NCT01518686已完成不适用
Normal Values for the Full Visual Field, Corrected for Age- and Reaction Time, Using Semi-automated Kinetic Testing on the Octopus 900 Perimeter
适应症
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 86
- 试验地点
- 2
- 主要终点
- Measurement of the full Visual Field using semi-automated kinetic perimetry.
研究概览
简要总结
The purpose of this study is to determine normal values of the visual field (VF), corrected for age- and reaction time (RT) using the Octopus 900 perimeter and semi-automated kinetic perimetry (SKP).
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Diagnostic
- 盲法
- None
入排标准
- 年龄范围
- 11 Years 至 79 Years(Child, Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •maximum spherical ametropia ± 6 Diopters (D)
- •maximum cylindrical ametropia ± 2 D
- •distant visual acuity ≥ 1.0 logMAR [20/20] for subjects up to 60 years, ≥ 0.8 logMAR [20/25] for subjects from 61-70 years, ≥ 0.63 logMAR [20/30] for subjects older than 70 years
- •isocoria, pupil diameter > 3mm
- •intraocular pressure (air pulse tonometer) ≤ 21mmHg
- •normal anterior segments
- •ocular fundus: normal appearance of the cup to disc ratio (CDR) ≤ 0.5, interocular difference of CDR < 0.3
- •normal macular region, vessels, and peripheral retinal examination (with undilated pupils).
排除标准
- •amblyopia
- •strabismus
- •ocular motility disorder
- •diseases of the retina
- •glaucoma, glaucoma suspect
- •macular degeneration
- •IOP > 21 mmHg
- •abnormal color vision test (ISPP - Ishihara and Standard Pseudoisochromatic Plates = SPP)
- •history or findings of other neuro-ophthalmological disease
- •relevant opacities of the central refractive media (cornea, lens, vitreous body)
- •use of miotic drugs
- •intraocular surgery (except uncomplicated cataract surgery, more than three months previous to testing)
- •kerato-refractive surgery (LASIK)
- •drugs influencing reaction time
- •drugs indicating severe general diseases (anti-diabetic pharmaceuticals and anti-hypertensive medication were allowed for subjects older than 70 years)
- •mental diseases (for example psychosis)
- •pregnancy, nursing
- •acute infections
- •heavy smoking (>10 cigarettes /day)
- •alcohol abuse
- •diabetic retinopathy
- •coronary heart disease
- •Raynaud's syndrome
- •suspected lack of compliance
结局指标
主要结局
Measurement of the full Visual Field using semi-automated kinetic perimetry.
时间窗: one day
additional a subgroup of 14 participants were tested at 3 separate sessions within 4 weeks.
次要结局
未报告次要终点
研究者
Ulrich Schiefer
Prof. Dr. med Ulrich Schiefer
University Hospital Tuebingen
研究点 (2)
Loading locations...
相似试验
已完成
不适用
Vision Measured by the Vimetrics CVA Compared With Chart Testing Under Similar Luminance and Contrast ConditionsMaculopathyCataractRefractive ErrorNCT02028351Sinclair Technologies, LLC150
Unknown
不适用
Comprehensive Evaluation of Visual FunctionVisual FunctionNCT00894192The Chicago Lighthouse300
已完成
不适用
Feasibility of Visual Field Screening AppsVisual Field Defect, PeripheralNCT05169983University Hospital Southampton NHS Foundation Trust45
已完成
不适用
Development of Visual Function Evaluation MethodRetinitis PigmentosaNCT03281005Astellas Pharma Inc18
已完成
不适用
Development of Visual Function Evaluation Method (2)Retinitis PigmentosaNCT03626207Astellas Pharma Inc8