跳至主要内容
临床试验/NCT07843719
NCT07843719尚未招募不适用

The Utility of a Novel Endoscopic Suturing System in Closing Gastrointestinal Defect - a Pilot Human Study

Chinese University of Hong Kong0 个研究点目标入组 5 人开始时间: 2026年10月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
尚未招募
入组人数
5
主要终点
Incidence of device-related adverse events

研究概览

简要总结

This study is a single-center, prospective, single-arm, non-blinded first-in-human (FIH) early feasibility study intended to evaluate the short-term safety and technical feasibility of closure of gastric post-ESD defects using a novel through-the-scope full-thickness endoscopic suturing system in initial human use.

The subjects shall be patients scheduled to undergo ESD for gastric epithelial lesions at the study site (Prince of Wales Hospital) in Hong Kong who meet the eligibility criteria for this study and from whom written informed consent has been obtained. For the gastric defects created after completion of ESD, closure will be attempted using the study device, and its safety, technical success, and early postoperative maintenance of closure will be evaluated.

The target sample size of this study shall be 5 cases, and no control group shall be established. No comparison with existing defect closure techniques or verification of superiority will be performed. From the viewpoint of patient protection, comparatively controllable gastric post-ESD defects are selected as the entry model, and the safety signal and basic technical success of this device in its initial human use will be evaluated descriptively.

The device specifications used in this study shall remain fixed throughout the study period. During the registration period of the initial cohort of 5 cases, no major changes shall be made to the device itself, accessory equipment, procedural concept, or primary evaluation methods. If device improvement or procedural modification becomes necessary during the study, it shall be handled separately from this initial cohort after obtaining approval from the ethics committee and other relevant authorities, as necessary.

详细描述

Endoscopic suturing platforms are expected to have future applications in more advanced interventional settings, including closure of full-thickness defects, treatment of perforations and fistulas, management of post-resection defects, and bariatric endoscopy. Full-thickness suturing may offer theoretical advantages for larger or deeper defects that are difficult to manage with conventional clip-based methods. At the same time, currently available devices still have important limitations, including technical complexity, restricted maneuverability, and cumbersome setup. For this reason, development of a simpler through-the-scope suturing platform is clinically meaningful.

The Su2ura® GI System was developed as a novel through-the-scope full-thickness endoscopic suturing platform. In preclinical animal experiments, it showed feasibility through a standard endoscopic working channel, a relatively short learning curve, successful full-thickness tissue capture, and acceptable histologic tissue response. The device has demonstrated significant potential as a robust suturing device that could be applied in a number of clinical settings owing to its simplicity in use. Human use of Su2ura® GI system has not yet been reported.

Although the clinical settings in which this device may ultimately be used included full-thickness defects, perforations, fistulas, and bariatric interventions, these are all relatively high-risk situations with considerable risks when adverse event occurs. When introducing a novel device or procedure into clinical practice, it is important not to begin directly in the highest-risk indication, but instead to first establish proof of principle and initial safety in a controlled and predictable setting. The IDEAL framework recommends staged evaluation of new procedures and devices, beginning with small prospective series and emphasizing prospective registration, sequential reporting, and transparent documentation of technical development. Similarly, the FDA guidance on early feasibility studies describes such studies as small clinical investigations intended to obtain proof of principle and initial clinical safety data when nonclinical testing alone is not sufficient to support further development.

Based on the above rationale, closure of post-ESD gastric defects was selected as the target clinical setting for first-in-human study. Post-ESD gastric defects provide a suitable setting for this purpose because they are created during a planned procedure, the location and extent of the defect can be assessed directly during the intervention, and established rescue options remain available if suturing is incomplete or unsuccessful. Compared with true full-thickness defects or perforation cases, this setting is therefore associated with a lower incremental risk when introducing a novel suturing device into human use. Several methods have been described for closure of gastric post-ESD defects, but each has its own advantages and limitations, and no single method has been established as optimal in all situations. Therefore, post-ESD gastric defects should not be regarded as the final target indication of this device, but rather as a controlled clinical entry model in which its basic operability and short-term safety can be assessed in humans before moving to more complex and higher-risk applications.

Accordingly, the purpose of this study is not to demonstrate superiority over existing closure methods or to establish the value of routine closure after gastric ESD. Rather, this study is designed to evaluate the short-term safety and procedural feasibility of a novel through-the-scope full-thickness suturing system under conditions that provide the greatest degree of patient protection for initial human use.

研究设计

研究类型
干预性
分配方式
不适用
干预模型
单组
主要目的
器械可行性
盲法
开放(无盲法)

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • Age 18 years or older
  • Patients scheduled to undergo gastric ESD for gastric epithelial lesions
  • Patients who have received sufficient explanation of this study and from whom written informed consent has been obtained by their own free will
  • Patients judged by the principal investigator or sub-investigator to be appropriate for participation in this study

排除标准

  • Perforation cases requiring emergency closure
  • Cases with severe coagulation abnormalities, bleeding tendency, or other serious systemic conditions, in whom participation in the study is judged to be inappropriate
  • Cases who are pregnant or may be pregnant
  • Cases in whom obtaining consent for this study is difficult, including minor patients
  • Other cases judged to be inappropriate by the principal investigator or sub-investigator

研究组 & 干预措施

Su2ura® GI System Group

Experimental

For the gastric defect created after completion of ESD, closure will be attempted using the study device. Anchors shall be placed alternately on both ends of the defect and repeated until the wound is completely closed. The interval between anchors should be aimed at the discretion of the endoscopist, and the anchors should ideally be placed within 5-10 mm from the edge of the defect. If the defect is large and dead space is likely to be formed during closure, additional anchors shall also be placed on the ulcer base so as to eliminate the dead space. The closure procedure shall be performed by an operator who has received appropriate prior training in the use of the device.

干预措施: Su2ura® GI system (Device)

结局指标

主要结局

Incidence of device-related adverse events

时间窗: 30 days

The primary endpoint shall be the incidence of device-related adverse events and serious adverse events occurring during the procedure or within 30 days postoperatively.

次要结局

  • Technical success(1 day)
  • Complete closure at the end of the procedure(1 day)
  • Closure procedure time(1 day)
  • Number of anchors / suturing elements used(1 day)
  • Need for rescue treatment(30 days)
  • Maintenance of closure at second-look endoscopy(5 day)
  • Incidence of procedure-related clinical adverse events within 30 days(30 days)

研究者

申办方类型
其他
责任方
主要研究者
主要研究者

Hon Chi Yip

Assistant Professor

Chinese University of Hong Kong

标识符

NCT 编号
NCT07843719
其他研究编号
CRE-2026.495

日期

首次提交
(8天前)
首次发布
(前天)
主要完成日期
(12个月后)
研究完成日期
(明年)
最近核实
(29天前)
最近更新
(前天)

监管与共享

FDA 监管药物
否
FDA 监管器械
否
个体参与者数据共享计划
否
是否有结果