A Retrospective Post-Market Clinical Study of the Flow Re-Direction Endoluminal Device System in the Treatment of Intracranial Aneurysms
试验速览
- 阶段
- 不适用
- 状态
- 尚未招募
- 发起方
- 入组人数
- 2,000
- 主要终点
- O'Kelly-Marotta, OKM grade (Imaging Evaluation of a Target Aneurysm)
研究概览
简要总结
To evaluate the long-term safety and efficacy of Flow Re-Direction Endoluminal Device System (FRED) in the treatment of intracranial aneurysms in the post-market environment
详细描述
Study Objective: To evaluate the long-term safety and efficacy of Flow Re-Direction Endoluminal Device System (FRED) in the treatment of intracranial aneurysms in the post-market.
Study Design: Post-market, retrospective, multi-center, observational clinical study Study Population: Patient who has implanted at least one observational device in China mainland.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Retrospective
入排标准
- 年龄范围
- 18 Years 至 90 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •People in China mainland who have been treated with FRED. The patients for whom clinical data are available
排除标准
- •Patients who met the inclusion criteria at all time points were required to be included in the study. Therefore, no specific exclusion criteria were set.
结局指标
主要结局
O'Kelly-Marotta, OKM grade (Imaging Evaluation of a Target Aneurysm)
时间窗: 6 month, 1 year
Based on the evaluation of imaging results, the treatment of aneurysms was classified according to the following criteria. Digital Subtraction Angiography (DSA), Magnetic Resonance Angiography (MRA), or Computed Tomography Angiography (CTA) are acceptable, and it is recommended base CTA. The purpose of imaging follow-up information collection is to observe the effect of on the long-term closure of the aneurysm after treatment. Complete closure of the aneurysm would be associated with increased safety.
Re-sheathing performance
时间窗: Immediate post-procedure
During procedure, the observational device can be retrieved / re-sheathed into the microcatheter and re-deployed at the desired target location or removed completely from the patient. But it must not be re-deployed more than three times. Re-sheath performance refers to the retrieving and re-deploying of observational device recorded during the procedure. Information such as the number of recoveries and the number of re-sheathings, the success rate of re-opening and other information are recorded to evaluate the re-sheath performance of the observational device.
Raymond-Roy Grade (Adequate Occlusion Rate of Target Aneurysm)
时间窗: 6 month, 1 year
Adequate Occlusion is defined as Raymond-Roy Grade I or Grade II on imaging evaluation of the target aneurysm.
Technical Success rate
时间窗: Immediate post-procedure
The technical success rate refers to the proportion of technically successful patients in the total number of patients. Technical success is defined as successful stent placement and meet following criteria: Stent fully cover the aneurysm neck; Good wall apposition; Perfusion of the parent artery; Retention of contrast agent within the aneurysm;
Modified Rankin Scale (mRS)
时间窗: 6 month, 1year
The modified Rankin (mRS) score was used to evaluate the improvement of neurological function. The modified Rankin score assesses the ability to live independently in patients with Neurological disease \[6\]. There are 7 levels of this score, 0 points represent no symptoms of disability, higher scores mean worse prognosis of patients, and 6 points represent death, See the table below for detailed scores.