The Radiation ProtEction for Dose RedUction in the Cardiac CathEter Lab Study: The REDUCE Trial
试验速览
- 阶段
- 不适用
- 状态
- 招募中
- 入组人数
- 100
- 试验地点
- 2
- 主要终点
- 1st Operator Eye radiation
研究概览
简要总结
Doctors and nurses who perform heart procedures using X-ray guidance are exposed to radiation, which can be harmful over time. This exposure increases the risk of certain health problems, including cancers, eye damage (cataracts), and DNA damage. Although protective lead clothing is used to reduce exposure, it is heavy, uncomfortable, and can cause muscle and joint problems for those who wear it daily.
A new radiation protection device, called RAMPART, may help reduce radiation exposure for heart specialists and their teams. It could also allow them to wear lighter protective gear-or none at all-making their work safer and more comfortable.
This study will compare the radiation levels received by doctors and nurses during heart procedures when using RAMPART versus standard protection. By doing so, we hope to find out if this new device can better protect medical teams from radiation, improving both their safety and well-being.
详细描述
Recent decades have seen major increases in x-ray guided procedures in interventional cardiology, radiology and vascular surgery. Exposure to ionising radiation is known to be an inherent risk and remains a serious and unresolved threat to the health of operators and their team. It is associated with an increased incidence of brain and blood cancers, cataracts, and recent mechanistic data indicates significantly increased DNA damage in those without leaded leg protection.
Although existing standard radiation protection measures somewhat reduces exposure, all cardiac catheter lab personnel still receive a certain dose of radiation and continue to accumulate lifetime exposure. Furthermore, leaded personal protective equipment is heavy, leads to orthopaedic complications, and detracts from operator comfort.
Novel radiation protection devices such as RAMPART may significantly reduce radiation doses to cardiac catheter lab personnel, and potentially allow the use of lighter lead, or no lead at all. In this study we aim to investigate if use of RAMPART significantly reduces radiation exposure, when compared with standard radiation protection. Standard coronary intervention procedures will be randomised to RAMPART or standard (radiation protection), and operators and Cath lab team doses will be compared.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Supportive Care
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •All procedures involving adult patients (>18 year of age)
- •Male or female patients
- •Planned to undergo either an elective or urgent coronary intervention procedure involving ionising radiation in the cardiac catheter lab, via the right and or left radial arteries.
排除标准
- •Procedures involving patients less than 18 years of age
- •Patients unable to give valid consent
- •Pregnancy
- •Femoral approach procedure
结局指标
主要结局
1st Operator Eye radiation
时间窗: 1) Periprocedural 2) Cumulative dose - through study completion, an average of 1 year
To assess the effect of using a new medical device (RAMPART) in reducing the amount of radiation the first operator is exposed to (at eye level) when performing coronary angiography or angioplasty. Measurement of radiation in µSv.
次要结局
- 1st Operator Chest / Groind radiation(1) Periprocedural 2) Cumulative dose - through study completion, an average of 1 year)
- 2nd Operator Radiation - all levels(1) Periprocedural 2) Cumulative dose - through study completion, an average of 1 year)
- 'Circulating Nurse' Radiation(1) Periprocedural 2) Cumulative dose - through study completion, an average of 1 year)
研究者
John Hung
Consultant Cardiologist, Chief Investigator
Liverpool Heart and Chest Hospital NHS Foundation Trust