跳至主要内容
临床试验/NCT07433543
NCT07433543已完成不适用

Acute Blood Pressure and Range of Motion Responses to Cervical Foam Rolling: a Randomized Controlled Crossover Trial

University of Palermo1 个研究点 分布在 1 个国家目标入组 24 人开始时间: 2025年5月26日最近更新:
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
24
试验地点
1
主要终点
Systolic pressure, diastolic pressure, and mean arterial pressure

研究概览

简要总结

Foam rolling (FR) is a technique involving the application of external pressure to muscles and connective tissues using different devices (e.g. foam rollers, massage rollers, balls, etc.) , with the aim of reducing muscle tension, soreness, and stiffness, and improving circulation, and flexibility. Emerging evidence suggests that FR may also enhance tissue perfusion and blood flow and could induce a relaxation response, potentially modulating autonomic balance toward increased parasympathetic activity. The cervical region is of particular interest due to the presence of clinically relevant vascular structures, such as the carotid arteries, whose mechanical stimulation may elicit cardiovascular responses. Accordingly, the present study was designed to investigate the acute effects of cervical foam rolling on blood pressure, while simultaneously examining tissue hardness and heart rate variability as potential underlying mediators, and to explore a possible dose-response relationship between foam rolling volume and blood pressure through an inter-set analysis. Additionally, the acute effects of cervical foam rolling on local range of movement were also investigated.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Basic Science
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • healthy participants aged 18 years or older

排除标准

  • use of antihypertensive medication;
  • orthopedic, neurological, renal, metabolic, or cardiovascular disorders.

研究组 & 干预措施

Cervical foam rolling

Experimental

Four sets of 45 foam rolls were self-administered on the right posterolateral cervical region, with 45 seconds of recovery between sets.

干预措施: Cervical foam rolling (Other)

Control

No Intervention

Participants in the control condition remained seated for 6 minutes, matching the duration of the FR intervention protocol.

结局指标

主要结局

Systolic pressure, diastolic pressure, and mean arterial pressure

时间窗: - Day 1: Baseline (upon arrival) and immediately post-intervention; - Day 2: Baseline (upon arrival) and immediately post-intervention.

Systolic and diastolic BP were measured by using a validated oscillometric device. During the blood pressure assessment, participants were instructed to remain seated and relaxed. The mean arterial pressure (MAP) was subsequently extrapolated using the following formula: MAP=DP+1/3(SP-DP).

Tissue Hardness

时间窗: - Day 1: Baseline (upon arrival) and immediately post-intervention; - Day 2: Baseline (upon arrival) and immediately post-intervention.

Tissue hardness was collected using a portable tissue hardness meter. In the cervical region, the spinous process of C7 was used as the reference point. Measurements were obtained bilaterally to the C7.

Heart rate variability

时间窗: - Day 1: Baseline (upon arrival) and immediately post-intervention; - Day 2: Baseline (upon arrival) and immediately post-intervention.

Heart rate variabity was collected using a Polar H10 sensor chest strap device, a device validated for assessment of RR intervals.

Cervical range of motion (ROM)

时间窗: - Day 1: Baseline (upon arrival) and immediately post-intervention; - Day 2: Baseline (upon arrival) and immediately post-intervention.

Cervical ROM was measured using an inertial measurement unit (GYKO; Microgate, Bolzano, Italy). The accelerometer was secured to the participant's forehead and measured active cervical flexion, extension, right and left rotation, and right and left inclination.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Ewan Thomas

Ewan Thomas - Associate Professor, Department of Psychology, Educational Science, and Human Movement

University of Palermo

研究点 (1)

Loading locations...

相似试验