JPRN-UMIN000040532已完成未知
A study of sleep-wake determination accuracy by actigraphic measurement with automatic algorithms compared to polysomnography - A study of sleep-wake determination accuracy by actigraphic measurement with automatic algorithms compared to polysomnography
试验速览
- 阶段
- 未知
- 状态
- 已完成
- 入组人数
- 22
研究概览
简要总结
The accordance as to the sleep/wake judgment per epoch was 87.4% between the newly developed algorithm and PSG, which was equal to previous reports. There were no systematic and significant differences as to the sleep onset, sleep offset, and total sleep time between either two algorithm and PSG. There was significant difference as to the wake after sleep onset with shorter estimation by actigraphic two algorithms, and the total sleep time with longer estimation by them, comparing to PSG.
研究设计
- 研究类型
- Observational
入排标准
- 年龄范围
- 20years-old 至 75years-old(—)
- 性别
- All
入选标准
- 未提供
排除标准
- •Patients who are examined for abnormal nighttime behaviors Other patients who are judged inappropriate by the researcher or research director
研究者
相似试验
已完成
不适用
Validation of Actigraph Measured Sleep During Acute DiverticulitisAcute DiverticulitisNCT01840878Herlev Hospital13
Unknown
不适用
Verification of Computerized Sleep-wake Analysis in Sleep DisordersSleep-wake AnalysisNCT02412527Chang Gung Memorial Hospital330
尚未招募
Unknown
Evaluation of the Accuracy of a Novel Sleep Monitoring Technology Compared to Polysomnography in the Intensive Care UnitSleepNeurological - Other neurological disordersACTRN12623001193662Royal Melbourne Hospital33
已完成
不适用
Sleep Measurement StudySleepNCT04288557University of Leicester31
已完成
不适用
Comparative Study of the ANNE™ One System to Diagnose Obstructive Sleep ApneaObstructive Sleep Apnea of AdultNCT04643782Northwestern University287