Pacertool-Study - Safety and Performance of the Presens-Catheter and the Pacer Software

Pacertool AS1 个研究点 分布在 1 个国家目标入组 50 人开始时间: 2023年12月1日最近更新:
适应症

试验速览

阶段
不适用
状态
尚未招募
发起方
Pacertool AS
入组人数
50
试验地点
1
主要终点
Primary Safety Outcome Measures (PreSens-Catheter and PACER Software):

研究概览

简要总结

The study is a non-randomized, two-part, open label, prospective single-site, single arm, safety and performance study. The study is designed to collect acute and long-term clinical data and user reported outcome data from using the PreSens-Catheter and PACER Software during cardiac catheterization and Cardiac Resynchronization Therapy (CRT) device implantation procedures. Subjects with indication for arterial catheterization and CRT will be included.

详细描述

The study consists of two parts:

  1. Initial safety assessment: at least 5 patients undergoing coronary angiography or left heart catheterization and 5 patients undergoing cardiac resynchronization therapy device implantation to demonstrate acute safety and performance of the PreSens-Catheter and the PACER Software for Td measurements.
  2. Safety and performance assessment: At least 35 patients with an indication for CRT implantation according to standard of care to demonstrate acute safety and performance of using the PreSens-Catheter and the PACER Software to measure Td and detect Synergy and Dyssynergy from multisite stimulation, and its utility to deliver measurements for the discrimination of two clinical cardiac reverse volumetric remodeling phenotypes based on Synergy and Dyssynergy in the targeted population.

Subjects will be followed for the duration of the procedure up to 24 hours for any serious adverse events, and subjects receiving a CRT device will be followed for 30 days follow-up for procedure or device-related events and for up to 6 months for cardiac volumetric remodeling phenotyping.

Clinical outcomes: Clinical outcome will be measured as Safety for the placement of the PreSens-Catheter, safety for the PreSens-Catheter and PACER Software combined for the measurement of Td and detection of Synergy/ Dyssynergy from stimulation, and diagnostic/ predictive performance of the PreSens-Catheter and PACER Software with the measurement of end-systolic volume at 6-months follow-up.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Subject has an indication for coronary angiography or left heart catheterization or cardiac resynchronization therapy.
  • QRS duration between 90-150ms.
  • Subject is ≥ 18 years old.
  • Willingness, ability, and commitment to participate in baseline and follow-up evaluations for the full duration of the clinical study.
  • Willing and able to give informed consent.
  • Subject in sinus rhythm with an indication for implantation of a Cardiac Resynchronization Device (Appendix I)
  • NYHA Class II-IV (Ambulatory IV)
  • QRS duration >120ms.
  • Subject is ≥ 18 years old.
  • Willingness, ability, and commitment to participate in baseline and follow-up evaluations for the full duration of the clinical study.
  • Willing and able to give informed consent.

排除标准

  • Subject has unstable angina/ acute coronary ischemia/ infarction
  • Previous myocardial infraction (<6 months)
  • History of blood clothing or bleeding disease
  • Prior history of documented cerebral infarction, TIA or systemic embolism (excluding a postoperative DVT)
  • Subject has an arterial unstable aneurysm
  • Subject has severe peripheral vascular disease
  • Subject has an artificial aortic or mitral valve replacement
  • Subject has severe aortic valve disease
  • Subject has a clinically significant infection (bacteriemia or sepsis)
  • Subject has contraindications to anticoagulation
  • Patients with a serious allergy to drugs necessary for the procedure such as anticoagulants and protamine
  • Subject has left atrial/ ventricular thrombus
  • Patients with severe vascular obstructions in the desired/ presumed insertion path of the catheter
  • Significant or symptomatic hypotension
  • NYHA class IV (hospitalized), severe circulation instability or shock
  • Ongoing/ persistent atrial arrythmias
  • History of Rheumatic fever
  • Subject has sensitivity to contrast media
  • Contraindications to CT or fluoroscopy
  • Distorted cardiac anatomy due to congenital heart disease
  • Pregnant or possibly pregnant
  • Not eligible for thoracotomy procedures
  • Life expectancy <1 years
  • Any other condition that, in the judgement of the investigator, makes the subject a poor candidate for this procedure, the study or compliance with the protocol (includes addictive disease, extensive travel away from the research center)
  • Clinically significant psychological condition that in the investigator's opinion would prohibit the subject's ability to meet the protocol requirements
  • Current enrollment in any other study protocol where testing or results from that study may interfere with the procedure or outcome measurements of this study

结局指标

主要结局

Primary Safety Outcome Measures (PreSens-Catheter and PACER Software):

时间窗: 4 hours

The primary safety outcome of the PreSens-Catheter and PACER Software is the incidence of false positive readings of Synergy resulting from multisite stimulation from PreSens-Catheter in patients with narrow QRS and false negative readings (Dyssynergy) compared to the resulting reading from pacing with the CRT device.

Primary Safety Outcome (PreSens-Catheter):

时间窗: 24 hours

The primary safety outcome is the incidence of procedure or device-related Serious Adverse Events (SAEs and SADEs) on the day of the procedure

Primary Performance Outcome Measures (PreSens-Catheter and PACER Software):

时间窗: 6 months

Detection of Synergy and Dyssynergy to phenotype patients for the prediction of reverse volumetric remodeling response after 6 months of Cardiac Resynchronization Therapy. Outcome is based on the change in End-Systolic Volume (ESV) from baseline to 6 months follow-up in the respective phenotypes. The study is powered to detect a ΔESV of 30% points difference between the Synergy and Dyssynergy characterized patients after 6 months of Cardiac Resynchronization Therapy.

次要结局

  • Performance Outcome Measures (PreSens-Catheter and PACER Software):(4 hours)
  • Safety Outcome Measures (PreSens-Catheter):(30 days)
  • Performance Outcome Measures (PreSens-Catheter)(4 hours)

研究者

发起方
Pacertool AS
申办方类型
Industry