Assessment of Regional Lungs Aeration Changes Examined by Impedance Tomography, Depending on the Drive Pressure Applied During High Frequency Jet Ventilation.
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 30
- 主要终点
- Lung aeration corresponding to each layer of the lungs.
研究概览
简要总结
The purpose of this study is attempt to establish optimum drive pressure of high frequency jet ventilation during rigid bronchoscopy to ensure good aeration of the lungs examined by electrical impedance tomography.
详细描述
The study was performed in the Department of Anaesthesiology and Intensive Therapy in Zabrze.
After application of eligibility criteria 30 patients were enrolled in a prospective, observational study. Each patient received an information about the study and the consent form to carry out the measurement procedures was obtained. The data about sex, age, weight, height, comorbidities, BMI were collected.
Patients were given premedication, midazolam (Sopodorm, ICN Polfa Rzeszow, Poland; doses: weight 80kg - 7.5 mg; weight 80-100kg - 15mg) on hour before projected surgery.
Upon arrival to the operating room patient's basic monitoring was provided: ECG (3 leads), heart rate, noninvasive measurement of blood pressure (NIBP), and pulse oximetry. At the same time, a belt with electrodes was put on a patient to monitor impedance tomography, then an automatical record of the basic parameters of regional lung ventilation was turned on.
The medications used for induction of anesthesia: fentanyl (Fentanyl WZF, Polfa Warsaw, Poland) at a dose of 2 g /kg bw i.v., propofol (Diprivan, AstraZeneca, PolskaPlofed Polpharma Poland) at a dose of 2 mg / kg bw, i.v. and to carry out an intubation - cis-atracurium (Nimbex, GlaxoSmithKine, UK) at dose of 0.15 mg /kg bw i.v. During rigid bronchoscopy maintenance of general anesthesia was achieved through the supply of intravenous propofol at a dose of 10 - 6 mg/kg bw/h.The high frequency jet ventilation (HFJV) was performed with proper respirator (Universal Jet Ventilator Monsoon DeLuxe ACUTRONIC Switzerland), using following ventilation parameters: f = 160-200 breaths / min, FiO2 (fraction of inspired oxygen) = 1, the DP (drive pressure) = 1.5-2.5 Atm. Simultaneously, patients were monitored using a PulmoVista 500 Dräger device and aeration of the lungs examined by electrical impedance tomography were observed in a monitor.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Older than 18
- •Obtained written consent form to participate in research
- •Patients qualified for rigid bronchoscopy procedure
排除标准
- •Absence of the written consent to participate in research
- •Undergoing urgent treatment
结局指标
主要结局
Lung aeration corresponding to each layer of the lungs.
时间窗: 10 minutes
The numerical values indicating the percentage of total increased resistance corresponding to each layer of the lungs (ROI - region of interests) that were collected in 15-seconds intervals.
次要结局
未报告次要终点
研究者
Katarzyna Rybczyk
Principal Investigator
Silesian University of Medicine