Argus II Retinal Prosthesis System - Better Vision RP Study

Second Sight Medical Products6 个研究点 分布在 1 个国家开始时间: 2018年11月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
撤回
发起方
试验地点
6
主要终点
Adverse events

研究概览

简要总结

The study is conducted to evaluate the safety and benefit of the Argus II System in a selected patient population with advanced Retinitis Pigmentosa who have a measurable central residual visual field smaller than or equal to 5 degrees radius.

详细描述

The Argus II System is intended for use in blind patients with severe to profound retinitis pigmentosa with at least some light perception in the eye to be implanted.

The majority of RP patients still have some central vision even at a very late stage of the disease. This extremely restricted visual field is, however, highly disabling in daily life. The primary objective of this study is to evaluate the safety and benefit of the Argus II System in RP patients characterized as late stage with a central residual visual field smaller than or equal to 5 degrees radius . The electrode array will be placed in a para- to peri foveal location adjacent to the subject's residual visual field, thus increasing the total retinal area receptive to light.

Safety data will be monitored to ensure continued acceptability of risks to study subjects and visual function will be measured to evaluate the effectiveness of the system in this "better vision" RP population. In addition, effects on functional vision and quality of life will be assessed through the Functional Low-Vision Observer Rated Assessment (FLORA) and the National Eye Institute Visual Function Questionnaire (NEI-VFQ-25).

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
25 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Adults, age 25 years or older;
  • Diagnosed with advanced Retinitis Pigmentosa (including syndromic RP), Choroideremia, Leber's Congenital Amaurosis, or Rod-Cone disease;
  • A measurable central residual visual field of 5° radius or smaller in both eyes, as determined by Goldmann perimetry;
  • Visual acuity of 0.1 (1.0 logMAR) or worse in the eye to be implanted, as measured by ETDRS chart;
  • Previous history of useful form vision;
  • Provided written, informed consent to participate in the study.

排除标准

  • Ocular diseases or conditions that could prevent the Argus II implant from working (e.g., optic nerve disease, central retinal artery or vein occlusion, history of retinal detachment, trauma, etc.);
  • Ocular structures or conditions that could prevent the successful implantation of the Argus II Implant or adequate healing from surgery (e.g. extremely thin conjunctiva; axial length <20.5 mm or > 26 mm; corneal ulcers; choroidal neovascularization in the area of the intended tack location, etc.);
  • Pre-disposition to eye rubbing;
  • Any disease or condition that prevents understanding or communication of informed consent, study demands, and testing protocols, including:
  • cognitive decline including diagnosed forms of dementia and/or progressive neurologic disease,
  • psychiatric disease including diagnosed forms of depression;
  • does not speak a principal language associated with the region, and
  • deafness or selective frequency hearing loss that prevents hearing device alarms and alerts;
  • Pregnant or wish to become pregnant during the course of the study;
  • Participating in another investigational drug or device study that may conflict with the objectives, follow-up, or testing of this study;
  • Inability to tolerate general anaesthesia or the recommended antibiotic and steroid regimen associated with the implantation surgery;
  • Conditions likely to limit life to less than 1 year from the time of inclusion.

研究组 & 干预措施

Argus II

Experimental

Implantation of the Argus II Retinal Prosthesis in patients with advanced Retinitis Pigmentosa who have a measurable central residual visual field smaller than or equal to 5 degrees radius. The array will be placed parafoveally, adjacent to the preserved central visual field (i.e., "tunnel vision") in these subjects.

干预措施: Argus II Retinal Prosthesis (Device)

结局指标

主要结局

Adverse events

时间窗: 2 Years

The nature and number of adverse events in implanted subjects.

Visual field

时间窗: 2 Years

The effect of the Argus II System on visual field size, as measured by Goldmann perimetry

次要结局

  • Visual function(2 Years)
  • Quality of Life(2 Years)