临床试验/NCT06934876
NCT06934876招募中不适用

Waveform Capnography and Colorimetric Carbon Dioxide Detection During Tracheal Intubation of Critically Ill Adults

Brian Driver15 个研究点 分布在 1 个国家目标入组 2,092 人开始时间: 2025年4月21日最近更新:
适应症

试验速览

阶段
不适用
状态
招募中
发起方
入组人数
2,092
试验地点
15
主要终点
Sensitivity of the test of exhaled carbon dioxide to detect a endotracheal tube positioned in the trachea.

研究概览

简要总结

This study will compare the sensitivity and specificity of waveform capnography versus colorimetric carbon dioxide detection to identify tracheal placement of the endotracheal tube during intubation of critically ill adults.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patient is located in a participating unit (ED or ICU)
  • Patient is undergoing tracheal intubation.
  • The clinician intends to use an exhaled CO2 detection device to confirm tracheal placement of the tube.

排除标准

  • Patient is known to be a prisoner
  • Patient is known to be < 18 years old
  • A responsible clinician has determined that sole use of either waveform capnography or colorimetric testing is required for optimal care of the patient.

结局指标

主要结局

Sensitivity of the test of exhaled carbon dioxide to detect a endotracheal tube positioned in the trachea.

时间窗: From intubation until 7 breaths from the ventilator are delivered, approximately 1 minute

The primary endpoint is the sensitivity of each test (against the reference standard) to accurately detect the tube location within the trachea. The sensitivity of each CO2 detection method describes the probability that the CO2 detection method is consistent with a tube location in the trachea for a patient who has an endotracheal tube located inside the trachea.

Sensitivity of the test of exhaled carbon dioxide to detect a endotracheal tube positioned in the trachea.

时间窗: From intubation until 7 breaths from the ventilator are delivered, approximately 1 minute

The co-primary endpoints are the sensitivity and specificity of each test (against the reference standard) to accurately detect the tube location. The sensitivity of each CO2 detection method describes the probability that the CO2 detection method is consistent with a tube location in the trachea for a patient who has an endotracheal tube located inside the trachea. The co-primary outcomes are a direct comparison of the sensitivity and specificity between the two index tests using McNemar's test with a two-sided P value with a significance level of 0.05. The McNemar's test is well-suited to paired data where both diagnostic tests are applied to the same patients. We will also present the absolute between-group difference with 95% confidence intervals.

次要结局

  • Specificity of the test of exhaled carbon dioxide to detect a endotracheal tube positioned outside of the trachea.(From intubation until 7 breaths from the ventilator are delivered, approximately 1 minute)

研究者

发起方
Brian Driver
申办方类型
Other
责任方
Sponsor Investigator
主要研究者

Brian Driver

Co-Principal Investigator

Hennepin Healthcare Research Institute

研究点 (15)

Loading locations...