3D vs. 2D Unilateral Biportal Endoscopic Spine Surgery: A Randomized Blinded Crossover Pilot Simulation Study
试验速览
- 阶段
- 不适用
- 状态
- 尚未招募
- 发起方
- 入组人数
- 6
- 主要终点
- Difference in Task Completion Time (seconds) and Error Rate During Spinal Endoscopic Simulation, Assessed Immediately Post-Task
研究概览
简要总结
This study aims to compare three-dimensional (3D) and two-dimensional (2D) visualization in biportal endoscopic spine surgery using a simulated environment. Surgeons will perform standardized tasks on a spine model while using either 3D or 2D endoscopic systems. The goal is to determine whether 3D technology can improve precision, efficiency, and movement control during surgery. The study uses a randomized, blinded, crossover design to ensure objective results and may help guide future training and technology use in spinal endoscopy.
详细描述
Spinal endoscopy, particularly the unilateral biportal endoscopic (UBE) technique, is an increasingly adopted minimally invasive approach for treating lumbar spine pathologies. While it offers clinical advantages over traditional open surgery-including less tissue disruption, reduced blood loss, and faster recovery-its uptake has been limited, in part due to the technical challenges associated with two-dimensional (2D) endoscopic visualization. The lack of depth perception inherent to 2D imaging can impair spatial orientation, hand-eye coordination, and surgical precision, especially in anatomically complex regions such as the lumbar spine.
Three-dimensional (3D) endoscopic systems are designed to address this limitation by restoring binocular depth cues and providing stereoscopic visualization. Preliminary evidence from other surgical fields-such as laparoscopy and cranial neurosurgery-suggests that 3D visualization improves operative performance, task efficiency, and user confidence. However, the benefits of 3D visualization in spinal endoscopy remain poorly understood, with no rigorous controlled studies to date assessing its impact on performance metrics under standardized conditions.
This randomized, blinded, crossover pilot study is designed to objectively evaluate the effect of 3D versus 2D endoscopic visualization on technical performance during simulated UBE procedures. Participants-including surgeons at various experience levels-will complete standardized surgical tasks on high-fidelity lumbar spine models using both 2D and 3D endoscopic systems. Motion tracking technology will be employed to quantitatively analyze instrument movement, capturing key metrics such as path length, velocity, motion economy, and high-velocity excursions.
The crossover design ensures that each participant serves as their own control, and blinding minimizes observational bias during performance assessment. The simulation setting allows for reproducible conditions free from patient-related variability, ensuring that observed differences can be attributed to visualization modality rather than anatomical or clinical complexity.
Findings from this study will provide foundational data on the potential utility of 3D visualization in spinal endoscopy, with implications for surgical training, operative safety, and the future integration of stereoscopic technologies in spine surgery.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Crossover
- 主要目的
- Device Feasibility
- 盲法
- Single (Outcomes Assessor)
盲法说明
In this single-center crossover simulation study, outcomes assessors responsible for performance evaluation and motion data analysis are blinded to the visualization modality used during each session (3D or 2D). Participants are not blinded due to the inherent perceptual differences between the two visualization systems. Investigators supervising the simulation are aware of the intervention assignments for operational purposes but are not involved in outcome assessment. All video and motion tracking data are anonymized and coded prior to analysis to maintain assessor blinding.
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Enrolled in the neurosurgical residency or fellowship program at the Department of Neurosurgery, Cantonal Hospital of St. Gallen, Switzerland
- •Completion of basic neurosurgical training modules, including introductory endoscopic handling
- •Age ≥ 18 years
- •Willingness and ability to provide informed consent
排除标准
- •Prior substantial experience with three-dimensional (3D) endoscopy (defined as > 5 independent procedures performed with 3D visualization systems)
- •Ocular or neurological conditions impairing stereopsis, fine motor control, or safe endoscope handling
- •Inability or unwillingness to complete the simulation protocol
- •Declined participation
研究组 & 干预措施
Three-Dimensional Endoscopy First, Then Two-Dimensional
Participants first perform standardized spinal endoscopic simulation tasks using a stereoscopic three-dimensional (3D) endoscopic system providing binocular depth perception via dual optical channels and polarized glasses. After completing all tasks under 3D visualization, the same participants subsequently repeat the identical tasks using conventional two-dimensional (2D) visualization on the same high-definition endoscopic platform
干预措施: Three-Dimensional Endoscopic Visualization (Device)
Three-Dimensional Endoscopy First, Then Two-Dimensional
Participants first perform standardized spinal endoscopic simulation tasks using a stereoscopic three-dimensional (3D) endoscopic system providing binocular depth perception via dual optical channels and polarized glasses. After completing all tasks under 3D visualization, the same participants subsequently repeat the identical tasks using conventional two-dimensional (2D) visualization on the same high-definition endoscopic platform
干预措施: Two-Dimensional Endoscopic Visualization (Device)
Two-Dimensional Endoscopy First, Then Three-Dimensional
Participants first perform standardized spinal endoscopic simulation tasks using conventional two-dimensional (2D) visualization, with stereoscopic capability deactivated, displaying a monoscopic high-definition image. After completing all tasks under 2D visualization, the same participants subsequently repeat the identical tasks using stereoscopic three-dimensional (3D) visualization on the same endoscopic platform, viewed with polarized glasses.
干预措施: Three-Dimensional Endoscopic Visualization (Device)
Two-Dimensional Endoscopy First, Then Three-Dimensional
Participants first perform standardized spinal endoscopic simulation tasks using conventional two-dimensional (2D) visualization, with stereoscopic capability deactivated, displaying a monoscopic high-definition image. After completing all tasks under 2D visualization, the same participants subsequently repeat the identical tasks using stereoscopic three-dimensional (3D) visualization on the same endoscopic platform, viewed with polarized glasses.
干预措施: Two-Dimensional Endoscopic Visualization (Device)
结局指标
主要结局
Difference in Task Completion Time (seconds) and Error Rate During Spinal Endoscopic Simulation, Assessed Immediately Post-Task
时间窗: Immediately during each simulation session (within minutes of task performance).
Task performance was assessed during standardized spinal endoscopic simulation tasks under both three-dimensional (3D) and two-dimensional (2D) visualization. Task completion time was measured in seconds with a digital stopwatch from the start to the successful completion of each task. Task accuracy was assessed as the number of predefined errors, including deviations from the optimal trajectory or inadvertent contact with marked "no-go" zones on the simulation model. Both measures were collected immediately during each simulation session. Lower times and fewer errors indicate better performance.
次要结局
未报告次要终点
研究者
Felix Corr
Stefan Motov
Cantonal Hospital of St. Gallen
