临床试验/NCT04429464
NCT04429464撤回不适用

AcQBlate Force Confirmatory Study for Atrial Arrhythmias (AcQBlate Force-PRA)

Acutus Medical1 个研究点 分布在 1 个国家开始时间: 2020年10月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
撤回
试验地点
1
主要终点
Subjects that demonstrate electrical isolation of the intended ablation

研究概览

简要总结

AcQBlate Force Confirmatory Study for Atrial Arrhythmias (AcQBlate Force-PRA)

详细描述

Acutus Medical's AcQBlate Force Ablation Catheter when used in combination with the Qubic Force Sensing Module (AcQBlate Force System), is indicated for cardiac electrophysiological mapping, delivery of diagnostic pacing stimuli, and radiofrequency ablation of sustained or recurrent atrial arrhythmias.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Male or female between the ages of 18 to 80 years at time of consent.
  • •Clinically indicated and scheduled for a de novo or repeat catheter ablation of PAF or PerAF
  • •Willing and able to provide written informed consent to to participate in the study and agree to comply with all follow-up visits and evaluations for the duration of the study.

排除标准

  • •In the opinion of the investigator, any contraindication to the planned atrial ablation, including anticoagulation contraindications or sepsis
  • •Continuous AF > 12-months (long-standing persistent AF)
  • •Atrial arrhythmias secondary to electrolyte imbalance, thyroid disease, or any other reversible or non-cardiac cause.
  • •An implanted pacemaker or Implantable Cardiac Defibrillator (ICD).
  • •Structural heart disease or cardiac history as described below:
  • •Left ventricular ejection fraction (LVEF) < 35% based on transthoracic echocardiogram (TTE) within the previous 180-days.
  • •Left atrial size > 55 mm based on TTE within the previous 180-days.
  • •Evidence of heart failure (NYHA Class III or IV).
  • •Previous cardiac surgery, ventriculotomy, or atriotomy (excluding atriotomy for coronary artery bypass).
  • •Previous cardiac valvular surgical or percutaneous procedure, or prosthetic valve.
  • •Coronary artery bypass graft (CABG) or coronary angioplasty (PTCA) procedure within the last 90-days.
  • •Unstable angina or ongoing myocardial ischemia.
  • •Severe uncontrolled systemic hypertension (systolic pressure > 240 mm Hg, diastolic pressure > 140 mm Hg recorded within the last 30-days.
  • •Moderate or severe tricuspid stenosis or regurgitation.
  • •Moderate or severe mitral stenosis or regurgitation.
  • •Interatrial baffle, closure device, patch, or patent foramen ovale (PFO) occluder.
  • •Presence of a left atrial appendage occlusion device.
  • •Previous PV stenting or evidence of PV stenosis
  • •Body Mass Index (BMI) >40 kg/m2
  • •History of blood clotting or bleeding disease.
  • •Any prior history of documented cerebral infarct or systemic embolism (excluding post- operative deep vein thrombosis (DVT)).
  • •Pregnant or lactating (current or anticipated during study follow up).
  • •Current enrollment in any other study protocol where testing or results from the study may interfere with the procedure or outcome measurements for this study.
  • •Any other condition that, in the judgment of the investigator, makes the patient a poor candidate for this procedure, the study or compliance with the protocol (includes vulnerable patient population, mental illness, addictive disease, terminal illness with a life expectancy of less than two years, extensive travel away from the research center)

研究组 & 干预措施

Non-randomized

Experimental

All subjects will be treated using the Acutus Medical's AcQBlate Force Sensing Ablation Catheter in combination with the Qubic Force Sensing Module (AcQBlate Force Sensing System) to treat their arrhythmia.

干预措施: AcQBlate Force Sensing Ablation Catheter (Device)

结局指标

主要结局

Subjects that demonstrate electrical isolation of the intended ablation

时间窗: At the end of their ablation procedure

The Primary Endpoint for Performance is an analysis of the proportion of subjects that demonstrate electrical isolation (block) of the intended ablation targets.

Proportion of subjects who are free from device/procedure related Major Adverse Events

时间窗: Through 30-days post procedure

The Primary Endpoint for Safety is an analysis of the proportion of subjects who are free from device/procedure related Major Adverse Events (MAEs) that occur following the ablation procedure through 30-days.

次要结局

  • Subjects with freedom from an atrial arrhythmia(30-days post index procedure)
  • Analysis of all identified SAEs, SADEs, and UADEs.(Through 30-days post procedure)

研究者

申办方类型
Industry
责任方
Sponsor