Reliability of Sensor Spacing for Near Infrared Spectroscopy in Traumatic Tibia Fractures: An Observational Study

Emory University1 个研究点 分布在 1 个国家目标入组 14 人开始时间: 2014年12月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
14
试验地点
1
主要终点
NIRS measurements as compared to clinical findings

研究概览

简要总结

This is a study intended to evaluate a non-invasive device that uses light to measure the amount of oxygen in the muscles of injured and non-injured legs in specific situations. The name of this technology is NIRS (near-infrared spectroscopy). The goal of this study is to collect the information necessary to understand the use of the NIRS monitoring system to diagnose and direct treatment decisions in case of complications sometimes experienced in traumatic tibia fracture, such as excessive swelling called acute compartment syndrome (ACS).

详细描述

This study seeks to further develop the use of NIRS technology in the diagnosis of acute compartment syndrome. NIRS values normally increase in traumatized legs compared to the contralateral uninjured leg or forearm, indicative of a hyperemic response. The investigators hopes to build upon the current knowledge and verify the ability to accurately detect ACS using two easily identified and accessible leg compartments, the anterior and superficial posterior utilizing the Nonin 7600 oximeter with the Sensor Model 8004CV. Additionally, since this device was originally designed with brain tissue in mind, the NIRS device will collect vital engineering data that will be used to validate the algorithm used to produce the oxygenation values in injured muscle tissue.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 65 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Unilateral leg injury
  • Enrolled within 48 hours of injury
  • Subjects with 'severe' leg injuries presenting at trauma center that meet at least one of the following from each group below:
  • Anatomic location:
  • Tibia/Fibula shaft fracture
  • Tibial plateau fracture (Schatzker III-VI)
  • High Energy Mechanism of Injury:
  • Fall from >8 foot height
  • Motor vehicle collision (> 15 mph)
  • Motor vehicle versus pedestrian accident
  • High velocity gunshot wound
  • Crush injury
  • Sport/recreation

排除标准

  • Application of NIRS monitoring would be an impediment to care
  • Known prior leg fractures, patient has already undergone fasciotomy of the injured leg prior to enrollment
  • History of peripheral vascular disease or concurrent lower extremity vascular injury/surgery
  • Admission for atraumatic medical reasons
  • Subject is unable to provide informed consent, or consent cannot be obtained from a legally authorized representative
  • Complete spinal cord injuries, bilateral upper extremity injuries, or amputation/mangled lower extremity
  • Patients who are in police custody at presentation to the hospital or who are pregnant
  • Patient has an open injury on the injured leg that is large enough that at least one NIRS sensor cannot be safely placed over the compartment
  • Bilateral leg injuries
  • Not able to be enrolled within 48 hours after injury

结局指标

主要结局

NIRS measurements as compared to clinical findings

时间窗: Participants will be followed for the duration of hospital stay, an expected average of 72 hours

Assess the accuracy of the Nonin 7600 oximeter with the Sensor Model 8004CV in the diagnosis of Acute Compartment Syndrome, using the "gold standard" criterion for ACS, which will be "clinical diagnosis". That is, all subjects undergoing fasciotomy for clinically diagnosed ACS will be considered to have ACS. NIRS values will be compared to clinical diagnosis to determine accuracy and threshold values.

次要结局

  • Accuracy of NIRS measurements compared to Intracompartmental pressure (ICP) measurements(Participants will be followed for the duration of hospital stay, an expected average of 72 hours)
  • Correlation between NIRS measurements between injured and uninjured extremity(Participants will be followed for the duration of hospital stay, an expected average of 72 hours)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

William Reisman

William Reisman MD

Emory University

研究点 (1)

Loading locations...

相似试验

Reliability of Sensor Spacing for NIRS in Traumatic... | 临床试验