跳至主要内容
临床试验/NCT06269367
NCT06269367已完成不适用

NewGait: A Low-Cost Rehabilitation System to Improve Post-Stroke Gait (Biomechanical Adaptations)

University of Michigan2 个研究点 分布在 1 个国家目标入组 20 人开始时间: 2024年4月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
20
试验地点
2
主要终点
Ankle Muscle Activation

研究概览

简要总结

An affordable and easy to use gait-assistive device for stroke survivors to use at home is yet to be developed. This study is intended to modify the current design of the NewGait device to specifically work for stroke survivors based on feedback from patients and clinicians. Consequently, conducting a short-term biomechanical gait study is planned to determine the usability and functionality of the NewGait device compared to other comparative devices.

详细描述

More than 795,000 individuals suffer from a stroke each year in the United States, making stroke a leading cause of adult disability in the United States and worldwide. More than half of stroke survivors exhibit reduced independence and functional mobility due to stroke-related gait impairments. Despite significant advancements in post-stroke medical care and rehabilitation, current treatments are not successful in optimally restoring gait function after stroke. It is well established that intense, repetitive task-oriented rehabilitation interventions are essential for inducing experience-dependent neuroplasticity (defined as the ability of the nervous system to adapt and optimize its resources through structural and functional changes)-which is a key factor for post-stroke gait recovery. Accordingly, new therapeutic approaches that rely on specialized gait training devices, such as treadmills, robotic devices, and exosuits have been developed. However, these devices are typically expensive, bulky, and not accessible for home use. Moreover, these devices often require uninterrupted power sources, which is a major barrier for rural communities in developing nations. While some lightweight and "low-cost" commercial devices exist, they are not often designed based on multi-user feedback and robust biomechanical data and their clinical utility have not been tested in stroke survivors, thereby limiting usability and effectiveness. Thus, there is a significant unmet clinical need for an effective, affordable, and portable gait mobility/rehabilitation device that is accessible for most stroke survivors. This Phase-I STTR pursues the following specific aims: (1) Identify an optimal NewGait design based on end-user feedback (design sprints) and musculoskeletal modeling to address the needs of stroke rehabilitation, (2) Refine the current prototype using data gathered from design sprints and think aloud technique and perform benchtop testing on the final prototype to validate durability, and (3) Examine short-term gait adaptations and clinical feasibility in stroke survivors by performing a comparative clinical feasibility study in stroke survivors to establish the clinical utility of the NewGait device in comparison with other similar devices. This trial registration is for the third aim only, as the first two aims do not follow under the definition of clinical trial. All devices tested are deemed to be 501(k) exempt devices. The successful completion of this Phase-I STTR will lay the foundation for an evidence-based low-cost gait rehabilitation system that could positively affect the lives of millions of stroke survivors living across the globe.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Treatment
盲法
None

入排标准

年龄范围
40 Years 至 75 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Unilateral cortical or subcortical stroke
  • Chronic stroke (≥ 6 months) At least 6 months following their first unilateral stroke
  • Able to walk independently with/without assistive devices for 5-10 mins (~150m)
  • No significant cognitive deficits as determined by the Mini Mental State Examination (MMSE) score (score≥ 22)

排除标准

  • Cerebellar stroke
  • Traumatic or vascular brain injury
  • History of unstable heart condition, uncontrolled diabetes/hypertension
  • History of a recent lower-extremity trauma or fracture
  • History of a recent significant orthopedic or neurological conditions that could limit walking ability (e.g., multiple sclerosis, total knee replacement)
  • Documented history of significant spatial neglect
  • ankle joint contractures or significant spasticity in the lower limbs
  • History of a recent Botulinum Toxin (Botox) injection to the lower-extremity muscles (≤ 3 months)
  • Pregnant or actively planning to become pregnant (self-reported)- Inability to communicate or unable to consent

结局指标

主要结局

Ankle Muscle Activation

时间窗: Up to 2 hours

Changes in ankle muscle activation of the leg muscles as measured using surface electromyography between the experimental (NewGait) and control conditions. Muscle activation ranges from 0 to no upper limit, and higher activation meant that the muscle was being used more. The baseline measure for the first device was taken immediately prior to the intervention. Participants then wore the first device, and the during-training measure was taken immediately. After this, participants received training with the device for about 15 minutes, following which, the device was removed, and the post-intervention measure was taken immediately for the first device. Participants then rested for 20-30 minutes. This entire process was repeated with the second device. All measures were obtained on the same day.

Gait Speed

时间窗: Up to 2 hours

Changes in gait speed (from baseline) as measured using the 10 Meter Walk Test between the experimental (NewGait) and control conditions. Participants were timed during the 10 Meter Walk Test to determine their self-selected gait speed while walking overground in a hallway. In this test, participants walked down a 14 meter walkway, and a stopwatch was used to time how long it took participants to cross the intermediate 10 meter distance. The baseline measure for the first device was taken immediately prior to the intervention. Participants then wore the first device, and the during-training measure was taken immediately. After this, participants received training with the device for about 15 minutes, following which, the device was removed and the post-intervention measure was taken immediately for the first device. Participants then rested for 20-30 minutes. This entire process was repeated with the second device. All measures were obtained on the same day.

次要结局

  • Changes in Paretic Leg Propulsive Force(Up to 2 hours)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Chandramouli Krishnan

Associate Professor of Physical Medicine and Rehabilitation

University of Michigan

研究点 (2)

Loading locations...

相似试验

NewGait: A Low-Cost Rehabilitation System to Improve... | 临床试验