Baha Bone Conduction Implants and Magnetic Resonance Imaging
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 20
- 试验地点
- 1
- 主要终点
- Artifact size, measured in millimeters, on MRI sequences.
研究概览
简要总结
Bone conduction implants (BCI) are widely used in cases of conductive/ mixed hearing loss or single side deafness when surgical treatment or air hearing aids are not feasible. There are two types of BCI, abutments (which pass through the skin) and magnets (where a subcutaneous magnet is coupled to an external magnet). Pathologies (such as cholesteatoma) leading to the insertion of this hearing implant often require prolonged MRI follow-up. However, both the abutment and the magnet are responsible for imaging artifacts that limit its interpretation. Frequency and extent of these artifacts remain unclear in the literature. In our experience, the magnet, due to its size and composition, produces larger artifacts than the abutment. The main objective of our study is to compare MRI artifacts for each of these device types (abutment and magnet).
详细描述
The patients included in the study will all have a cerebral MRI as part of the cholesteatoma follow-up or for the assessment of cerebral or inner ear pathology.
- ENT evaluation: The position of the implant will be evaluated. The distance from the external ear canal (center of the abutment or center of the magnet) will be measured on the patient using a ribbon meter. The angle between the implant and the orbital plane (in degrees) will be evaluated on a profile photograph.
- Imaging evaluation: MRI examinations will be anonymized and sent to a single core laboratory for reading. One reader, a board-certified neuroradiologist with 5 years of experience in inner ear imaging, blinded to all data, will review all MRI examinations on a dedicated workstation with the Carestream Vue PACS software (Carestream Health, Rochester, NY). The main outcome measures will be the size of artifacts and the interpretability of sequences. The following MRI sequences will be performed on a 1.5T scanner (1.5T Philips®, Ingenia), covering the temporal bones :
ROUTINE SEQUENCES
- 2D Diffusion weighted-imaging (WI)
- High-resolution 3D T2-WI TSE (DRIVE)
- Post-contrast 2D T1-WI TSE (axial and coronal planes)
ADDITIONAL SEQUENCES (approximately 20 minutes of additional acquisition time) :
研究设计
- 研究类型
- Observational
- 观察模型
- Case Only
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- 未提供
排除标准
- 未提供
结局指标
主要结局
Artifact size, measured in millimeters, on MRI sequences.
时间窗: baseline
mm
次要结局
未报告次要终点