NCT01765686已完成不适用

Randomized Controlled Trial Comparing the Utility of an Ultrasonic Coagulating Device (UCSD) With Electrothermal Bipolar Vessel Sealer (EBVS) in Thyroid Surgery.

National Cancer Centre, Singapore4 个研究点 分布在 1 个国家目标入组 100 人开始时间: 2012年12月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
100
试验地点
4
主要终点
Duration of Surgery

研究概览

简要总结

Energy devices are used routinely during thyroid surgery to aid surgical dissection and to stop bleeding. The newer generation energy devices have several advantages over older machines. The two most commonly used newer generation energy devices are the Harmonic scalpel and the Small Jaw bipolar device. Currently there has been no randomized controlled trial that compares both devices side to side. We aim to compare the effectiveness of these two newer generation energy devices in thyroid surgery.

详细描述

Energy devices are used routinely during thyroid surgery to aid surgical dissection and haemostasis. The newer generation energy devices have several advantages over older machines. First, the newer devices deliver more focussed thermal application and thus are less likely to cause collateral injury to surrounding healthy tissue. This is particularly relevant in thyroid surgery because the thyroid gland is in close proximity to vital nerves that control our airway and glands that regulate calcium metabolism. Secondly, the newer energy devices have multifunctional properties and are capable of sealing, blunt dissection, grasping and dividing tissue. This is advantageous in thyroid surgery as the operating field has many narrow areas within and the potential reduction in the exchange of instruments facilitates surgery.

Currently, two of these newer generation energy devices are available for use in Singapore General Hospital and National Cancer Centre Singapore. Both devices are similarly priced; one is based on an ultrasonic vibrating blade (UCSD) to cut and coagulate tissue while the other uses bipolar electrical energy and pressure to form a seal and a micro blade to divide the sealed tissue (EBVS). To date, clinical studies comparing both devices have only been done on animal models and focus on sealing times in animal blood vessels.

We aim to compare the effectiveness of these two newer generation energy devices in thyroid surgery by looking at the incidence of post surgical complications, post operative drainage as well as the ease of use as reflected in the operating time.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Double (Participant, Outcomes Assessor)

入排标准

年龄范围
21 Years 至 75 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Age 21-75
  • Histological confirmation of differentiated thyroid cancer requiring surgery, symptomatic goiters, thyroid nodules requiring histological analysis, or thyrotoxicosis poorly controlled my medication
  • Undergoing thyroid surgery

排除标准

  • Previous neck radiotherapy
  • Previous neck surgery
  • Patients with advanced disease that would require radical or modified neck dissection
  • Patients with lobe larger than 10 cm or nodule larger than 8 cm which requires extensive dissection that may confound the study
  • Patients with connective tissue diseases or chronic diseases on long-term medications that may interfere with wound healing such as steroids.
  • Patients with bleeding diatheses.

结局指标

主要结局

Duration of Surgery

时间窗: Day 1: Day of Surgery

Kife to skin time to closure time.

Bleeding

时间窗: Day 1 and on day of drain removal.

Measured blood loss during surgery including suction amount minus the irrigation fluid used as well as the number of gauzes. Drain amount is also recorded postoperatively

次要结局

  • Post op complications(Day 2)
  • Vocal chords on nasal scope inspection(Day 15 and up to 3-months post-op)
  • Ease of use(Day 1)