Multi-day (3) In-patient Evaluation of Intradermal vs Subcutaneous Basal/Bolus Insulin Infusion

Becton, Dickinson and Company2 个研究点 分布在 1 个国家目标入组 23 人开始时间: 2012年2月最近更新:
适应症

试验速览

阶段
1 期
状态
已完成
入组人数
23
试验地点
2
主要终点
Insulin levels

研究概览

简要总结

The primary objective of this study is to investigate if intradermal (in the skin) basal and bolus insulin delivery of a fast acting insulin analog (NovoRapid) as needed to adequately control the blood glucose for a subject with Type 1 Diabetes can be maintained for a period of up to three days and if intradermal delivery of insulin has advantages over standard subcutaneous (under the skin) delivery.

详细描述

The is a single center, open-label, 2 period crossover study randomized by route (intradermal versus subcutaneous) in patients with Type 1 diabetes. Subjects will receive their insulin, basal and bolus dosages, via intradermal (ID) and subcutaneous (SC) infusion sets over a three day period.

Each subject will participate in 3 visits: a Screening Visit (V1), followed by 2 experimental intervention days (V2 and V3) to be started 2 - 21 days after screening visit. The minimum/maximum interval between study days shall be 5 to 28 days. Each subject will remain in the clinic for approximately 3 days during the experimental interventions. A final exam will be performed at the end of Visit 3.

After successful screening and enrollment subjects are admitted to the clinic. Their insulin pump and infusion set is replaced by the investigational system, a commercially available insulin pump and either the intradermal infusion set (Research Catheter Set, BD) or the subcutaneous infusion set (Quick Set, Medtronic)to include an in-line pressure transducer/recorder and insulin NovoRapid. The initial pump infusion rate is established based on the patient's known basal infusion rate and the meal bolus insulin is estimated based on the patient's known insulin sensitivity. An intravenous (in the vein) catheter line is established, blood glucose is measured at least every 2 hours overnight and insulin corrections can be implemented, if deemed necessary. The overnight and pre-prandial (before meal) target range is 70-160 mg/dl, although the procedure will continue as planned if the patient is outside the range. It should be the goal not to give any IV glucose or insulin at all, and not to change basal insulin settings for at least 2 hours before the meal. The breakfast meal will be a high GI (60g carbohydrates) solid meal, to be consumed within 15 minutes and followed for a period of 6 hours of blood sampling for glucose and insulin levels. Lunch will be served as standardized mixed meal, and followed for a period of 4-6 hours. This procedure is repeated on days 2 and 3 whereas the breakfast and lunch meal as well as the insulin dose to cover the meal are the same. A light evening dinner is served every day, composition and insulin dose to be recorded. On day three after the 4 hour period following lunch the catheter will be removed, catheter and site assessments will be documented and an ultrasound observation of the infusion site (skin thickness and SC) versus an adjacent control site will be performed within 10 min after removal of the infusion set. Glucose rescue, if necessary, will be administered orally (juice, 200 mL). Insulin correction boli should be delivered via the investigational infusion set.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 55 Years(Adult)
性别
All
接受健康志愿者

入选标准

  • 未提供

排除标准

  • 未提供

结局指标

主要结局

Insulin levels

时间窗: 0,10,15,20,25,30,35,40,45,50,55,60,65,70,80,90,120,150,180,210,240,300,330,345,360 minutes following each breakfast and lunch meal bolus for the 3 study days

Time to peak plasma concentration (Tmax) of insulin delivered intradermally as compared to insulin delivered subcutaneously after a meal bolus.

次要结局

  • Insulin levels(0,10,15,20,25,30,35,40,45,50,55,60,65,70,80,90,120,150,180,210,240,300,330,345,360 minutes following each breakfast and lunch meal bolus for the 3 study days)
  • Blood Glucose(0,10,15,20,25,30,35,40,45,50,55,60,65,70,80,90,120,150,180,210,240,300,330,345,360 minutes following each breakfast and lunch meal bolus for the 3 study days)
  • Device performance - adhesion(Evaluated at every timepoint a bolus injection is given)
  • Skin thickness using ultrasound(Upon removal of the device (within 5 minutes))
  • Device performance - Leakage of fluid (insulin) at injection site(Immediatley before and after each bolus injection and immediatly upon removal of the device at the end of the study period.)
  • Device performance-pump alarm(over the 3 study days)
  • Skin effects-Draize Scoring for Skin Irritation(Following removal of the device (within 2 minutes) and 1 and 2 hours (+/- 5 minutes) post removal.)
  • Number of participants with adverse events(up to 53 days or until the subject is discharged, if sooner.)