A Case Collection Study for Digital Breast Tomosynthesis (DBT) Using the Senographe Essential

GE Healthcare1 个研究点 分布在 1 个国家目标入组 80 人开始时间: 2013年8月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
GE Healthcare
入组人数
80
试验地点
1
主要终点
DBT in Senographe Essential is of acceptable quality according to FDA criteria

研究概览

简要总结

Collect clinical images requested by FDA with GE Breast Tomosynthesis to show they are of acceptable quality as defined in the relevant FDA guidance document before and after artifact correction and in standard screening images. Lossy compression will also be evaluated to demonstrate that images are of acceptable quality when lossy compression is enabled.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
40 Years 至 —(Adult, Older Adult)
性别
Female
接受健康志愿者

入选标准

  • Ability to provide written informed consent or have a legally authorized representative provide written informed consent
  • Female subjects who are 40 years of age or older
  • Subject has no history of symptoms and/or physical signs of breast cancer on the side of the targeted breast
  • Subject underwent routine Full-Field Digital Mammography (FFDM) which showed one or more abnormalities, including calcifications, and was referred for diagnostic work-up within 4 weeks
  • Subject is surgically sterile (must have documentation of bilateral oophorectomy and/or documented hysterectomy), post-menopausal (must have documentation of cessation of menses for greater than one year) or, if of childbearing potential, a documented negative urine pregnancy test within 4 weeks is required.
  • Subject breast size is compatible with the dimensions of 24x31 cm of the image detector
  • Subject must be in sufficient good health to be able to undergo an examination on mammography equipment as determined by the Investigator

排除标准

  • Subject or a legally authorized representative is unable to provide written informed consent
  • Clinical assessment and DBT cannot be performed within 4 weeks of screening FFDM examination
  • Subject is breast-feeding
  • Subject has breast implants or reconstructed breasts
  • Subject is undergoing radiotherapy or chemotherapy
  • Subject has a history of prior radiotherapy treatment on the side of the targeted breast
  • Subject has been previously enrolled in this study
  • Subject is participating or has participated in another trial of an investigational product

结局指标

主要结局

DBT in Senographe Essential is of acceptable quality according to FDA criteria

时间窗: Phase 1_12 clinical cases read. Maximum time frame for read to result: 2 weeks

Collect 12 clinical DBT cases with MLO and CC views taken from the Senographe Essential to assess whether the DBT in Senographe Essential is of acceptable quality according to FDA criteria following the clinical evaluation instructions described in Section 9 of the guidance document "Guidance for Industry and FDA Staff: Class II Special Controls Guidance Document: Full-Field Digital Mammography System". Assessment will include review of images with and without artifact correction and with and without lossy compression and findings will be included in PMA submission.

次要结局

未报告次要终点