ACTRN12617000708358进行中(未招募)未知
Clinical Evaluation of the FluidVision Mongoose X Accommodating Intraocular Lens for Accommodation Restoration in Adults with Cataract
适应症
试验速览
- 阶段
- 未知
- 状态
- 进行中(未招募)
- 发起方
- PowerVision
- 入组人数
- 96
研究概览
简要总结
暂无简介。
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomised controlled trial
- 主要目的
- Treatment
- 盲法
- Blinded (masking used)
入排标准
- 年龄范围
- 50 Years 至 o limit(—)
- 性别
- All
入选标准
- •1. At least 50 years of age;
- •2. Willing and able to comply with schedule for follow-up visits;
- •3. Able to read and understand the Informed Consent Form and Patient Information materials;
- •4. Eligible for primary intraocular lens implantation for the correction of aphakia following cataract extraction
- •5. Corrected distance visual acuity is equal to or worse than 20/40 either with or without a glare source present OR presence of visually significant lens opacity;
- •6. Predicted corrected distance visual acuity in both eyes to be 20/32 or better after cataract removal and IOL implantation as determined by potential acuity meter (PAM) or other potential vision tests;
- •7. Less than or equal to 1.0 diopter (D) of preoperative or predicted post-operative corneal astigmatism;
- •8. Clear intraocular media other than cataract;
- •9. Preoperative central endothelial cell density of 2200 cells/mm2 or more;
- •10. Eligible for LASIK procedure or other corneal refraction correction procedure;
- •11. Willing to wear contact lenses and physically capable of wearing them per
- •investigator examination
- •12. Able to undergo second eye surgery within 14 days after the first eye surgery.
排除标准
- •1. Subject is a member of a vulnerable population as defined in ISO 14155;
- •2. Current use of medications that may affect accommodation;
- •3. Current or historic use of systemic medications that may confound the outcome or increase the risk to the subject;
- •4. Sensitivity to planned study medications;
- •5. Pregnant, lactating, or has another condition with associated fluctuation of hormones that could lead to refractive changes;
- •6. Has systemic disease that could increase the operative risk or confound the outcome;
- •7. Ocular conditions that may predispose for future complications (e.g. anterior segment pathology including potentially occludable angles, corneal dystrophy, ocular inflammation);
- •8. Monocular patient or significant permanent visual function loss in one eye;
- •9. Previous refractive, intraocular or corneal surgery in either eye;
- •10. Diagnosed degenerative visual disorders that are predicted to cause future corrected distance visual acuity worse than 20/32;
- •11. Conditions that increase the risk of zonular rupture during procedure;
- •12. Simultaneous participation in other ophthalmic drug or device clinical trial;
- •13. Baseline dilated pupil size less than 8 mm in diameter;
- •14. Anterior Chamber Depth (ACD) less than 2.8 mm, based on IOL Master;
- •15. Grade 4 cataract in either eye, as assessed per the Quick Reference Guide (QRG)-8 published by the American Optometric Association;
- •16. Subject has any other condition(s), disease(s) or habit(s) that would interfere with completion of the study and follow-up visits, increase the risk(s) of the cataract and/or IOL procedure, or in the physician’s judgement, would interfere with compliance to the study or adversely impact study outcomes.
- •17. Subject randomized to AIOL with ocular dimensions not within range of manufacturer’s fitting algorithm.
- •Intraoperative Exclusion Criteria
- •18. Do not have an intact capsulorhexis and posterior capsule at the time of cataract
- •extraction and lens implantation;
- •19. Floppy/weak zonules, incomplete zonules or zonular rupture during cataract
- •extraction;
- •20. Posterior capsules that are found to be thin, brittle or fibrosed;
- •21. Decentered capsulorhexis of >1.0 mm in relation to the limbus;
- •22. Posterior capsular opacity observed after cataract extraction;
- •23. Complicated cataract surgery that prevents attempted implantation of the (A)IOL.
- •Additional Intraoperative Exclusion Criteria for the FluidVision AIOL
- •24. Unable to attain and maintain a dilated pupil size =7 mm in diameter;
- •25. Capsulorhexis size of less than 6.0 mm or greater than 6.5 mm.
研究者
相似试验
暂停
不适用
Clinical Evaluation of the FluidVision Accommodating Intraocular Lensh25Senile cataractDRKS00005696PowerVision, Inc.115
已完成
Unknown
An Exploratory Study on the Diagnosis of Pulmonary Thromboembolism (PTE) Using Radwisp and Determination of Treatment Efficacyacute pulmonary thromboembolismJPRN-UMIN000052843ihon university itabashi hospital50
已完成
不适用
Clinical evaluation of newly developed, optical-fiber based FFR device, comparing with conventional FFR devise using piezo electric sensors.coronary artery disease patientsJPRN-UMIN000021502agoya University Graduate School of Medicine50
已完成
Unknown
Clinical study to assess a new rapid COVID-19 testDetection of SARS-CoV-2 virions in infected participantsInfections and InfestationsISRCTN53590069Paraytec (United Kingdom)125
撤回
2 期
Clinical Evaluation of the Edwards Lifesciences Monarc system for the treatment of Mitral Regurgitatioheartvalve dysfunctionmitralis regurgitation10046973NL-OMON33127Edwards Lifesciences SA10