临床试验/NCT05888246
NCT05888246已完成不适用

Measuring the Range of Cardiac Magnetic Parameters in Healthy Subjects by Magnetocardiogram: a Prospective, Observational Clinical Study

Hangzhou Nuochi Life Science Co., Ltd.1 个研究点 分布在 1 个国家目标入组 412 人开始时间: 2022年5月7日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
412
试验地点
1
主要终点
Maximum current vector angle (MCV angle)

研究概览

简要总结

A prospective and observational clinical study of measuring the range of cardiac magnetic parameters in healthy people with the magnetocardiogram manufactured by Hangzhou Nuochi Life Science Co., LTD

详细描述

This study is a prospective and observational study on the collection of cardiac magnetic signals from healthy subjects by magnetocardiogram. It is expected that 412 subjects will be examined by magnetocardiography, and the range of parameters related to magnetocardiography in healthy subjects will be reported.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 70 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Healthy people aged 18-70 years old;
  • Subjects receiving physical examination in physical examination institutions, or in other departments other than heart disease (such as orthopedics, gynecology, etc.), or in cardiology department, excluded from coronary heart disease;
  • No history of coronary heart disease;
  • ECG did not indicate myocardial ischemia or infarction;
  • Sinus rhythm without arrhythmia;
  • The subject or the subject's legal representative has been informed of the nature of the study, understands the purpose of the clinical study, voluntarily participates in the study and signs the informed consent.

排除标准

  • Acute coronary syndrome requires emergency PCI treatment, and it is estimated that magnetic cardiogram examination will affect the timing of emergency PCI surgery;
  • Subjects with metal implants in the thoracic cavity (including the heart cavity), such as those who have received pacemaker therapy or cardiac resynchronization therapy (CRT, CRT-D) or implantable cardioverter defibrillator (ICD) implantation, or those who have received metal heart valve implantation;
  • There is hemodynamic instability, which is defined as systolic blood pressure < 80mmHg, or cardiogenic shock; Or need vasoactive drug therapy; Intra-aortic balloon counterpulsation may be required; Or other hemodynamic support devices; As syndrome;
  • Severe tachycardia (ventricular rate > 150 beats/min), ventricular flutter, ventricular fibrillation and other malignant arrhythmias;
  • Subjects unable to lie flat (supine position);
  • Subjects with mental illness, unconscious or uncontrollable ability; Or claustrophobic subjects;
  • Other circumstances in which the investigator considers the subject inappropriate for participation in the study

结局指标

主要结局

Maximum current vector angle (MCV angle)

时间窗: 24 hours

The Angle of the maximum current vector was measured at the vertex of QRS and T wave respectively.

PR interval

时间窗: 24 hours

PR interval is defined as the position from the starting point of P wave to the starting point of QRS wave after the superposition of 36 channels in the magnetocardiogram (butterfly diagram).

QT interval

时间窗: 24 hours

QT interval is defined as the time (ms) from the beginning of Q wave to the end of T wave after the stacking of 36 channels in the magnetocardiogram (butterfly diagram).

The magnetic field intensity parameter (R/T ratio)

时间窗: 24 hours

The magnetic field intensity parameter (R/T ratio) is defined as the ratio of the maximum magnetic field intensity of the r-wave vertex to the T-wave vertex of the magnetocardiogram calculated based on the isomagnetic map.

QRS interval

时间窗: 24 hours

QRS interval is defined as the time (ms) from the beginning of QRS to the end of QRS after the stacking of 36 channels in the magnetocardiogram (butterfly diagram).

Corrected QT interval

时间窗: 24 hours

The corrected QT interval was defined as the QTC interval (ms) after the stacking of 36 channels in the magnetocardiogram (butterfly diagram). QTc = QT/(RR\^0.5), RR is the average RR interval calculated by cardiac magnetic waveform, QT is QT interval.

Maximum current vector amplitude (MCV amplitude)

时间窗: 24 hours

The amplitude of the maximum current vector was measured at the vertex of QRS wave and T wave respectively.

Total current vector angle (TCV angle)

时间窗: 24 hours

TCV represents the total current vector, which is the sum of all current vectors of 36 channels in the magnetocardiogram. First calculate the vector sum of the 36 channels, and finally calculate the angles.

Total current vector amplitude (TCV amplitude)

时间窗: 24 hours

TCV represents the total current vector, which is the sum of all current vectors of 36 channels in the magnetocardiogram. First calculate the vector sum of the 36 channels, and finally calculate the amplitude.

次要结局

未报告次要终点

研究者

申办方类型
Industry
责任方
Sponsor

研究点 (1)

Loading locations...