跳至主要内容
临床试验/NCT02599831
NCT02599831已完成不适用

Efficacy of Electrical Pudendal Nerve Stimulation for Patients With Post Prostatectomy Urinary Incontinence

Shanghai Institute of Acupuncture, Moxibustion and Meridian1 个研究点 分布在 1 个国家目标入组 96 人开始时间: 2015年11月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
96
试验地点
1
主要终点
ICIQ-UI-SF

研究概览

简要总结

The purpose of this study is to determine whether electrical pudendal nerve stimulation is more effective than pelvic floor muscle training plus transanal electrical stimulation in treating post prostatectomy Incontinence.

详细描述

Conservative therapy could be considered a choice of treatment for stress urinary incontinence (SUI) as it seems to have no side effect and causes significant and long-term improvement in symptoms. Pelvic floor muscle training (PFMT) and electrical stimulation are two commonly used forms of conservative treatment for SUI. PFMT improves the structural support of the pelvis. However, many patients have difficulty identifying and isolating their pelvic floor muscles (PFM) and are unable to perform the exercise effectively. Furthermore, patients who can identify the PFM often find that the required daily exercise routine is burdensome. Hence, the primary disadvantage of PFMT is lack of long-term patient compliance. Electrical stimulation (ES) is a non-invasive, passive treatment that produces a muscle contraction. Transanal electrical stimulation (TES) has little side-effect, and the patient compliance is 70-85% in published reports. TES results in PFM contraction by indirect nerve stimulation, mainly by polysynaptic reflex responses. The indirect stimulation and reflexive contraction may be the reason why the effect of electrical stimulation is not as good as that of PFMT when performed correctly. By combining the advantages of PFMT and TES and incorporating the technique of deep insertion of long acupuncture needles, we developed electrical pudendal nerve stimulation (EPNS). In EPNS, long acupuncture needles of 0.40 Х 100 or 125 mm were deeply inserted into four sacral points and electrified to stimulate the pudendal nerves (PN) and contract the PFM. CT transverse plane at the coccygeal apex has showed that the position of the lower needle tip is similar to where (adjacent to PN at Alcock's canal) the Bion device is implanted for chronic PN stimulation. Our previous study showed that EPNS had a better therapeutic effect on female SUI as compared with PFMT + TES. Simultaneous records of perineal ultrasonographic PFM contraction, vaginal pressure and pelvic floor surface electromyogram in our previous study have proved that EPNS can exactly excite PN and induce PFM contraction in female SUI patients. However, EPNS has also shown satisfactory effect in male patients with SUI problems. The purpose of this study is to compare the efficacy of EPNS to PFMT + TES in treating male SUI.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Single (Outcomes Assessor)

入排标准

年龄范围
25 Years 至 85 Years(Adult, Older Adult)
性别
Male
接受健康志愿者

入选标准

  • incontinence at 1 month or more after RP
  • ≥2 incontinence episodes a week on baseline 7-day bladder diary
  • no residual cancer after RP on pathological examination

排除标准

  • the presence of preoperative incontinence
  • treatment with anticholinergics
  • urinary tract infection or hematuria
  • postvoid residual volume>100 mL

研究组 & 干预措施

Electrical pudendal nerve stimulation

Experimental

Four sacrococcygeal points were selected. Two 0.40Х100 mm needles were inserted perpendicularly to a depth of 80-90 mm 1 cm bilateral to the sacrococcygeal joint, to produce a sensation referred to the root of the penis (perineum) or the anus. Two needles of 0.40Х100 or 125mm were inserted obliquely toward the ischiorectal fossa to a depth of 90 to 110 mm about 1 cm bilateral to the tip of the coccyx, to produce a sensation referred to the root of the penis (or the perineum).

Each two ipsilaterally needles were connected to one electrode from a G6805-2Multi-Purpose Health Device (Shanghai Medical Instruments High-Techno, Shanghai, China), with a frequency of 2.5 Hz and an intensity (45~55 mA). EPNS was given for 60 min a time, 3 times per week for 8 weeks.

干预措施: Electrical pudendal nerve stimulation (Device)

PFM training with Transanal ES

Active Comparator

Electromyogram BF-assisted PFMT (using a nerve function reconstruction treatment system (AM1000B; Shenzhen Creative Industry Co. Ltd, China) and following TES (using a neuromuscular stimulation therapy system (PHENIX USB4, Electronic Concept Lignon Innovation, France)) at a current intensity of < 60 mA (as high as possible within the patient's tolerance) and frequencies of 15 Hz and 85 Hz (alternate 3-minute periods of stimulation) were performed by a specially trained therapist, 20 minutes each time, respectively (a total of 40 minutes), 3 times a week for a total of 8 weeks. The patients were also required to conduct 30 maximal high-intensity PFM contractions for 2-6 seconds (with 2-6 seconds rest), 3 sessions every day at home for a total of 8 weeks.

干预措施: PFM training (Device)

PFM training with Transanal ES

Active Comparator

Electromyogram BF-assisted PFMT (using a nerve function reconstruction treatment system (AM1000B; Shenzhen Creative Industry Co. Ltd, China) and following TES (using a neuromuscular stimulation therapy system (PHENIX USB4, Electronic Concept Lignon Innovation, France)) at a current intensity of < 60 mA (as high as possible within the patient's tolerance) and frequencies of 15 Hz and 85 Hz (alternate 3-minute periods of stimulation) were performed by a specially trained therapist, 20 minutes each time, respectively (a total of 40 minutes), 3 times a week for a total of 8 weeks. The patients were also required to conduct 30 maximal high-intensity PFM contractions for 2-6 seconds (with 2-6 seconds rest), 3 sessions every day at home for a total of 8 weeks.

干预措施: Transanal ES (Device)

结局指标

主要结局

ICIQ-UI-SF

时间窗: 8 weeks

International Consultation on Incontinence Questionnaire-Urinary Incontinence-Short Form

次要结局

  • diaper numbers(8 weeks)

研究者

发起方
Shanghai Institute of Acupuncture, Moxibustion and Meridian
申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...