New AI-based Technologies for Even Safer and More Precise Nuclear Medicine

Azienda USL Reggio Emilia - IRCCS1 个研究点 分布在 1 个国家目标入组 1,500 人开始时间: 2021年7月30日最近更新:

试验速览

阶段
不适用
状态
招募中
发起方
入组人数
1,500
试验地点
1
主要终点
Characterization of new semi-quantitative metrics to detect extravasation events

研究概览

简要总结

The study aims to identify and predict radiopharmaceutical extravasation events using new semi-quantitative parameters and machine learning models. It involves dose rate measurements to develop metrics for real-time monitoring. It also investigates the correlation between extravasation and SUV correction in PET/CT diagnostics, providing an estimate of the correction factor necessary for accurate SUV evaluation in case of an extravasation event.

详细描述

This is a descriptive, observational, non-profit study aimed at detecting and predicting extravasation events during the administration of radiopharmaceuticals for diagnostic and therapeutic purposes in nuclear medicine. Extravasation can lead to local tissue damage and compromise the accuracy of semi-quantitative imaging parameters such as the Standardized Uptake Value (SUV), widely used in PET/CT for diagnosis, staging, and therapy response evaluation. Literature reports that extravasation may cause a 21-50% change in SUV, potentially leading to incorrect assessment of tumor response.

The study will use a CE-marked portable spectroscopic personal radiation detector (RadEye SPRD-ER, Thermo Fisher Scientific™), already validated in a previous Ethics Committee-approved study, to record dose-rate (DR) curves during radiopharmaceutical injections. Using these data, new dosimetric metrics will be developed to characterize correct, abnormal, and extravasation events. Machine learning (ML) algorithms will be trained on patient clinical data, injection metrics, and DR curves to classify injection events in real time and to estimate correction factors for SUV quantification. Monte Carlo simulations (MCNP code, anthropomorphic phantoms, and reconstructed patient geometries) will be performed to evaluate absorbed dose distributions in extravascular regions.

The project is structured into three phases:

Phase 1 (Data Acquisition & Analysis): Real-time monitoring with RadEye SPRD-ER, extraction of quantitative metrics (DRmax, DRmean, Δp, t*, Δt), development of ML classifiers and regression models for SUV correction.

Phase 2 (Monte Carlo Simulations): Activity and dose calibration, dose distribution modeling in extravascular tissues.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 90 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • patients undergoing PET/CT scans or therapeutic treatments with radiopharmaceuticals labelled with alpha or beta emitting nuclides

排除标准

  • patients whose clinical or psychological conditions do not allow for their involvement

结局指标

主要结局

Characterization of new semi-quantitative metrics to detect extravasation events

时间窗: During and immediately after radiopharmaceutical injection

Identification and validation of quantitative parameters derived from dose-rate (DR) curves capable of reliably distinguishing between normal injection, abnormal venous retention, and extravasation events. Metrics will be applicable to both therapeutic radiopharmaceuticals (α and β emitters) and diagnostic radiotracers (e.g., PET/CT)

次要结局

  • Correlation between extravasation severity and SUV alterations in nuclear medicine diagnostics(within 90 minutes after radiopharmaceutical administration)