跳至主要内容
临床试验/NCT02525614
NCT02525614已完成不适用

Evaluation of Triathlon - A New Total Knee Prosthesis System - RSA Triathlon Standard vs. Short Keel

Region Skane0 个研究点目标入组 59 人开始时间: 2009年5月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
Region Skane
入组人数
59
主要终点
Assessment of fixation and stability of the Triathlon total knee prosthesis by Roentgen Stereophotogrammetric Analysis (RSA)

研究概览

简要总结

The objective is to investigate the Clinical, Radiographic, Roentgen Stereophotogrammetric behaviour and patient outcome when using the Triathlon total knee prosthesis in a prospective randomized clinical trial.

详细描述

The objective is to investigate the Clinical, Radiographic, Roentgen Stereophotogrammetric behaviour and patient outcome when using the Triathlon total knee prosthesis in a prospective randomized clinical trial.

The evaluation is carried out by a prospective randomised RSA-study with Triathlon Standard vs. Short Keel.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Double (Participant, Outcomes Assessor)

入排标准

年龄范围
18 Years 至 85 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients suffering exclusively from OA, Stage II-V [Ahlbäck-Traumascore, 1968 391] will be operated.
  • Patients requiring knee prosthesis, suitable for the use of Duracon and Triathlon knee system
  • Patients who understand the conditions of the study and are willing and able to comply with the post-operative scheduled clinical and radiographical evaluations and the prescribed rehabilitation.
  • Patients who signed the Ethics Committee approved Informed Consent Form prior to surgery.

排除标准

  • Previous major knee surgery
  • Other significant disabling problems from the muscular-skeletal system than in the knees
  • Obese patients where obesity is severe enough to affect subject's ability to perform activities of daily living (body mass index, kg/m2: BMI above 35).
  • Patients with active or suspected infection.
  • Patients with malignancy - active malignancy.
  • Patients with severe osteoporosis, Paget's disease, renal osteodystrophy.
  • Patients immunologically suppressed, or receiving steroids in excess of physiologic dose requirements.
  • The patient has a neuromuscular or neurosensory deficit which would limit the ability to assess the performance of the device or the patient has a neurological deficit which interferes with the patient's ability to limit weight bearing or places an extreme load on the implant during the healing period.
  • Female patients planning a pregnancy during the course of the study.
  • Patients with systemic or metabolic disorders leading to progressive bone deterioration.
  • Patients, who as judged by the surgeon, are mentally incompetent or are unlikely to be compliant with the prescribed post-operative routine and follow-up evaluation schedule.
  • Patients with other severe concurrent joint involvements, which can affect their outcome.
  • Patients with other concurrent illnesses, which are likely to affect their outcome such as sickle cell anaemia, systemic lupus erythematosus or renal disease requiring dialysis.
  • Patients under the protection of law (e.g. guardianship).

结局指标

主要结局

Assessment of fixation and stability of the Triathlon total knee prosthesis by Roentgen Stereophotogrammetric Analysis (RSA)

时间窗: 10 years follow-up

Assessment of fixation and stability of the Triathlon total knee prosthesis by Roentgen Stereophotogrammetric as a predictor of late mechanical loosening.

次要结局

  • Investigation of clinical performance and patient outcome with KSS (Knee Society Score)(pre-operative, 3 months, 1, 2, 5, 7 and 10 years)
  • Investigation of patient outcome with radiographic analysis(3 months, 1, 2, 5, 7 and 10 years)
  • Investigation of clinical performance and patient outcome with KOOS patient questionnaire(pre-operative, 3 months, 1, 2, 5, 7 and 10 years)
  • Investigation of clinical performance and patient outcome with EQ-5D patient questionnaire(pre-operative, 3 months, 1, 2, 5, 7 and 10 years)

研究者

发起方
Region Skane
申办方类型
Other
责任方
Sponsor

相似试验