Use of a Non-invasive Bio-impedance Cardiac Monitor, ICON™, to Detect and Trend Hemodynamic Variables During Dexmedetomidine Sedation in Children Undergoing Pulmonary Function Testing

Boston Children's Hospital0 个研究点开始时间: 2017年12月最近更新:
适应症

试验速览

阶段
不适用
状态
撤回
主要终点
Changes in heart rate

研究概览

简要总结

To collect and analyze the physiologic data of the ICON™ during dexmedetomidine (DEX) sedation for neonatal pulmonary function testing. The ICON™ is a noninvasive physiological monitor which uses respiratory impedance to follow systemic vascular resistance (SVR), heart rate, cardiac index and stroke index.

详细描述

Traditionally the measurements of cardiac indices and hemodynamic variables require invasive monitors such as pulmonary thermodilution catheters and transesophageal Doppler echocardiography. In recent years, electrical cardiometry has been used for the non-invasive determination of stroke volume, cardiac output, and other hemodynamic parameters in adults, children, and neonates. Electrical cardiometry has been validated against "gold standard" methods such as thermodilution and is a proprietary method trademarked by Cardiotronic, Inc. (La Jolla, CA). Cardiotronic markets the ICON™. It is FDA-approved for use in pediatric and adult patients, is currently used for clinical purposes in the BCH MSICU at 11 South.

The ICON™ is a comprehensive, standalone hemodynamic monitor, which provides a complete hemodynamic monitoring system that provides user-defined hemodynamic parameters. It provides a continuous trend of cardiac output and stroke volume associated with rapid changes in vital signs with minimal risk to the patient.

The ICON™ monitor has been used in Boston Children's Hospital to determine the hemodynamic changes in children aged 1 month to 18 years of age who received dexmedetomidine sedation for CT and Nuclear Medicine.

Dexmedetomidine (DEX) has been found to be an effective drug in the pediatric population in both the intensive care unit and for procedures in Radiology. In a recent study, DEX caused bradycardia (3%), hypotension (9%) and hypertension (8%) in pediatric critical care patients. Intravenously administrated sedation. DEX will be delivered as per the DEX order set used for non-painful procedures in the radiology department. As an alpha 2 adrenergic agonist, DEX produces hemodynamic changes to blood pressure and heart rate. To precisely follow the trend of complex changes in systemic vascular resistance, cardiac output and stroke volume during DEX administration, would ideally be with invasive intravascular monitors which would not be warranted in pediatric sedation procedures. However, a minimal risk non-invasive cardiac output monitor such as the ICON can measure, detect, and trend these physiological changes in the neonates and infants who are receiving DEX for pulmonary function tests.

Children with certain lung conditions undergo pulmonary function tests (PFT) which are currently being performed using chloral hydrate administered by the responsible and sedation credentialed pulmonologist (Dr. Lawrence Rhein). Chloral hydrate is inconsistent and unreliable in producing adequate sedation for a successful PFT study. Sedation physicians from the BCH Department of Anesthesia have agreed to provide sedation for these patients with dexmedetomidine (DEX), using the same approved protocols that are being used in the BCH Department of Radiology for non-painful imaging studies.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Prospective

入排标准

年龄范围
1 Month 至 18 Months(Child)
性别
All
接受健康志愿者

入选标准

  • Patients who are 1-18 months of age, scheduled for pulmonary function testing and eligible for sedation with dexmedetomidine and whose family agree to participate in the study

排除标准

  • Patients with the following diagnoses are not medically appropriate to receive nursing administered sedation with dexmedetomidine:
  • Active, uncontrolled gastroesophageal reflux - an aspiration risk
  • Active, uncontrolled vomiting - an aspiration risk
  • Current (or within past 3 months) history of apnea requiring an apnea monitor
  • Active, current respiratory issues that are different from the baseline status (pneumonia, exacerbation of asthma, bronchiolitis, respiratory syncytial virus)
  • Unstable cardiac status (life threatening arrhythmias, abnormal cardiac anatomy, significant cardiac dysfunction)
  • Craniofacial anomaly, which could make it difficult to effectively establish a mask airway for positive pressure ventilation if needed
  • History of digoxin use
  • Moya-Moya disease
  • New-onset stroke
  • In addition, the following are contraindications to the use of the ICON™:
  • Pacemakers
  • Mitral or aorta valve dysfunction
  • Dextrocardia
  • Second or third degree heart block
  • Current diagnosis of cardiac, pulmonary, hepatic or renal failure
  • Current diagnosis of pulmonary masses/tumor/pleural effusions/pneumonia/edema
  • Pericardial effusion
  • Large implanted thoracic metallic devices (including orthodontic braces, spine rods, plates and screws)
  • Allergy to device standard BCH ECG electrodes (Vermed A 10061-SRT disposable prewired medical electrodes)

结局指标

主要结局

Changes in heart rate

时间窗: Up to 12 hours

The changes in heart rate from baseline, during the DEX administration and sedation and during recovery period (following discontinuation of the DEX) through time of discharge.

Changes in blood pressure

时间窗: Up to 12 hours

The changes in blood pressure from baseline, during the DEX administration and sedation and during recovery period (following discontinuation of the DEX) through time of discharge.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Keira Mason

Director, Radiology Anesthesia; Senior Associate in Perioperative Anesthesia, Associate Professor of Anaesthesia

Boston Children's Hospital

相似试验