Metabolic Health, IGF-1, and Cardiovascular Fitness Responses to High-intensity Interval Training and Moderate-intensity Continuous Training in Combination with Superimposed Neuromuscular Electrical Stimulation
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 24
- 试验地点
- 1
- 主要终点
- Body composition via Bioelectrical Impedance Analysis (Tanita 418-MA, Japan)
研究概览
简要总结
The aim of this study is to investigate whether neuromuscular electrostimulation (NMES) training coupled with high-intensity interval training (HIIT) and moderate intensity continuous aerobic training has an effect on the metabolic, cardiovascular and hormonal components compared to respective training protocols without concurrent NMES as a exercise performance enhancement strategy.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Screening
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 30 Years(Adult)
- 性别
- Male
- 接受健康志愿者
- 是
入选标准
- •All participants were healthy with no musculoskeletal injuries and had not participated in lower-body resistance training for six months prior to the study.
排除标准
- •Individuals with musculoskeletal injuries and had participated in lower-body resistance training for six months prior to the study has been excluded from the enrollement for the current study.
研究组 & 干预措施
Assessment of post-test anthropometric, demographic and physiological components
干预措施: IGF-1 (Other)
Completion of MICT, MICT+NMES, HIIT, and HIIT+NMES protocols
干预措施: IGF-1 (Other)
Assessment of baseline anthropometric, demographic and physiological components
干预措施: IGF-1 (Other)
结局指标
主要结局
Body composition via Bioelectrical Impedance Analysis (Tanita 418-MA, Japan)
时间窗: From enrollment to the end of treatment at 8 weeks
Weight (kg) Total body fat (kg) Total muscle mass (kg) The anthropometric parameters were assessed using Bioelectrical impedance analysis (Tanita 418- MA Japan) before all testing sessions.
Height (cm) via a stadiometer (Holtain Ltd., UK).
时间窗: From enrollment to the end of treatment at 8 weeks
Height was measured through a stadiometer in the standing position (Holtain Ltd., Crymych, UK).
Heart rate (bpm) via 12-lead ECG
时间窗: From enrollment to the end of treatment at 8 weeks
Heart rate was monitored and recorded throughout baseline and follow-up screenings and all training sessions using 12-lead ECG.
Blood Lactate Concentration (mmol/L) via Lactate Pro 2 analyzer
时间窗: From enrollment to the end of treatment at 8 weeks
In each GXT testing session (pre-post), blood samples were collected from the earlobe using a Lactate Pro 2 handheld analyzer (LT-1730, Arkray Inc, Kyoto, Japan) to determine blood lactate concentrations testing session (baseline) and at the end of every two minutes interval.
SERUM INSULIN-LIKE GROWTH FACTOR-1 (IGF-1 ng/mL)
时间窗: From enrollment to the end of treatment at 8 weeks
A 5 mL fasting blood sample was drawn from the brachial vein 30 minutes before baseline and follow-up IVO2max tests to measure serum IGF-1 concentrations. Participants rested for 15 minutes before sample collection. Samples were stored at -80 °C and analyzed post-study. Serum IGF-1 levels were measured using Elabscience ELISA kits (detection range: 1.56-100 ng/mL; sensitivity: 0.94 ng/mL) per the manufacturer's instructions.
VO2 - Volume of oxygen (ml/kg/min) VCO2 - Volume of carbon dioxide (ml/kg/min)
时间窗: From enrollment to the end of treatment at 8 weeks
During all sessions, VO2 and VCO2 were measured using indirect calorimetry (CareFusion MasterScreen CPX) on an Ergoline Ergoselect 100/200 cycle ergometer. Data was averaged over 15-second intervals during all baseline and follow-up screenings and all training sessions. VO2 and VCO2 were also used to calculate respiratory exchange ratio (RER) during all sessions dividing the VCO2 by VO2.
Energy expenditure (L/min) via indirect calorimetry (CareFusion MasterScreen CPX).
时间窗: From enrollment to the end of treatment at 8 weeks
During all sessions, energy expenditure was measured using indirect calorimetry (CareFusion MasterScreen CPX). Data was averaged over 15-second intervals, and substrate utilization was calculated using standard formulas. * (GOR)- Oxidation rate of sugar (g/min): 4.585 × VCO2 (L/min) -3.2256 × VO2 (L/min) * (GO)- Oxidation amount of sugar (g): Oxidation rate of sugar × Time (min) * (FOR)- Fat oxidation rate (g/min): 1.695 × VO2 (L/min) -1.701 × VCO2 (L/min) ④ (FO)- Oxidation amount of fat (g): Oxidation rate of fat × Time (min) * (EER)- Energy consumption rate (kcal/min): 3.716 × VO2 (L/min) +1.332 × VCO2 (L/min) ⑥ (EE)- Energy expenditure (kcal): \[3.716 × VO2 (L/min) +1.332 × VCO2 (L/min)\] × Time (min)
Neuromuscular Electrical Stimulation (NMES) Protocol
时间窗: From enrollment to the end of treatment at 8 weeks
The NMES protocol was administered via a four-channel COMPEX SP4.0 (Medicompex SA, Ecublens, Switzerland) electric muscle stimulator using biphasic symmetric rectangular pulsed currents set at 300 μs. COMPEX self-adhesive electrodes were used during muscle stimulation with the COMPEX device. Positive snap electrodes (5×5 cm) with a membrane depolarization that stimulate a 25 cm2 area of the muscle surface were placed on the proximal insertion of vastus medialis and vastus lateralis. The other negative electrode (10×5 cm), measuring 50 cm2 was placed over the femoral triangle, 1-3 cm below the inguinal ligament.
Low-frequency Neuromuscular Electrical Stimulation (NMES)
时间窗: From enrollment to the end of treatment at 8 weeks
The low-frequency NMES protocol was administered via a four-channel COMPEX SP4.0 (Medicompex SA, Ecublens, Switzerland) electric muscle stimulator using biphasic symmetric rectangular pulsed currents set at 200 μs. Low-frequency NMES protocol was performed with a duty cycle of 20 seconds on (stimulating) and 20 seconds off (no stimulation) and the pulse width was set at 300 μs (warm-up frequency: 3 Hz, training frequency: 20 Hz, wave: square waveform) to the quadriceps muscle throughout 24 sessions. The duration of training was 30 minutes for sessions 1-6, 36 minutes for sessions 7-12, 42 minutes for sessions 13-18, and 48 minutes for sessions 19-24.
High-frequency Neuromuscular Electrical Stimulation (NMES)
时间窗: From enrollment to the end of treatment at 8 weeks
High-frequency NMES protocol was administered via a four-channel COMPEX SP4.0 (Medicompex SA, Ecublens, Switzerland) electric muscle stimulator using biphasic symmetric rectangular pulsed currents set at 300 μs. High-freqeuncy NMES protocol consisted of a 5-minute warm-up (65% VO2max) followed by a 1-minute exercise at 120% VO2max and then a 1-minute "loadless" cycling. This interval was repeated 8 times in sessions 1-6 and progressed to 14 repeated intervals by the 24th session. Participants also received an additional NMES treatment with a duty cycle of 12 seconds on (stimulating) and 8 seconds off (no stimulation) and a pulse width of 300 μs (training frequency: 45-60 Hz, wave: square waveform) to the quadriceps muscle throughout 24 sessions.
次要结局
未报告次要终点
研究者
Nasuh Evrim Acar
ASSISTANT PROFESSOR
Mersin University
