Evaluation of STARgraft-3 for Hemodialysis
试验速览
- 阶段
- 不适用
- 状态
- 进行中(未招募)
- 入组人数
- 21
- 试验地点
- 1
- 主要终点
- Primary Unassisted Patency
研究概览
简要总结
This study is a single site, prospective, single arm evaluation of the safety and effectiveness of the Healionics STARgraft-3 hemodialysis access graft. STARgraft devices have been demonstrated in preclinical and other studies to have improved resistance to the common failure modes of venous anastomosis stenosis and infection.
This study is an extension from prior studies with STARgraft AV (NCT03916731) and STARgraft-2 (NCT04783779) investigational devices. A previous study also included control implants of commercially available standard ePTFE grafts approved for the same use.
The study is enrolling patients with End Stage Renal Disease (ESRD) requiring hemodialysis via a prosthetic vascular graft. The study proposes to evaluate the performance of the investigational STARgraft-3 compared to the ePTFE controls in the prior study and to published results, over a period of 6 months, with extended results to 1 year.
Estimated enrollment is 15 subjects in this study.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Male or female, > 18 years or age.
- •Patient has given informed consent to participate in the trial.
- •Stated willingness to comply with all study procedures and availability for the duration of the study.
- •Able to effectively communicate with study personnel.
- •Candidate for a new arterio-venous graft placed in the upper arm.
- •Life expectancy judged to be at least 2 years.
- •Axillary vein of greater than or equal to 7 mm in diameter.
- •Brachial artery of greater than or equal to 4 mm in diameter.
- •Acceptable cardiac risk level (Cardiac Output ≥ 3.5 L/min, Pulmonary Artery Pressure ≤ 50 mmHg, Ejection Fraction ≥ 40%)
- •Systolic blood pressure equal to or greater than 120 mmHg.
- •Absence of central venous stenosis downstream from implant site confirmed with ultrasound and/or venogram.
排除标准
- •Unable or unlikely to comply with trial protocol and/or follow-up.
- •Clinically morbid obesity.
- •Anatomical limitations.
- •Immunodeficiency syndrome.
- •History of bacterial infection within 8 weeks prior to graft implantation.
- •History of hypercoagulation or bleeding disorders.
- •Elevated platelet count > 1 million per microliter of blood.
- •History of heparin-induced thrombocytopenia syndrome (HIT).
- •Medically confirmed stenosis of the veins downstream of the implant site.
- •Inadequate arterial flow or pressure proximal to the implant site.
- •Currently participating in another investigation drug or device study which may clinically interfere with any endpoints of this trial.
- •Fever greater than 38°C.
- •Prior allergic reaction to silicone.
- •Confirmed or suspected COVID-19 infection within 8 weeks prior to graft implant, or ongoing COVID-19 symptoms.
研究组 & 干预措施
STARgraft-3
Participants will be implanted with 6mm diameter STARgraft-3 grafts as an upper arm Brachial Artery to Axillary Vein shunt for hemodialysis access.
干预措施: Implant of STARgraft-3 shunt in the upper arm and subsequent use for hemodialysis access (Device)
结局指标
主要结局
Primary Unassisted Patency
时间窗: 6 months post implantation
Percentage of subjects without an occurrence of either an access thrombosis or an access procedure performed to maintain patency.
次要结局
- Blood Flow Rates in Grafts(2 weeks and 1, 2, 4, 6, 9, and 12 months post implantation)
- Frequency of Interventions(1, 2, 4, 6, 9 and 12 months post implantation)
- Assisted Primary Patency(1, 2, 4, 6, 9, and 12 months post implantation)
- Primary Unassisted Patency(1, 2, 4, 9 and 12 months post implantation)
- Secondary Patency (Cumulative Patency)(1, 2, 4, 6, 9, and 12 months post implantation)
- Safety Outcomes(1, 2, 4, 6, 9, and 12 months post implantation)