跳至主要内容
临床试验/NCT07403851
NCT07403851已完成不适用

Effect of Scanning Technology on the Accuracy of Digitally Customized Intraradicular Attachments: A Cross Overstudy

October 6 University1 个研究点 分布在 1 个国家目标入组 21 人开始时间: 2026年5月1日最近更新:
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
21
试验地点
1
主要终点
Accuracy

研究概览

简要总结

This study aims to evaluate the accuracy of intra-radicular attachments fabricated by direct scanning using three different scanners in vivo. The primary outcome will be the accuracy of the fabricated attachments, while secondary outcomes will includepatient-reported comfort during procedure of taking intraradicular attachment conventional impression and direct scanning.

详细描述

The fabrication of intra-radicular attachments is a critical step in restoring endodontically treated teeth. The accuracy of these restorations directly impacts their clinical performance, including retention, marginal fit, and long-term success. With advancements in digital dentistry, intraoral scanners (IOS) have become increasingly popular for direct scanning of intra-radicular preparations. However, the accuracy of these scanners varies depending on their technology, software, and clinical conditions

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Other
盲法
Single (Outcomes Assessor)

入排标准

年龄范围
18 Years 至 65 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients aged 18-65 years.
  • Endodontically treated teeth requiring intra-radicular attachments.
  • Adequate oral hygiene .
  • Periodontally Compromised Teeth: When some teeth have reduced bone support but can still be maintained as overdenture abutments with proper treatment.

排除标准

  • Severely Compromised Remaining Teeth: If the remaining teeth have poor prognosis due to extensive decay or severe periodontal disease.
  • Severe Bone Loss Around Abutment Teeth: If the remaining teeth do not provide adequate support, they may fail early, leading to additional complications.
  • Severe Malocclusion: Where occlusal discrepancies make overdenture placement difficult.
  • Limited inter-arch Space: cann't accommodate the overdenture components. 5 . Poor Oral Hygiene: increase the risk of decay or periodontal issues in retained abutments.

研究组 & 干预措施

Group III

Experimental

Intraoral scanning by Intraoral scanner B

干预措施: Planmeca Emerald S intraoral scanner (Device)

Group I

Active Comparator

Indirect scanning by desktop scanner (for the conventional impression)

干预措施: 3 shape desktop scanner (Device)

Group II

Experimental

Intraoral scanning by Intraoral scanner A

干预措施: SHINING 3D intraoral scanner (Device)

结局指标

主要结局

Accuracy

时间窗: Immediately after scanning.

measure accuracy between the dimension of the prepared canal gained by intra-radicular impression and the dimension of the prepared canal directly by two different types of intraoral scanners

次要结局

  • Patient-reported comfort(Immediately after impression taking and scanning.)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Afnan Gamal Mohamed Qamar

Teaching assistant in removable prosthodontic department

October 6 University

研究点 (1)

Loading locations...

相似试验