跳至主要内容
临床试验/NCT03194763
NCT03194763已完成不适用

Observational Study for Feasibility and Performance of Sub-millisievert Coronary Computed Tomography Angiography (CCTA) for Coronary Artery Anomalies (CAA) in Paediatric Patients

University Hospital, Montpellier1 个研究点 分布在 1 个国家目标入组 50 人开始时间: 2017年7月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
50
试验地点
1
主要终点
CT diagnostic performance evaluation

研究概览

简要总结

Congenital heart defects are the most frequent manifestation of congenital diseases (8 per 1000 live births). Imaging modalities play an increasing role in their diagnosis, follow-up, and pre/post-surgery check-up. Echocardiography usually provides a first line diagnosis, but Coronary CT Angiography (CCTA) also demonstrated its usefulness whenever accurate modelling of anatomic structures is required.

CCTA is well defined for adult patients. This is not the case for paediatric population, which rises two main difficulties:

  • The use of ionising radiation in young subjects involves a very radio-sensitive population, potentially subject to multiple exams during their follow up.
  • Technical issues related to young patients: No breath-holding, uncontrolled movements during acquisition, very high heart rates (making ECG gating more complex) and very small structures.

These conditions usually result in a deteriorated image quality or in radiation dose increase (retrospective gating). These two outcomes are not acceptable for both, clinician and patient.

In this study, investigators make the hypothesis that despite difficult conditions stated above, ultra-low dose acquisitions may results in diagnostic quality acquisition, thanks to state of art CT technologies combined with acquisition parameters specially designed for that purpose.

Investigators aim to demonstrate feasibility and performances of such exams.

详细描述

Fifty paediatric patients are to be enrolled in this study. All these patients were prescribed a coronary angiography CT as part of their follow up for a known or suspected coronary artery anomaly.

Computed Tomography acquisitions are performed on a Revolution CT (GE Healthcare) using a wide detector aperture (160 mm), last generation of iterative reconstruction algorithm and specific reconstruction software reducing cardiac motion artefacts. A rotation time of 0.28 sec is used, with a slice thickness of 0.625 mm and a 0.625 mm reconstruction interval. The acquisition is ECG-gated (prospective) with kV and mAs depending on BMI, heart rate and heart rate variability of patients.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Prospective

入排标准

年龄范围
— 至 18 Years(Child, Adult)
性别
All
接受健康志愿者

入选标准

  • Patients from 0 to 18 years old
  • Known or suspected coronary artery anomalies
  • CCTA prescribed for regular follow up of the pathology
  • No-objection of parents/legal representative of the patient
  • Covered by social security

排除标准

  • 未提供

结局指标

主要结局

CT diagnostic performance evaluation

时间窗: first day

CT diagnostic performance evaluation using a semi-quantitative likert scale

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验