跳至主要内容
临床试验/NCT05554263
NCT05554263已完成不适用

Comparison of Automated Control Anesthesia and Manual Control Anesthesia Methods İn Minimal Flow Anesthesia in the Mindray A9®

Sakarya University2 个研究点 分布在 1 个国家目标入组 80 人开始时间: 2022年9月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
80
试验地点
2
主要终点
ET-AA

研究概览

简要总结

With the introduction of technology into our lives, we come across two different anesthesia management modules in anesthesia machines. The first of these is the traditional method, the manual controlled anesthesia technique; the other is the automatic controlled anesthesia technique. In our daily practice, both anesthesia techniques can be used in patients who have undergone general anesthesia. These two techniques can be used in both high-flow anesthesia and low-flow anesthesia applications.

详细描述

In the manual technique, the inspired and exhaled gas concentrations are regulated by the anesthetists manually by the fresh gas flow during general anaesthesia. When administered manually, low-flow anesthesia requires the attention and time of the anesthesiologist, especially the difference between the gas concentrations set in the anesthesia machine and the respiratory system, and the delay between changes in fresh gas concentrations and the end tidal fraction (EtAA) of the anesthetic agent. The most important risks of manually controlled low-flow anesthesia are hypoxia and awareness that may occur due to low doses of inhaler anesthetic agents.

In the automatic controlled anesthesia technique, it is a method in which the values desired by the anesthetists during general anesthesia are determined at the beginning of anesthesia and automatically adjusted by the anesthesia device without any additional intervention. After intubation, anesthetists set 3 parameters on the anesthesia device: inspiratory or expiratory oxygen fraction (FiO2- End tidal O2 concentration), anesthetic agent concentration (MAC or End-tidal Anesthetic agent concentration) and fresh gas flow amount. With this method, it is aimed to provide safer and more stable anesthesia. In addition, it has been stated in many previous studies that automatic control anesthesia technique reduces anesthetic gas consumption and less anesthesiologist intervention is needed to reach target values.

In our study, we aimed to compare the safety, efficiency and cost aspects of automatic controlled anesthesia and manual control methods in achieving intraoperative target anesthetic and oxygen concentrations. We hypothesized that anesthesia applied with the end-tidal control method would have a lower cost, less workload, and similar anesthetic depth with the manual control method.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 75 Years(Adult, Older Adult)
性别
Female
接受健康志愿者

入选标准

  • Between 18-75 year-old
  • Will undergo gynecological operation
  • Expected surgery time (>1 hour)

排除标准

  • ❖ BMI >30
  • Chronic opioid use
  • Contraindication to any of the anesthetic agents to be used
  • Neurological disorders
  • Surgery lasting <1 hour

结局指标

主要结局

ET-AA

时间窗: 10 minutes

searching the time needed to reach the target end tidal anesthetic agent (ET-AA) concentration and the amount of anesthetic agent consumption

次要结局

  • target values(4 hours)

研究者

发起方
Sakarya University
申办方类型
Other
责任方
Principal Investigator
主要研究者

Rezan Şerefoğlu

Research assistant

Sakarya University

研究点 (2)

Loading locations...