跳至主要内容
临床试验/NCT04976907
NCT04976907Unknown不适用

Peri-operative Mobile Application for Contactless Screening and Vital Signs Measurement (MAC-VITAL): A Proof of Concept Trial

Nuralogix Corporation4 个研究点 分布在 1 个国家目标入组 200 人开始时间: 2021年10月1日最近更新:
适应症

试验速览

阶段
不适用
入组人数
200
试验地点
4
主要终点
Systolic blood pressure difference from reference measurement (mmHg)

研究概览

简要总结

The impact of the coronavirus disease (COVID)-19 pandemic on global healthcare systems has prompted a search for novel tools to stem the tide. New digital health tools can provide possible health solutions in this time of unprecedented medical crisis to mitigate the impact of this pandemic. This proof of concept study will determine the feasibility and effectiveness of implementing a mobile application for contactless screening and vital signs measurement (MAC-VITAL) such as blood pressure (BP), heart rate (HR), respiratory rate (RR), oxyhemoglobin saturation (SpO2), temperature from surgical patients peri-operatively. Contactless measurement of vital signs will bridge the current gap between virtual care and in-person medical assessments.

详细描述

This study aims to determine whether a mobile app can accurately and reliably measure vital signs without any person to person contact, and the feasibility of implementing it in a peri-operative setting (e.g., during COVID-19). The validity and feasibility of the Anura™ Research app will be assessed during inpatient visits in preparation for and after surgery, and it will be compared with standard medical monitors.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients scheduled to undergo elective surgery under general and/or regional anesthesia
  • 18+ years of age

排除标准

  • Refusal to consent for the study
  • Non-English speaking

结局指标

主要结局

Systolic blood pressure difference from reference measurement (mmHg)

时间窗: Perioperative

Assessed against standard clinical grade instrument: automated oscillometric blood pressure device (mmHg)

Diastolic blood pressure difference from reference measurement (mmHg)

时间窗: Perioperative

Assessed against standard clinical grade instrument: automated oscillometric blood pressure device (mmHg)

Blood oxygenation (SpO2) difference from reference measurement (% oxyhemoglobin saturation)

时间窗: Perioperative

Assessed against standard clinical grade instrument: Finger-based pulse oximeter (% oxyhemoglobin saturation)

Pulse rate difference from reference measurement (beats per minute)

时间窗: Perioperative

Assessed against standard clinical grade instrument: Finger-based pulse oximeter (beats per minute)

Teperature difference from reference measurement (degrees Celsius)

时间窗: Perioperative

Assessed against standard clinical grade instrument: Forehead digital thermometer (degrees Celsius)

Respiratory rate difference from reference measurement (breaths per minute)

时间窗: Perioperative

Assessed against standard clinical grade instrument: Visual count of chest rise and fall (breaths per minute)

Obstacles to using the mobile application

时间窗: Perioperative

Characterization of obstacles to the implementation of the mobile app for perioperative vital sign measurements.

次要结局

  • Detection rate of clinically meaningful changes of vital signs(Perioperative)
  • Ease of use survey(Perioperative)
  • Satisfaction survey(Perioperative)
  • Study participation(Perioperative)
  • Compliance with measurement protocol(Perioperative)