Technical and Clinical Validation Study of a New Wireless Portable and Multi-Channel Surface EMG Device to Analyse Motor Unit Action Potentials
试验速览
- 阶段
- 不适用
- 状态
- 招募中
- 发起方
- Alain Kaelin
- 入组人数
- 70
- 试验地点
- 2
- 主要终点
- Technical and clinical assessment
研究概览
简要总结
Validation study designed to demonstrate the technical and clinical performance, and the safety of a new medical device in healthy volunteers and patients with myopathy or neuropathy. The medical device is the WPM-SEMG prototype designed for recording electrophysiological signals of muscles.
详细描述
The study consists of two parts:
- the first part concerns the technical validation of the prototype. It will enrol 10 healthy volunteers (Technical Validation Group).
- the second part concerns the clinical validation of the prototype in comparison with the gold standard, that is the needle-EMG. It will enrol 50 healthy volunteers (Clinical Validation Group), including also the 10 subjects of the Technical Validation Group, and 20 patients
Measurements will be done on 4 muscles with the WPM-SEMG device prototype using a rigid electrode matrix. For each muscle, the participant will execute some spontaneous motor activities and measurements will be taken on the muscle under tension (low, medium, and high) for a total of 12 measurements. Measurements will be repeated two times after a pause for a total of 24 acquisitions. For the group with myopathies an additional fifth muscle, not foreseen by the protocol, can be done if considered the clinical most affected muscle followingthe neurological examination.
A control intervention is done on the same subjects and consists in a needle-EMG which will be applied as for routine clinical practice on the same muscles used for the WPM-SEMG device prototype. Measurements will be taken for each muscles as for the rigid matrix.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Other
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- 未提供
排除标准
- 未提供
结局指标
主要结局
Technical and clinical assessment
时间窗: Intervention (day0)
Correlation between the properties of the final electrophysiological output identified from sEMG signals acquired with the WPM-SEMG device prototype and the properties of the final electrophysiological output identified from EMG signals acquired using needle EMG. \[Time Frame: Intervention (day0)\] The following properties will be extracted: Amplitude (microVolts), phases/turns (ratio), signal frequency (Hz) and duration (seconds).
次要结局
- Pain assessment(Intervention (day0))
研究者
Alain Kaelin
Prof.
Ente Ospedaliero Cantonale, Bellinzona