跳至主要内容
临床试验/NCT06377163
NCT06377163已完成不适用

Bacterial Pathogens Associated With Community-acquired Pneumonia in Children

Delta University for Science and Technology1 个研究点 分布在 1 个国家目标入组 100 人开始时间: 2021年1月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
100
试验地点
1
主要终点
Gastric lavage culture or sputum culture on admission

研究概览

简要总结

Pediatric community acquired pneumonia (CAP) is one of the most common reasons for hospital admission, there is no reliable way of distinguishing the causative organism based on clinical features.

This study examined common pathogens of community-acquired pneumonia from 28 days up to 10 years in Dakahlia Governorate.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Retrospective

入排标准

年龄范围
28 Days 至 10 Years(Child)
性别
All
接受健康志愿者

入选标准

  • 未提供

排除标准

  • 未提供

结局指标

主要结局

Gastric lavage culture or sputum culture on admission

时间窗: At the baseline evaluation

It was inserted through the nose and down the stomach after nebulization with hypertonic saline at 5% for 10 seconds. Suction was applied for up to 15 seconds to collect the swallowed sputum in a sterile container. A culture was considered positive if any organism was identified.

Complete blood count

时间窗: At the baseline evaluation

From each participant, a sample of 4 ml of fresh venous blood was collected from the peripheral vein by the sterile venipuncture technique \& drawn into a vacuumed purple top tube containing an anticoagulant. It was performed using a fully automated hematology analyzer. This test measures the amounts and sizes of red blood cells, hemoglobin, white blood cells, and platelets. It will be aggregated to arrive at one report. Hemoglobin is usually reported in units of grams per liter, or grams per deciliter. The analyzer counts red blood cells, reporting the result in units of 106 cells per microliter of blood or 1012 cells per liter, and measures their average size, which is called the mean cell volume and expressed in femtoliters or cubic micrometers. The total white blood cell count is usually reported in cells per microliter of blood, or 109 cells per liter. The platelet count can be reported in units of cells per microliter of blood, 103 cells per microliter, or 109 cells per liter.

C-reactive protein (CRP)

时间窗: At the baseline evaluation

It was measured quantitatively in human serum by Beckman-Coulter AU Analyzers (USA). Sample preparation: 2 ml of blood in a sterile tube was centrifuged, then used immediately for CRP. C-reactive protein (CRP) is an annular (ring-shaped) pentameric protein found in blood plasma whose circulating concentrations rise in response to inflammation. Traditional CRP measurement only detected CRP in the range of 10 to 1,000 mg/L, whereas high-sensitivity CRP (hs-CRP) detects CRP in the range of 0.5 to 10 mg/L.

Blood culture and sensitivity on admission

时间窗: At the baseline evaluation

It was done using the BD Bactec 9050 Blood Culture System (USA, Catalog No. 445800) instrument. A culture was considered positive if any organism was identified.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Amira Hussin Hussin Mohammed

Assistant professor at faculty of physical therapy

Delta University for Science and Technology

研究点 (1)

Loading locations...

相似试验

Bacterial Pathogens Associated With... | 临床试验