Validation of Electrocardiogram Waveform, Heart Rate Accuracy and Arrhythmia Diagnosis Concordance in Patients With Cardiac Arrhythmia Using Single-channel ECG Monitoring Patch and Holter Monitoring

Mezoo Co., Ltd.2 个研究点 分布在 2 个国家目标入组 105 人开始时间: 2023年2月8日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
105
试验地点
2
主要终点
Comparison of arrhythmia diagnosis concordance rates between patch-type electrocardiograph and commercial Holter device measurement data by arrhythmia categories

研究概览

简要总结

This study will verify the 1-channel patch-type ECG's arrhythmia diagnostic concordance rate and electrocardiogram measurement performance by collecting ECG signals from patch-type ECG and Holter device simultaneously for data analysis.

详细描述

[How to conduct research] This study targeted adults aged 19 years or older. Written consent is obtained from those who are diagnosed with arrhythmia and need a Holter examination among outpatients or inpatients at the Cardiology Department of Kosin University Gospel Hospital. The medical staff attaches the Holter device to the subject and the patch-type electrocardiograph in the Holter examination room. Holter device and patch-type electrocardiograph are returned to the Holter examination room after measuring the electrocardiogram for 24 hours. ECG signals from patch-type electrocardiographs and commercial Holter device and arrhythmia detection information are compared and analyzed.

[Number of Subjects] The number of this study is 105. Written consent is obtained from those who are diagnosed with arrhythmia and need a Holter examination among outpatients or inpatients at the Cardiology Department.

[Data analysis plan] In this study, the personal identification information of the subjects will be coded non-identifying and the collected electrocardiogram data will be stored in the cloud with restricted access from outsiders. Coded, non-identified research data is stored and managed in the cloud in compliance with privacy standards and information security standards. ECG data transmitted through the mobile application is stored in the cloud. Confidentiality and security of data are guaranteed, and data collected from patch-type electrocardiograph is used only for research. The electrocardiogram data acquired in this study are obtained in TXT or MAT format and used for data analysis.

The efficacy evaluation items are as follows.

  1. Comparison of ECG signal concordance
  2. Comparison of the parameters below for a noise-free section of about 1 minute, not the entire section

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
19 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Adults 19 years of age or older
  • Patients who are diagnosed with arrhythmia and need regular Holter electrocardiography among outpatients or hospitalized patients at the Department of Cardiology, Kosin University Gospel Hospital
  • Those who gave written consent to this clinical study
  • Able to understand and carry out training and instructions

排除标准

  • A person with a physical disability that cannot wear a patch-type electrocardiograph
  • A person suffering from skin disease or functional disorder at the site where the patch-type electrocardiograph will be attached
  • Subjects who cannot read the consent form (illiterate, foreigners, etc.)
  • Patients judged to be unsuitable for participation in this clinical study by the judgment of investigators

结局指标

主要结局

Comparison of arrhythmia diagnosis concordance rates between patch-type electrocardiograph and commercial Holter device measurement data by arrhythmia categories

时间窗: Within 3 months after electrocardiogram procedure

Comparison of arrhythmia diagnosis concordance rates between 24-hour patch-type electrocardiograph and commercial Holter device measurement data by arrhythmia categories(total of 19 including ventricular ectopic beat)

Comparison of ECG signal concordance between patch-type electrocardiograph and holter device

时间窗: Within 3 months after electrocardiogram procedure

Calculate the concordance (%) of the ECG signal by comparing and analyzing total QRS complex, total ventricular ectopic beat, total atrial ectopic beats, minimum heart rate, maximum heart rate, average heart rate and maximum RR interval

次要结局

未报告次要终点