跳至主要内容
临床试验/NCT06658366
NCT06658366已完成不适用

In Vivo Accuracy of Digital Intraoral Scans/Optical Impression Systems for the Production of Full-Arch Impressions

University of Zurich1 个研究点 分布在 1 个国家目标入组 10 人开始时间: 2024年10月28日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
10
试验地点
1
主要终点
Accuracy measurement of digital impressions performed with optical impression systems are primary endpoints

研究概览

简要总结

For several decades now, modern procedures have allowed dentists to capture your teeth using digital cameras. This digital procedure is increasingly replacing traditional impressions with a viscous mass that hardens in the mouth.

In the following study, the investigators want to find out whether the accuracy of these modern methods is comparable to the classic impression technique.

Three conventional impressions are taken for this purpose, and multiple digital impressions are also taken with each of the intraoral scanners. The impressions are then compared with each other. This allows the accuracy of the different intraoral scanners to be determined.

详细描述

In summary, this study intends to address the need for comprehensive in vivo research on the accuracy of intraoral impression methods, especially in the context of modern digital technologies. By comparing various digital and conventional methods, this research will offer valuable information to guide dental practitioners in choosing the most precise and reliable techniques for their clinical applications.

The following study design is planned:

The study is non-randomised. The study setup is monocentric. At the beginning of the session, 3 conventional impression each of the upper and lower jaw is taken. After 8 hours the impression is moulded by a dental technician with a SuperHard plaster (type 4).After 48 hours of setting time the plaster-model is scanned with a lab scanner (inEos X5, Dentsply Sirona) to generate a .stl-file that is comparable to the following digital impressions.

This is followed by 6 digital impressions of the upper and lower jaw and the associated bite registration in habitual occlusion, divided between two experienced practitioners (3 upper, 3 lower jaw scans, 3 bite registrations per practitioner) with the 8 different intra oral scanners. In total, 6 conventional (3 upper, 3 lower jaw impressions), 48 digital impressions and 48 bite registration are taken. If it is not possible to take all the impressions in one session, a new conventional impression is taken at the start of each new session, so that a daily updated reference model is always available. Minimizing bias is achieved, by using the intra oral scanners according to the manufacturers instructions.

The number of scans was calculated as part of a power analysis based on previous study results and should therefore be meaningful.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • All genders, minimum age for participation is 18 years
  • Good general health and healthy dental conditions (gaps with a maximum of 1 missing tooth are permitted)
  • Written consent after informed consent discussion is available

排除标准

  • participants under the age of 18
  • Addicts or participants with impaired cognitive abilities that do not allow the participant to assess the scope of the study
  • participants suffering from periodontitis (pathological tooth mobility could falsify the study results)
  • Maximal mouth opening less than 3.5 cm
  • participants who wear large reconstructive works and/or have a free-end situation from at least the 2nd premolar

研究组 & 干预措施

Comparison conventional impression vs. digital impression

Other

The investigators would like to investigate the accuracy of various intraoral scanning systems. For this a conventional impression is taken from all patients to generate a reference model, which is then compared to full-arch impressions from various digital intraoral scanning systems.

The examination is carried out in the same way for all participants.

干预措施: impression of the teeth (Diagnostic Test)

结局指标

主要结局

Accuracy measurement of digital impressions performed with optical impression systems are primary endpoints

时间窗: It is intended that all impressions take place within half a day, the accuracy measurement should be carried out within 6 weeks.

The accuracy of the intraoral scanners (primary endpoint) is analyzed on the basis of precision and trueness. The unit of measure used is the same (μm). The trueness of each test group is assessed by superimposing each scan with the reference model data set. The precision is calculated as the mean difference between all superimpositions within one test group.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验