP. Three measurements were taken at each moment, the mean being used.
Total Resistance of respiratory system
时间窗: Baseline (before), immediately after VHI and five minutes after aspiration
The total resistance of the respiratory system was evaluated through the occlusion maneuver at the end of the inspiration, considering the resistive pressure, measured by the difference between the maximum plateau pressure. Three measurements were taken at each moment, the mean being used.
Airway Resistance
时间窗: Baseline (before), immediately after VHI and five minutes after aspiration
The airway resistance was assessed by means of the occlusion maneuver at the end of the inspiration, considering the rapid fall of the pressure immediately after the occlusion, measured by the difference between the maximum pressure and P1. Three measurements were taken at each moment, the mean being used.
Peak expiratory flow
时间窗: Baseline (before), immediately after VHI and five minutes after aspiration
The peak expiratory flow was evaluated through passive expiration, being considered the greatest value of the flow in the expiratory phase.
次要结局
未报告次要终点
研究者
Luciano Matos Chicayban
Chefe do Laboratório de Análise de Disfunções Pneumofuncionais (LADPF)
Brazilian Institute of Higher Education of Censa
