跳至主要内容
临床试验/NCT05446922
NCT05446922尚未招募不适用

National, Multicentre, Prospective, Interventional Study of the Variability of Cerebral MRI Diffusion Parameters by Using a Patented Normalization Process Versus no Use of Normalization Process

Braintale0 个研究点目标入组 60 人开始时间: 2023年9月1日最近更新:
适应症

试验速览

阶段
不适用
状态
尚未招募
发起方
Braintale
入组人数
60
主要终点
Coefficients of Variation (%CV) of FA measurement

研究概览

简要总结

BrainTale has developed a standardization approach based on averaging measurements in predefined brain regions of interest and use of reference data acquired from healthy volunteers under conditions (MRI machine, acquisition protocol) identical to those used for the examination of the patient. The present study is intended to support the normalization step on healthy volunteers in clinical centres that will be equipped with the BrainTale medical device software dedicated to clinical routine practice and to assess, through a multicentre study, the impact of this normalization step on the variability of the MRI diffusion parameters. The data collected will support characterization and modelisation of the variability to explore further biais corrections methods. The study will be conducted by neuroradiologists of the neuroradiology departments of five clinical centres in France.

详细描述

Advances in medical imaging have made it possible, from the 1990s, to be able to visualize structural microlesions of the brain thanks to post-processing of the Magnetic Resonance Imaging (MRI) data acquired by the sequence using the diffusion tensor. Mathematical models such as the diffusion tensor have made it possible to quantify in each of the volumetric units of the brain (voxels) measurements correlated to the microstructure of neuronal axons such as the Fractional Anisotropy (FA), the Mean Diffusivity (MD), the Radial Diffusivity (RD) or the Axial Diffusivity (AD). These measurements thus make it possible to quantify the microstructural alterations.

However, the use of Diffusion Tensor Imaging (DTI) technology has limitations and currently, there is no "gold-standard" to validate diffusion measurements, which are currently dependent on acquisition protocols, post-processing software and observers.

To make these diffusion parameters usable in a clinical context, BrainTale has developed a standardization approach based on averaging measurements in predefined brain regions of interest and use of reference data acquired from healthy volunteers under conditions (MRI machine, acquisition protocol) identical to those used for the examination of the patient. This process requires the acquisition of 10 healthy volunteers to calibrate a new MRI protocol, which greatly limits access to the technology in clinical routine and limits the potential technological evolutions of the acquisition.

The study aims to assess the impact of a patented normalization process on the interindividual variability of Fractional Anisotropy (FA) measurements derived from cerebral Diffusion Tensor Imaging (DTI) acquisitions.

A total of 60 healthy volunteers will be included. One or two acquisition will be performed during a single on-site visit in order to collect diffusion parameters outcome data for further analyses (with or without normalization process).

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Other
盲法
None

入排标准

年龄范围
18 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Male or female aged 18 up to 80 years old
  • Covered by a healthcare insurance
  • Agreeing to be informed about any incidental finding discovered on brain MRI
  • Written informed consent form signed

排除标准

  • History of brain pathology, cognitive or psychiatric disorder
  • Any contraindication * for undergoing brain MRI
  • Subject refusing to participate or having expressed refusal to data collection/processing or unable to give his/her agreement to participate
  • Vulnerable subject (i.e. pregnant or breast-feeding woman, child, subject under curatorship or deprived of liberty)
  • contraindications to MRI include: pacemaker, neural stimulator, intraocular or intracerebral device, cochlear implant, MR-incompatible prosthetic heart valves, any implant with metallic, ferromagnetic or electrically conductive parts, any metal in the body which cannot be removed, claustrophobia.

结局指标

主要结局

Coefficients of Variation (%CV) of FA measurement

时间窗: Day 1

Percentage Coefficients of Variation (%CV) of FA measurements obtained from QC-passed DTI sequences before and after application of the normalization process.

次要结局

  • Coefficients of Variation (%CV) of AD measurement(Day 1)
  • Coefficients of Variation (%CV) of MD measurement(Day 1)
  • Coefficients of Variation (%CV) of RD measurement(Day 1)

研究者

发起方
Braintale
申办方类型
Industry
责任方
Sponsor

相似试验