跳至主要内容
临床试验/NCT02537769
NCT02537769招募中不适用

Randomized Study of the Clinical Impact of Surgical Correction of Tricuspid Insufficiency in Implantable LVAD Patients

University of Washington1 个研究点 分布在 1 个国家目标入组 40 人开始时间: 2015年8月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
招募中
入组人数
40
试验地点
1
主要终点
Change in TR severity assessment from baseline

研究概览

简要总结

The use of implantable left ventricular assist devices (LVAD) has increased over the last decade; partly because the newer continuous flow pumps feature a smaller design and better durability. These pumps have shown improved outcomes for those patients who don't qualify for heart transplantation and receive the LVAD device as a permanent therapy or a bridge to heart transplantation. Despite these improved outcomes, procedure related length of hospitalization for LVAD implantation is still 2 or 3 times that of other heart surgery treatments. One important reason for this is that many people experience right ventricular dysfunction after LVAD implantation. Treatment options for this are limited. Many LVAD patients with right ventricular dysfunction also have tricuspid valve regurgitation (TR). This is the failure of the tricuspid valve (TV) to close completely so that blood leaks backwards. Some recent studies suggest that correction of the TV during LVAD implantation has improved survival for those with severe regurgitation. However, this has not been evaluated for mild or moderate regurgitation.

The goal of this study is to look at the clinical impact of surgical correction of mild to moderate TR in participants who are also undergoing LVAD implantation. The study will look at the degree of TR at various time points post-surgery, as well as any major cardiac adverse events, duration of hospitalization, and quality of life. The investigators hope to show that surgical correction of mild to moderate TR in LVAD patients will reduce right ventricular dysfunction and have a positive impact on health outcomes.

详细描述

Participant recruitment: At University of Washington Medical Center, 30 to 40 patients with mild tricuspid valve regurgitation (TR) receive LVAD placement annually. A predicted 50 - 60% of these patients will agree to be enrolled in this study, for an estimation of 15 to 20 participants a year. With an enrollment period of 2 years, the study aims to enroll 30 to 40 participants

Study interventions and Specific Techniques: Prior to screening data collection and protocol defined procedures, the participant must sign the consent form. Within 30 days prior to randomization (as part of routine clinical care), a complete transthoracic echocardiogram will be performed, evaluated, and reported. Within 7 days prior to randomization (as part of routine clinical care): 1) a medical history and physical exam is performed; 2) New York Heart Association (NYHA) and Canadian Cardiovascular Society (CCS) Classes are established and documented; 3) all current medications and therapies are recorded on study documents; 4) the participant will complete the Duke Activity Status Index for quality of care (QOL) assessment.

Randomization: Randomization procedure will be performed intra-operatively, following sternotomy and before cannulation of aorta. Randomization will follow a computer generated simple randomization process. Participants will be randomized with equal probability to receive LVAD implantation alone or LVAD implantation plus surgical repair of their tricuspid valve (TV). The nature of the treatments precludes masking of participants and their treating clinicians to treatment assignment.

Surgical technique: Participants randomly assigned to receive tricuspid valve repair (TVR) in addition to LVAD implantation will undergo repair with standard techniques. After bicaval cannulation and with the heart beating, a right atriotomy is created and the TV exposed. A patent foramen ovale (PFO), if present, is closed primarily. 2-0 braided sutures are placed radially through the tricuspid annulus from the lateral fibrous trigone counterclockwise to the medial fibrous trigone, thus avoiding the conduction system. An incomplete semi-rigid annuloplasty ring is then suspended after appropriate sizing. Any ventricular pacing leads are then mobilized from leaflet and subvalvular adhesions and placed in the commissure between the septal and posterior leaflets. The septal and posterior leaflets are then approximated from the junction of the rough and smooth zone back to the leads, bicuspidizing the valve, and trapping the ventricular leads away from the tricuspid valve orifice.

Tricuspid valve assessment: The 3 leaflets of the TV will be assessed with echocardiography. The midesophageal inflow-outflow view and the midesophageal modified bicaval TV view will be chosen for Doppler interrogation of transvalvular flow. 3D examinations will also be assessed. 3D Transesophageal echocardiography (TEE) permits the precise description of the elliptical shape of the TV annulus and its dimensions in a clinically feasible fashion.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Single (Outcomes Assessor)

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Participant or their legal representative has signed an informed consent
  • •Over 18 years of age
  • •Participant with advanced heart failure symptoms (Class III or IV) and preoperative mild tricuspid regurgitation who are scheduled for an implantable LVAD

排除标准

  • •Prior tricuspid valve repair
  • •Any evidence of structural (chordal or leaflet) tricuspid valve disease
  • •Technical obstacles, which pose an inordinately high surgical risk, in the judgment of the investigator
  • •Existence of any ongoing mechanical circulatory support other than intra-aortic balloon counter pulsation
  • •Body Mass Index (BMI) > 45
  • •Presence of mechanical aortic valve that will not be converted to a bioprosthesis at time of LVAD implant
  • •History of cardiac transplant or cardiomyoplasty
  • •Psychiatric disease, irreversible cognitive dysfunction or psychosocial issues that are likely to impair compliance with the study protocol and LVAD management
  • •Presence of active, uncontrolled infection
  • •Evidence of intrinsic hepatic disease as defined by liver enzyme values
  • •History of a stroke within 90 days prior to enrollment, or a history of cerebral vascular disease with significant (> 80%) extra cranial stenosis
  • •Need for chronic renal replacement therapy (e.g. chronic dialysis)
  • •Participation in any other clinical investigation that is likely to confound study results or affect study outcome
  • •Any condition, other than heart failure, that could limit survival to less than 1 year
  • •Participant refuses to be enrolled in study
  • •Institution inmates.

研究组 & 干预措施

LVAD+TVR

Experimental

In addition to left ventricular assist device (LVAD) placement with the inflow cannula in the left ventricular apex and outflow cannula placed in the ascending aorta, a repair of the regurgitating tricuspid valve will be performed. A Patent Foramen Ovale, if present, will be closed primarily. Echocardiographic parameters relevant to study will be collected throughout the procedure.

干预措施: Left ventricular assist device (LVAD) (Device)

LVAD+TVR

Experimental

In addition to left ventricular assist device (LVAD) placement with the inflow cannula in the left ventricular apex and outflow cannula placed in the ascending aorta, a repair of the regurgitating tricuspid valve will be performed. A Patent Foramen Ovale, if present, will be closed primarily. Echocardiographic parameters relevant to study will be collected throughout the procedure.

干预措施: Tricuspid Valve Repair (TVR) (Procedure)

LVAD only

Active Comparator

LVAD placement will be performed without additional tricuspid valve repair (TVR). The inflow cannula will be sutured to the left ventricular apex followed by the outflow cannula placed in the ascending aorta. This will be performed under cardiopulmonary bypass. Echocardiographic parameters relevant to study will be collected throughout the procedure.

干预措施: Left ventricular assist device (LVAD) (Device)

结局指标

主要结局

Change in TR severity assessment from baseline

时间窗: 13 months

Tricuspid Regurgitation (TR) severity as measured by vena contracta width and area will be assessed using echocardiography within 7 days prior to implantation (baseline) up to 13 months postoperative. TR severity is assessed on a range of mild to severe.

次要结局

  • Change in quality of life (QOL) from baseline(13 months)
  • Change in RV function from baseline(13 months)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Kei Togashi

Assistant Professor, Division of Cardiothoracic Anesthesiology

University of Washington

研究点 (1)

Loading locations...

相似试验