Evaluation of Plasma Volume Using Ultrasound in Disorders of Fluid With Sodium

Nagaoka Red Cross Hospital1 个研究点 分布在 1 个国家目标入组 42 人开始时间: 2012年2月最近更新:
适应症

试验速览

阶段
不适用
入组人数
42
试验地点
1
主要终点
Calculated CVP by using cardiac echogram

研究概览

简要总结

Rossi NF & Schrier RW reported that for having differential diagnosis in hyponatremic state, it is important to have a grasp of extra cellular fluid (ECF) volume. However, recent works showed that it is not easy to estimate the ECF state using by physical findings and by usual laboratory methods.

Damaraju SC et al. first demonstrated that measuring central venous pressure (CVP) is significant to evaluate the ECF state in hyponatremic patients with intracranial diseases. Accordingly, it may be useful to measure the CVP in the hyponatremic patients. However, usually it is difficult to measure the CVP in all patients with hyponatremia because that the method is due to invasive procedure. With recently development, it is possible to estimate the CVP calculation using cardiac echogram without invasion. However, it is not clear that an evaluation by using such echogram estimates the state of ECF volume in hyponatremic patients.

Therefore, the investigators examine whether the CVP calculation by using cardiac echogram by Marcelino P et al. method without invasion is estimated such condition in hyponatremic patients before and after treatments.

As the primary endpoint, the VCI index values is investigated and compared with each group before and after correction of disorders of fluid with sodium. Furthermore, some variables including sodium, potassium, chloride, creatinine, BUN, uric acid, osmolality in blood and urine and plasma vasopressin are investigated and compared with each group before and after correction of disorders of fluid with sodium.

详细描述

Calculated CVP value as VCI (vena cava inferior) index by Marcelino P et al. method-they reported that VCI index using several echocardiographic parameters measured. A transthoracic echocardiographic study was performed using an Aloka SSD 2200 echocardiograph fitted with 2.5MHz probe with continuous-wave,pulsed and color Doppler (Japan). Using pulsed Doppler,each parameter is measured as following; the deceleration rime of E wave of tricuspid inflow,the gradient between right ventricle (RV) and right atrium (RA) by continuous Doppler,the VCI variation from the corresponding maximum expiratory diameter (measured at 2 cm from the RA and in dorsal decubitus) to its diameter during inspiration. All measurements were taken at the end-expiration in order to standardize the samples. VCI index = [tricuspid E deceleration (ms)] x 0.11 + [RV/RA gradient (mmHg)] x 0.16 - [VCI variation (mm)] (VCI, vena cava inferior; tricuspid E, tricuspid E wave; RV, right ventricle, RA, right atrium).

Na, Cl, K, creatinine, BUN and uric acid in serum and urine were measured by the usual methods before and after the correction of plasma volume. Further, osmolality and vasopressin in plasma and osmolality in urine were also measured by the usual methods.

研究设计

研究类型
Observational
观察模型
Case Control
时间视角
Prospective

入排标准

年龄范围
18 Years 至 90 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients with disorders of fluid with sodium including cerebral salt wasting syndrome (CSWS), syndrome of inappropriate antidiuretic hormone secretion (SIADH), primary polydipsia (PP), central diabetes insipidus (CDI) and others
  • Patients more than 18 years old (gender is disregarded)
  • Healthy subjects more than 18 years old (gender is disregarded)

排除标准

  • Patients with a serious complication in the heart, liver or kidney
  • Pregnant or possibly pregnant patients, or lactating patients
  • Patients complicated with a malignant tumor at present.
  • Patients participating in other clinical study.
  • Other than the above, patients judged inappropriate as the subjects of this study by the investigator

结局指标

主要结局

Calculated CVP by using cardiac echogram

时间窗: within the first 30 days (plus or minus 3 days) after correcting status of plasma volume