A Single Center Experience:Safety and Efficacy of DEB-TACE Performed With a Novel Reflux-control Microcatheter in Patients With Early and Intermediate HCC.
试验速览
- 阶段
- 不适用
- 发起方
- 入组人数
- 30
- 试验地点
- 1
- 主要终点
- Disease Control Rate (DCR)
研究概览
简要总结
BACKGROUND:
Hepatocellular carcinoma is the fifth most frequent cancer in the world, with a diagnosis of more than 500,000 new cases per year. It is considered the third leading cause of cancer mortality and presents well-defined risk factors. Liver cirrhosis is the main risk factor for developing HCC, therefore screening programs in cirrhotic patients will allow the early diagnosis of this neoplasia. Despite this, most HCCs are diagnosed at a stage in which the application of curative therapies is no longer possible.
Hepatic transarterial chemoembolization (TACE) belongs to the arterially directed embolization therapies for the treatment of unresectable early-to-advanced hepatocellular carcinoma (HCC). It is the only therapy that has shown to improve survival in intermediate-stage HCC.
Drug-eluting beads (DEB)-TACE has shown to provide slow drug elution, reduced liver and systemic toxicity, increased local drug concentration, and tissue necrosis.
Aside from TACE, other transarterial options include bland embolization, or hepatic artery embolization (HAE), and transarterial radioembolization (TARE). All have an acceptable safety profile, and each has its associated procedural and peri-procedural complications. One potential complication that may occur during all embolization procedures is when the embolic material migrates outside of the desired treatment area, leading to non-target embolization (NTE). In fact, when collateral vessels are embolized, there is a risk that these may be feeders of non-target tissue or organs.
NTE following TACE in particular may lead to a double-layer problem: dangerous components affecting healthy tissue, one ischemic and one related to cytotoxicity from the chemotherapeutic agent, which may have clinical consequences, and potential incomplete treatment of the lesion (due to beads being "deviated" from target).
NTE is highly recognized, but often thought to be uncommon, and although different complications can be caused by it, there may appear to be no evidence of NTE during the intraprocedural imaging.
To avoid the complications due to NTE, apart from the importance of the pre-, intra- and post-procedural imaging, and the thorough study of the anatomical picture, the catheters/microcatheters should also be chosen with reason and care. In particular, selective catheterization should be achieved by placing the microcatheter tip as close as possible to the target, through the specific branch/branches supplying it.
However, even with the microcatheter selectively positioned in the vessel to be embolized, the risk of NTE might not be eliminated, since it could happen as a result of changes in flow dynamics that occur during embolization, particularly when the endpoint is stasis. These changes could result in reflux into non-target territories and, as such, might be better prevented with the use of microcatheters intended to reduce reflux. To this purpose, the use of a dedicated delivery device should be taken into consideration, in order to optimize and save time during the procedure.
Microcatheters are commonly used during most arterial embolization procedures, and as explained above, there is a strong rationale to use a reflux-control microcatheter - like Sequre - for DEB-TACE.
The main expectation is to achieve technical success with Sequre in all patients with a reachable target lesion, with the intent not only to minimize potential damage to surrounding tissue, but also to potentially deliver more treatment embolics, as all the beads are (re)directed towards the target.
The use of small diameter particles (100 micron-TANDEM ® spheres), induces superior tumor necrosis response (Urbano et al., European Journal of Radiology, 2020); with the synergistic effect of being administered through the SEQURE anti-reflux protection system, there is reason to believe that it will be possible to administer maximum doses of doxorubicin, while avoiding the occlusion of non-target arterial segments (SYNERGIC EFFECT).
STUDY PROPOSAL:
We propose a prospective observational study with data collection from a single center (Virgen de las Nieves University Hospital-Granada), for a period that ranges October 2020-December 2021. Here summarized the inclusion criteria and contraindications:
Inclusion criteria
- BCLC B and or some case BCLC A
- Both genders
- Over 18 years.
- Bilirubin less than 3 gr/dl.
- No contraindications to the use of iodinated contrast
- Absence of chronic kidney disease
- ECOG 0-1.
- Absence of encephalopathy.
- Informed consent.
Contraindications
- Advanced liver disease.
- Thrombosis or reversal of portal flow.
- Vascular invasion.
- Extrahepatic spread.
- Contraindication to administration of cytostatics.
- Contraindication to angiographic procedure.
详细描述
Microcatheters are commonly used during most arterial embolization procedures. SEQURE® (Guerbet, France) is an innovative reflux-control microcatheter for peripheral embolization procedures which relies on flow dynamics as the foundation of its' mechanism of action. It can optimize the delivery of calibrated microspheres of specific sizes.
The device presents as a regular microcatheter with a non-tapered internal lumen for delivery of embolics (typically in suspension with contrast media), and 2 radiopaque markers (placed at a distance of 11 mm) at the tip (distal marker being at 0.5-1 mm from the point of exit).
Near the distal atraumatic tip, between the two markers, it has side slits (approximately 50 µm in width) which allow contrast media to exit radially in addition to the standard fluid flow through the distal tip of the catheter. The contrast media that comes out of the side-holes creates a turbulence in the space surrounding the slits, between microcatheter and vessel, which acts as a fluid barrier in that given portion. This fluid-dynamic barrier redirects the beads that tend to upstream reflux back to their flow-directed trajectory, preventing the beads from migrating in non-target areas, and thus eliminating, or strongly reducing, undesired non-target embolization (NTE).
Moreover, SEQURE® allows for haemodynamic arrangement to be preserved, by favoring and maintaining unaltered the natural blood flow. Under fluoroscopy, the radial flow of contrast media exiting through the side holes in the SEQURE® microcatheter can be seen, giving the physician indication of the vessel flow dynamics.
Lesions were identified and then treated supra-selectively with the microcatheter, with the embolic materials infused in a slow and controlled manner, in order to reduce reflux into non-target branches
研究设计
- 研究类型
- Observational
- 观察模型
- Case Only
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •BCLC B and or some case BCLC A
- •Both genders
- •Over 18 years.
- •Bilirubin less than 3 gr/dl.
- •No contraindications to the use of iodinated contrast
- •Absence of chronic kidney disease
- •Absence of encephalopathy.
- •Informed consent.
排除标准
- •Advanced liver disease.
- •Thrombosis or reversal of portal flow.
- •Vascular invasion.
- •Extrahepatic spread.
- •Contraindication to administration of cytostatics.
- •Contraindication to angiographic procedure.
结局指标
主要结局
Disease Control Rate (DCR)
时间窗: Assessed at 6 months after patient inclusion
DCR is defined as a complete, partial response or stable disease among total of treated cases, according to mRECIST evaluated by CT or MRI. The value of these data is a percentage considering tumour diameter before and after treatment.
Adverse Events (AEs) and Serious Adverse Events (SAE)
时间窗: Assessed up to 30 days after patient inclusion
The incidence of emerging AE and SAE will be summarized according to standardized qualification criteria (JVIR SAE), including pancreatitis, cholecystitis, clinical presentations, PES, etc.
Objective Response Rate (ORR)
时间窗: Assessed at 6 months after patient inclusion
ORR is defined as a complete or partial response among total of treated cases, according to mRECIST evaluated by CT or MRI. The value of these data is a percentage considering tumour diameter before and after treatment.
Technical success
时间窗: up to 1 hour after patient inclusion (or after patient treatment)
Defined as a composite outcome measurement: ability to place the micro-catheter inside the required vascular segment and qualitative assessment of microspheres deposition in the target tumour.
次要结局
未报告次要终点
研究者
Juan José Ciampi Dopazo
Principal Investigator and Clinical Professor
University Hospital Virgen de las Nieves