Low Energy in Atrial Fibrillation AF Phase IV Study in AT/AF Population Atrial Arrhythmias Prevention and Reduction With Low Energy Atrial Antitachycardia Pacemaker
试验速览
- 阶段
- 4 期
- 状态
- 已完成
- 发起方
- 入组人数
- 237
- 主要终点
- Demonstrate that AT 500 algorithms decrease AF Burden
研究概览
简要总结
The purpose of the study is to demonstrate the efficiency on AT / AF prevention and termination of a new algorithm contained in the Medtronic AT500 Antitachycardia device in patients with conventional pacemaker indications.
详细描述
Aim. More than 30% of patients (pts) implanted with a pacemaker are known to have atrial tachyarrhythmias (AT) despite medical treatment and about 20% of pts experience AT prior to implant. The Medtronic AT500TM is a new DDDRP pacemaker with extended memory and features designed for preventing and terminating AT. The objective of this European multi-center prospective crossover and randomized study is to evaluate efficacy of this device for decreasing AT burden, improving QOL and reducing symptoms and costs. Method. 243 pts are implanted with the AT500TM and followed at 1, 7 and 13 months after implant. All patients are selected for a dual chamber pacemaker indication plus at least two episodes of AT in the last 12 months. One month after implantation patients are randomized either to a six month therapy phase (activation of preventive and ATP pacing) or a six month observation phase (No AT prevention nor Therapy). Crossover (CO) takes place at seven months after implant and the endpoint is reached at 13 months. Symptom checklist and QOL questionnaires are completed by pts at enrollment and after the two randomization periods. At each follow-up, a Save to Disk (STD) of device-stored AT episodes is performed and hospitalization, visits and/or other examinations are reported for future cost evaluation.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Crossover
- 主要目的
- Treatment
- 盲法
- Single
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •ACC/AHA Class I or II indication for dual chamber pacing and two symptomatic atrial fibrillation or flutter episodes in the three months prior to implant as well as ECG documentation of at least one episode in the prior year.
排除标准
- •Patients with permanent/persistent AF, an indication for an implantable cardioverter defibrillator or class IV heart failure.
结局指标
主要结局
Demonstrate that AT 500 algorithms decrease AF Burden
次要结局
- Characterize the efficiency of prevention and termination algorithms on the Quality of Life of patients
- Characterize the correlation between symptoms and stored EGM's
- Determine the total number of AF/AT episodes and observe the decrement of their occurrence frequency due to prevention algorithms.
- Determine the number of Hospitalization, physician visits…: economical analyze
- Analyze the episode onset mechanism