跳至主要内容
临床试验/NCT02989948
NCT02989948招募中不适用

Safety and Effectiveness of Physician-Modified Fenestrated and Branched Aortic Endografting for the Treatment of Thoracoabdominal Aortic Aneurysms (TAAA)

Yale University2 个研究点 分布在 1 个国家目标入组 80 人开始时间: 2020年4月22日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
招募中
发起方
入组人数
80
试验地点
2
主要终点
Major Adverse Events (MAE) at 30 days following surgery

研究概览

简要总结

The primary clinical objective of this study is to evaluate the safety and effectiveness of a physician-modified, fenestrated and branched aortic endoprosthesis for the treatment of thoracoabdominal aortic aneurysms (TAAAs). The goal of the primary analysis is to demonstrate both the safety and effectiveness of using a physician-modified fenestrated Cook Zenith Alpha Thoracic Endovascular Graft as compared to previously published results of open surgical replacement of the aneurysmal aorta.

详细描述

This study is a prospective, two-arm, traditional feasibility study of a physician modified fenestrated Cook Zenith Alpha Thoracic Endovascular Graft base device in adult patients meeting traditional size criteria for open surgical treatment of thoracoabdominal aortic aneurysms (TAAAs). Patients meriting surgical treatment of their aneurysm that also meet inclusion and exclusion criteria will be eligible for enrollment. Patients will be followed for 5 years post procedure. Major adverse events (MAEs) will also be recorded by the Sponsor-Investigator (S-I) and will be monitored by a locally appointed Data Monitoring Committee, Dartmouth-Hitchcock Health and the D-HH Human Research Protection Program IRB/IEC, and the FDA. This record was transferred to Yale in October 2024.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
50 Years 至 95 Years(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •MAIN ARM - Inclusion Criteria:
  • •Must be a man or woman 50 years of age or older by the date of informed consent.
  • •Must have a thoracoabdominal aortic aneurysm of any Crawford classification (extent I-V) that extends no more proximal than the left subclavian artery.
  • •Must have an aneurysm size that meets standard indications for surgical repair (6.0 cm in maximum diameter in the descending thoracic aorta, or 5.5 cm in maximum diameter in the abdominal aorta).
  • •Must be considered, in the judgment of the S-I, to be a high risk candidate for open surgical repair.
  • •Must not be a candidate for repair under the Instructions for Use of a commercially available, FDA-approved endovascular graft.
  • •Must be able to provide informed consent.
  • •Must be able to comply with the five year study assessment schedule of events.
  • •Must have a non-aneurysm-related life expectancy, in the judgment of the S-I, of greater than 2 years.

排除标准

  • •Aneurysm due to acute or chronic dissection, intramural hematoma, penetrating aortic ulceration, pseudoaneurysm, mycotic aneurysm, or traumatic transection.
  • •Ruptured or acutely symptomatic aortic aneurysm.
  • •Known connective tissue disorder.
  • •Imaging demonstrating any of the following:
  • •Lack of 20 mm non-aneurysmal proximal seal zone (zone 3, or zone 2 with a carotid-subclavian bypass or transposition).
  • •Lack of 15 mm non-aneurysmal distal seal zone(s) (aortic, common iliac, or external iliac).
  • •Branch vessel target (renal, superior mesenteric, or celiac) < 5 mm or > 10 mm in average diameter.
  • •Untreated left subclavian artery stenosis or occlusion.
  • •Untreated unilateral or bilateral hypogastric artery occlusion.
  • •Signs that the inferior mesenteric artery is indispensable.
  • •Have branching, duplication, aneurysm, or untreatable stenosis of the celiac, superior mesenteric artery, or renal arteries that would preclude implantation of the investigational devices.
  • •Known sensitivities or allergies to stainless steel, PTFE, polyester, polypropylene, nitinol, or gold.
  • •History of anaphylaxis to contrast, with inability to prophylax appropriately.
  • •Have uncorrectable coagulopathy.
  • •Have unstable angina.
  • •Have a body habitus that would inhibit X-ray visualization of the aorta.
  • •Have a major surgical or interventional procedure unrelated to the treatment of the aneurysm planned ≤30 days of the endovascular repair.
  • •Known to be participating in any other clinical study which may affect performance of this device.
  • •Known, visible, or suspected pregnancy, confirmed with a Urine Pregnancy Test (UPT)
  • •Contraindication to oral antiplatelet therapy.
  • •Prisoners or those on alternative sentencing.
  • •Known systemic infection with potential for endovascular graft infection.
  • •Anticipated need for MRI scanning within 3 months of insertion of investigational product.
  • •Other conditions or comorbidities that, in the opinion of the S-I, would exclude the patient.
  • •EXPANDED ACCESS ARM - Inclusion Criteria
  • •Must be a man or woman 50 years of age or older by the date of informed consent
  • •Must have a thoracic, thoracoabdominal, or abdominal aortic aneurysm that necessitates coverage of one or more visceral vessels (celiac, superior mesenteric, or renals) for establishment of proximal and/or distal seal.
  • •Must have an aneurysm size that meets standard size indications for surgical repair (6.0 cm in maximum diameter in the descending thoracic aorta, or 5.5 cm in maximum diameter in the abdominal aorta); or, in the judgment of the S-I, has aneurysm characteristics that portend a high risk of near-term rupture
  • •Must be considered, in the judgement of the S-I, to be a high risk candidate for open surgical repair
  • •Must not be a candidate for repair under the Instructions for Use of a commercially available, FDA-approved endovascular graft
  • •Patient must be able to provide informed consent
  • •Must be able to comply with the five year study assessment schedule of events
  • •Must have a non-aneurysm-related life expectancy, in the judgement of the S-I, of greater than 2 years
  • •EXPANDED ACCESS ARM - Exclusion Criteria
  • •Known or suspected mycotic aneurysm
  • •Ruptured aneurysm with hemodynamic instability
  • •Known connective tissue disorder
  • •Imaging demonstrating any of the following:
  • •Lack of 20 mm non-aneurysmal proximal seal zone (in either native aorta, elephant trunk graft, or aortic arch endograft)
  • •Lack of 15 mm non-aneurysmal distal seal zone(s) (in either native aortoiliac vessels, prosthetic aortoiliac grafts, or aortoiliac endografts)
  • •Branch vessel target (renal, superior mesenteric, or celiac) > 10 mm in average diameter
  • •Known sensitivities or allergies to stainless steel, PTFE, polyester, polypropylene, nitinol, or gold
  • •History of anaphylaxis to contrast, with inability to prophylax appropriately.
  • •Have uncorrectable coagulopathy
  • •Have a body habitus that would inhibit X-ray visualization of the aorta
  • •Have a major surgical or interventional procedure unrelated to the treatment of the aneurysm planned ≤ 30 days of the endovascular repair
  • •Known to be participating in any other clinical study which may affect performance of this device
  • •Known, visible, or suspected pregnancy, confirmed with a Urine Pregnancy Test (UPT)
  • •Contraindication to oral antiplatelet therapy
  • •Prisoners or those on alternative sentencing
  • 另有 3 项未显示

研究组 & 干预措施

Expanded Selection Criteria Arm - Physician-modified fenestrated endovascular graft.

Experimental

Use of a physician-modified fenestrated Cook Zenith Alpha Thoracic Endovascular Graft for the endovascular treatment of asymptomatic, non-ruptured thoracoabdominal, thoracic, or abdominal aortic aneurysms of any Crawford extent (I-V) meeting traditional size criteria for open surgical repair in an expanded use population.

干预措施: Physician-modified aortic endograft (Device)

Main Arm - Physician-modified fenestrated endovascular graft

Experimental

Use of a physician-modified fenestrated Cook Zenith Alpha Thoracic Endovascular Graft for the endovascular treatment of asymptomatic, non-ruptured thoracoabdominal aortic aneurysms of any Crawford extent (I-V) meeting traditional size criteria for open surgical repair.

干预措施: Physician-modified aortic endograft (Device)

结局指标

主要结局

Major Adverse Events (MAE) at 30 days following surgery

时间窗: 30 Days

Percent of patients who development major adverse events

Treatment success at 12 months following surgery

时间窗: 12 Months

Percent of patients achieving treatment success through 1 year

30 day survival

时间窗: 30 Days

Percent of patients who survive 30 days following surgery

Technical success at 12 months following surgery

时间窗: 12 Months

Technical success is assessed 12 months following surgery and is defined as a composite of: successful delivery, without need for unanticipated corrective intervention related to delivery; successful and accurate deployment at the intended implantation site; and successful withdrawal, without need for unanticipated correct intervention related to withdrawal.

次要结局

  • Treatment success(At 30, 183 days; 2, 3, 4 and 5 years)
  • Conversion to open repair(Day of Surgery)
  • Technical success on the day of surgery(Day of Surgery)
  • Paraplegia(Day of Surgery)
  • Survival rate(At 30, 183 days; 1, 2, 3, 4 and 5 years)
  • Lower extremity ischemia(Day of Surgery)
  • Paraparesis(Day of Surgery)
  • Major Adverse Events (MAEs)(At 30, 183 days; 1, 2, 3, 4 and 5 years)
  • Aneurysm rupture(Day of Surgery)
  • Access site complication (Femoral or Iliac)(Day of Surgery)
  • Lower extremity compartment syndrome(Day of Surgery)
  • Stroke(Day of Surgery)
  • Death during surgery(Day of Surgery)

研究者

发起方
Yale University
申办方类型
Other
责任方
Principal Investigator
主要研究者

David Kuwayama

Associate Professor of Surgery

Yale University

研究点 (2)

Loading locations...

相似试验